1 11 CSC DQA Status Ken Johns, Venkat Kaushik, Caleb Lampen, Xiaowen Lei (U. Arizona)

2 22 CSC Status  CSC performance is stable and in good shape

3 33 CSC Online DQA  CSC GNAM CSC GNAM, OHP, DQMF, COOL flags running reliably CSC GNAM recently changed to Reset at Warm Start  Will likely change to Reset at First Warm Start and Fill When Ready after This option is available in gnam-05-01-05 Will change once this patch is installed at P1  CSC GNAM using Calib Stream Developed and tested offline and now runs regularly online To-do: define and fill histograms more specific to Calib Stream

4 44 CSC Online DQA  Segment monitoring histograms from Calib Stream Nice online histograms for clusters and segments can be produced from Calib Stream, which is rich in muons Will take advantage of this to monitor CSC reconstruction performance, etc

5 55 CSC Offline DQA  CSC RawDataMonitoring CSC Tier0, HAN, DQMF, COOL running reliably Used for SHFTOFL flags In progress,  PRD, Cluster monitoring being moved to the ESD-AOD xform (T. Kittelmann)  Segment monitoring tested but needs tag for Tier0  Post-processing monitoring (efficiencies, Laudau mpv, etc.) tested but needs tag for Tier0  CSC-TGC correlation monitoring just starting

6 66 CSC Offline DQA  History plots We also developed software to web display user specified Tier0 histograms for user specified run numbers

7 77 CSC Calibration Center Monitoring  CSC Calibration Center (CC) monitoring software is being resurrected CSC data should be again included in the Calibration stream  Verified OK Processing at the CC needs to be (re)validated  Verified OK Next steps are  Addition of needed variables into the ROOT ntp  Software development to cross-check electronic calibration constants using CC root-tuple is in progress Thanks to A. Di Mattia and F. Petrucci for first two items

8 88 Pedestal and Electronic Calibration Monitoring  Pedestal monitoring in place (C. Lampen) Automatically generates monitoring web pages  Pedestal values  Pedestal RMS  χ 2 of pedestal Gaussian fit  Attempts to highlight noisy channels and deviations from nominal values  In development: COOL based historical survey of pedestal runs