Download presentation
Presentation is loading. Please wait.
1
Model-based detection of event- related signals in electrocorticogram Jeffrey A. Fessler, Se Young Chun EECS Department Jane E. Huggins, Simon. P. Levine Dept. of Physical Medicine and Rehab., and Biomedical Engineering The University of Michigan, Ann Arbor, MI NIPS BCI Workshop, 2004-12-17
2
UM-DBI Project The University of Michigan Direct Brain Interface (UM-DBI) project seeks to detect voluntarily produced electrocortical activity (ECoG) related to actual or imagined movements in humans as the basis for a DBI.
3
Signal Source Subdural implantation Location selected for epilepsy monitoring, not necessarily on motor cortex Macro electrodes 4 mm diameter 1 cm center-to-center Grids and/or strips 4 - 126 electrodes
4
ECoG Data Subjects perform about 50 repetitions of up to 6 different (real) voluntary actions. Events (unprompted) separated by 3 to 10 seconds Action marked by EMG signal (partial labeling). No feedback or training. 10,000+ ECoG traces (not all useful)
5
Initial Detection Method Data: sampled ECoG signals from a single electrode Detection of event-related potentials (ERPs): Cross-correlate ECoG signal with a signal template Template: triggered average of training data Compare output to an empirical threshold Cross-Correlation based Template Matching (CCTM)
6
ERP Template Example ECoG signals from 5 events Average of 23 events (ERP template)
7
Cross Correlation Method: Its Implicit Model Two hypotheses for an ECoG signal block x: H 0 : x ~ N(0, 2 I)“rest” H 1 : x ~ N( , 2 I)“task/event” where denotes the template signal vector Neyman-Pearson optimal detector, under the above model, formed from the likelihood ratio, is x ’ which is cross correlation (CCTM). But the “white noise” signal model ignores changes in the signal power spectrum!
8
Power Spectrum Changes The ECoG signal spectrum changes during tasks. Event-related desynchronization (ERD) and event-related synchronization (ERS) (ERD/ERS maps from B. Graimann et al, Graz)
9
Concurrence of ERP and Spectral Changes
10
Moving-window spectra Time “0” is the event trigger times. The power spectrum changes significantly near event onset.
11
Power Spectrum Changes Short-time power spectrum minus baseline power spectrum
12
Moving-window Spectra (Individual events) Spectral changes are evident even in single events!
13
Spectrum-Based Detection Strategies Feature based: Extract spectral signal features e.g., band power, adaptive AR methods (Graz) Apply feature-based detection (e.g., LDA) Model based: Develop “optimal” detector based on signal models that attempt to capture key signal characteristics.
14
Quadratic Detector based on Two-Covariance Signal Model Two hypotheses for the ECoG signal (block) x: H 0 : x ~ N(0, K 0 )“rest” H 1 : x ~ N( , K 1 )“task/event” where K n denotes the covariances in each state Neyman-Pearson optimal detector, formed from the likelihood ratio, is: x’ (K 0 -1 - K 1 -1 ) x which is a quadratic detector (cf Mahalanobis distance). (For now, ignore the ERP component
15
Challenges / Solutions Large covariance matrices => many model parameters? Solution: AR spectrum model (about 6th order) AR models (non-adaptive) for K 0 and K 1 estimated from training data. Unprompted events => incompletely labeled data. Solution: joint maximum-likelihood (ML) estimates of labels and AR coefficients from training data. Inversion of large covariance matrices? Solution: simple FIR filters due to AR model.
16
Quadratic Detector Block Diagram Two FIR filters (AR inverse) Moving sum-of-squares (innovation power) Normalize by ML estimates of variances Compare “which model fits better” Neyman-Pearson => most powerful (per block)
17
Feature-based vs Model-based Spectra of simulated signals: H0H0 H1H1
18
ROC from Simulation Quadratic Band-power AAR / LDA
19
Test Data & Results Representative subset of 20 data sets from 10 subjects 2184 ECoG channels Evaluate in terms of “HF difference” % of “hits” (a detection within an acceptance window) minus % of false detections. ROC evaluation seems infeasible due to unprompted actions / incompletely labeled data.
20
Quadratic vs CCTM: 1 sec Delay
21
Quadratic vs CCTM: 0.5 sec Delay ECoG channels above each HF-difference threshold
22
Detection Delay Important for feedback!
23
Summary Quadratic detector Based on two-covariance model. Captures spectral changes. Simple real-time implementation. Improved detection accuracy over CCTM. Reduced detection delay. Recently implemented in our real-time system. Feedback studies with imagined movements forthcoming.
24
Future work Combine two-covariance model with ERP component? Three-covariance model? (ERD / ERS / rest) Time-varying / adaptive models state space / hidden Markov in collaboration with Victor Solo Extend to multi-channel detection methods Integrate into real-time use for feedback studies Imagined movements (in progress)
25
Extra slides
26
Average ECoG from 32 electrode locations during pinch Triggered ECoG Averages
27
CCTM Detection Cross-correlate ERP template and ECoG Detection: Correlation value exceeds an empirical threshold Hit: Detection between 1.0 sec before and 0.25 sec after a trigger Results quantified by Hit% - False Positive % (HF-difference) Template Continuous ECoG Cross-Correlogram
28
Single Channel Detection Hit % and False % for best channel in each data set (Average method, top 50 data sets for 18 subjects )
29
ML Estimates of Labels Estimate center and width of “task” intervals using log-likelihood under two-covariance model. (Requires search over center / width.)
30
ML labels vs MSE labels Joint ML approach to labeling data yielded comparable performance to previous heuristic MSE approach.
31
Detection Delay (not sure about this data from JV)
32
Moving-window spectra Time “0” is the event trigger times. Clearly the power spectrum changes near event onset. (Visible even in single event moving-window spectra.)
Similar presentations
© 2024 SlidePlayer.com. Inc.