The Compendium of formulae of kick factor. PLACET - ESA collimation simulation. Adina Toader School of Physics and Astronomy, University of Manchester & Cockcroft Institute, Daresbury Laboratory The University of Manchester
2
Round CollimatorRectangular Collimator Introduction z z Geometric wakefields are those who arise from a change in the vacuum chamber geometry. The geometric wake of a collimator can be reduced by adding a longitudinal taper to the collimator which minimizes the abruptness of the vacuum chamber transition. PLACET is useful tool for simulating rectangular aperture spoilers.
3
Introduction is either small or large compared to1. For a high energy beam passing through a symmetric collimator at a vertical distance y (y << b 1 ) from the axis, the mean centroid kick is given by: where N is the number of particles in the bunch, γ is the relativistic factor, r e is the classical electron radius, y is the bunch displacement and k is the (vertical) kick factor – transverse kick averaged over the length of the beam. Analytical formulas for the kick factor can be found in the limits where the parameter
4
Inductive regime Tenenbaum[2] gives: Zagorodnov[3] gives: Tenenbaum[6] gives for a round collimator of half-gap r and tapered angle α: Round Collimator
5
Stupakov[1] gives: Tenenbaum[2] gives, -for a long, round collimator: -for a short, round collimator: Diffractive regime - analytical formulas exits in the limit of short (L→0) and long (L→∞) collimator Tenenbaum[6] gives for a round collimator of half-gap r and tapered angle α: Round Collimator
6
Rectangular Collimator is either small or large compared to1. Analytical formulas for the kick factor can be found in the limits where the parameter
7
Inductive regime Tenenbaum[2] gives: Zagorodnov[3] gives: Tenenbaum[6] gives for a rectangular collimator of half-gap r and tapered angle α: Rectangular Collimator PLACET
8
Stupakov[1] gives: Zagorodnov[3] gives, -for a long collimator (L→∞): -for a short collimator (L→0): Diffractive regime Tenenbaum[6] gives (r ≡ b 1 ) Rectangular Collimator Tenenbaum[2] gives, for a short, flat collimator on the limit b 1 « b 2 : PLACET
9
Stupakov[1] gives: Tenenbaum[2] gives, Intermediate regime Tenenbaum[6] gives: Rectangular Collimator Zagorodnov[3] gives: with A=1 for a long collimator (L→∞) and A=1/2 for a short collimator (L→0). PLACET
10
ESA Collimators h=38 mm 38 mm L=1000 mm r=1/2 gap 1 1 2 2 3 3 6 6 α = 324mrad r = 2 mm α = 324mrad r = 1.4 mm α = 324mrad r = 1.4 mm α = 166mrad r = 1.4 mm α = 324mrad r = 2 mm α = 324mrad r = 1.4 mm α = 324mrad r = 1.4 mm α = 166mrad r = 1.4 mm Collimator Side view Beam view
11
Kick Factors for ESA Collimators Bunch size, σ z =0.5 mm Coll Kick Factors (V/pC/mm) PLACET Analytic Prediction * Measured * 1 2.47 2.27 1.4±0.1 (1.0) 2 5.04 4.63 1.4±0.1 (1.3) 3 5.76 5.25 4.4±0.1 (1.5) 5 5.04 4.59 3.7±0.1 (7.9) 6 5.04 4.65 0.9±0.1 (0.9) Coll α(mrad) r (mm) LT (mm) LF(mm) σ(Ω -1 m -1 ) material 1 324 2 50.62 0 5.88e7 OFE Cu 2 324 1.4 52.40 0 5.88e7 OFE Cu 3 324 1.4 52.40 1000 5.88e7 OFE Cu 6 166 1.4 105.5 0 5.88e7 OFE Cu * PAC07 S. Molloy et al.”Measurements of the transverse wakefields due to varying collimator characteristics”