Download presentation
Presentation is loading. Please wait.
1
6 June 2002UK/HCAL common issues1 Paul Dauncey Imperial College Outline: UK commitments Trigger issues DAQ issues Readout electronics issues Many more questions than answers!
2
6 June 2002UK/HCAL common issues2 UK commitments The CALICE-UK groups have bid for funding to do: Physics prototype ECAL readout electronics –This might be reusable for tile HCAL but we are short on engineering effort for major extra work Physics prototype general data acquisition (DAQ) system –This must include control of the trigger, but we will not have funding for the trigger itself We will hear if funded in ~ three weeks (1 July)
3
6 June 2002UK/HCAL common issues3 Why am I at an HCAL meeting? We are currently writing specifications for the UK items: http://www.hep.ph.ic.ac.uk/~dauncey/lc/specification.ps To complete this, we need to know: What are the HCAL interactions with the trigger? What are the HCAL interactions with the DAQ? Are there small changes we can make to the readout electronics to enable it to work easily with the tile HCAL? The answers may already be known: If so, please direct us to the documentation! If not, can we make decisions soon?
4
6 June 2002UK/HCAL common issues4 Trigger: latency What is the allowable latency of the trigger? The ECAL needs the sample-and-hold to be timed to coincide with the shaped pulse peak at 180ns after the event What are the corresponding numbers for the two HCAL options? –How sensitive is the timing? –Where will the timing be adjusted? –Will it vary channel-to-channel?
5
6 June 2002UK/HCAL common issues5 Trigger: distribution What inputs from the trigger are needed? Will trigger distribution to the whole of the HCAL be done within its electronics? –If not, how many input trigger lines are needed? –What signal level will they be; LVDS? Will the HCAL allow a trigger to be aborted? –Required in ECAL if second particle arrives within ~ 100ns –Will HCAL electronics be retriggerable without readout?
6
6 June 2002UK/HCAL common issues6 Trigger: calibration Is there HCAL front-end circuitry for a calibration signal? How will selection of this be done? –Trigger must be switched to calibration mode Is timing identical for calibration and real events? –ECAL may need different times to the sample-and-hold between the calibration pulse and real events due to change of pulse shape –Is this true for the HCAL? If so, where will the adjustment be made?
7
6 June 2002UK/HCAL common issues7 DAQ: event sizes What are the expected data sizes? ECAL will not be threshold-suppressed –9720 channels with 16 bits every event ~ 19 kBytes What are the corresponding numbers for the HCAL options? –? Tile HCAL is up to 1200 channels, each 16 bits, so total ~ 2 kBytes –? Digital HCAL is up to 38 layers, 10k channels/layer, total 380k channels, each 1 bit ~ 50 kBytes Will the HCAL have threshold suppression? –If so, what are the expected number of channels to read out?
8
6 June 2002UK/HCAL common issues8 DAQ: event numbers What are the requirements for numbers of events? What event rate is needed for the DAQ? –We assume 100Hz is adequate, 1kHz is prefered What is the total number of events needed? –We assume ~ 10 6 events per set-up (i.e. energy, particle type, etc.) –We assume between 10 and 100 set-ups (? e.g. what range of energies are needed?) giving 10 7 to 10 8 events total –Total sample of 10 8 events at 100Hz is 10 6 secs or 2 weeks actual running time
9
6 June 2002UK/HCAL common issues9 DAQ: electronics What is the readout interface? ECAL will be purely VME –Crate controller, trigger board and 15 readout boards occupy 17 slots of 21 slot crate Can HCAL be made VME also? –If so, then how many slots are needed? If HCAL can fit into four slots, only one crate needed –If not, a VME accessible interface (e.g. from CAMAC) will need to be supplied
10
6 June 2002UK/HCAL common issues10 DAQ: other issues What is the output data format? –Needs to be machine-independent and easy to use –We suggest ROOT-based files Are we restricted by a 2 Gbyte file size limit? –Older operating systems will not deal with bigger files –Older ftp will not transfer bigger files –With digital HCAL, this is only ~30k events, i.e. 5 minutes of running
11
6 June 2002UK/HCAL common issues11 Readout electronics Can ECAL readout boards be used for tile HCAL? (We assume digital HCAL is too different…) Interface is through 36-pin connector –18 signals, –Mixed analog and digitial –All differential Not yet completely defined –Still time for changes Each ECAL readout board handles 6 cables –Identical signals on all 6 –Total of 15 boards, 90 cables in system
12
6 June 2002UK/HCAL common issues12 Connector signals
13
6 June 2002UK/HCAL common issues13 ECAL VFE ECAL Very Front End (VFE) chip handles 18 channels –Serial readout using a shift register –All shift register logic controlled by FPGA on readout board; can be made flexible, e.g. number of clocks –What is readout scheme for tile HCAL? Is it multiplexed? Is it compatible with these connectors? Analog channel output digitised using (we hope!) 16- bit ADCs –Maybe 14-bit if cannot find fast enough components –Voltage range not yet specified; what is range for tile HCAL? Mounting different level converters would be possible if we can find compatible components
14
6 June 2002UK/HCAL common issues14 Conclusions Many unknowns (to us) which need to be determined before we can finalise the specifications Schedule for first readout board prototype is early 2003 –Need ~ 6 months to design (from scratch) –Need answers to questions within ~ 1 month We will try to retain maximum flexibility –But difficult if significant cost or effort
Similar presentations
© 2024 SlidePlayer.com. Inc.