1 Pressure System Amanda Newman Andy Patel Bryan Cuervo September 28 th 2005 ENGR. 329 UTC Engineering

2 Outline of The Presentation Background of the Pressure system SSOC (Steady State Operating Curve) Step response analysis FOPDT Parameters Step response FOPDT Model Comparing Experimental vs. Model Conclusions and suggestions

3 Background of Pressure System

4 Pressure System Schematic

5 Block Diagram for the system

6 Lower Range Middle Range Upper Range

7 Suggested Operating Range SSOC –Non-linear –1-10 cm-H2O Operational output range –50%-100% Operational input range –Slope differs for different operating ranges

8

9

10

11

12

13 The FOPDT Parameters are: K = Gain t 0 = Dead time T(tau)= Time constant A = Size of the Step Td = Time at which the step occurs Inbl = Input Baseline Outbl = Output Baseline

14 Experimental FOPDT Parameters are: Gain, K: 0.109 cm-H 2 0 Dead time, t o : 0.480 Time constant, Tau: 2.016

15

16

17

18

19

20 Model FOPDT Parameters are: Gain, K: 0.110 cm-H 2 0 Dead time, t o : 0.725 Time constant, Tau: 2.056

21

22

23

24 Conclusions Found the Model FOPDT parameters and compared them to the experimental FOPDT parameters Found that the GAIN and TAU were very similar, but t o differed a lot. Ideal operation input range is: 5%-100%