Download presentation
Presentation is loading. Please wait.
1
ELECTRICAL POROUS SILICON MICROARRAY FOR DNA HYBRIDIZATION DETECTION M. Archer*, D. Persaud**, K. D Hirschman**, M. Christophersen* and P. M Fauchet* *Center for Future Health and Departments of Biomedical Engineering and Electrical and Computer Engineering, University of Rochester, Rochester, NY **Departments of Microelectronic Engineering and Materials Science & Engineering, Rochester Institute of Technology, Rochester, NY Acknowledged support by the Infotonics Technology Center (ITC)
2
OUTLINE Motivation Background Sensing Element Device Integration Electrical Characteristics Conclusions
3
MOTIVATION – “Lab-on-a-Chip” Porous Silicon (PSi) is an excellent sensor material Large surface area to volume ratio Electrical properties sensitive to surface charge Effective medium host PSi-based sensors Sensitive to chemical infiltration Label-free detection of DNA hybridization in real time Reduction to micro-scale dimensions Electrically addressable PSi biosensor microarrays Compatible with silicon process technology Potential integration with microelectronics & microfluidics
4
POROUS SILICON Chemical oxidation: H 2 O 2 treatment for 24hrs hydrophylic internal surface electrical isolation of pores Smooth and straight pore walls Large internal surface area (100) p-type ~ 100µm (vertical scale) + - Electrochemical Etching Macroporous layer (1-2µm pores)
5
DNA HYBRIDIZATION A T G C DNA has specific recognition properties Becomes a charged molecule in its bound form Archer and Fauchet. Phys. Stat. Sol. (a), 198, 2003. Induced change can be detected electrically NaCl buffer solution
6
Electrical contact 10 mm PSi membrane SENSOR RESPONSE 0.60 0.70 0.80 0.90 1.00 1.10 0102030405060708090100110 Normalized Capacitance (a.u) 0 10 20 30 40 50 60 70 80 90 100 Time (min) Probe cDNA 1.1 1 0.9 0.8 0.7 0.6 LCR 100KHz, 90mV p-p G C Equivalent Circuit LabView TM
7
DEVICE INTEGRATION CHALLENGES P-type Silicon PSi sensor membrane Shunt Conductance Sensor Cross-talk Shunt conductance decreases capacitance signal Sensors must have electrical isolation
8
INTEGRATED SENSORS Individual Sensing Element Active sensing region P-type substrate n+ guard ring Sensor “Macroarray”
9
p-type Silicon SiO 2 Si 3 N 4 n + Guard Ring Aluminum LTO PSi KOH Etch Backside Opening Porous sensing membrane n+ guard ring isolation Electrodes PROCESS FLOW
10
SEM X-SECTIONS 100 µ m 10 µ m Angled CleavePSi Membrane
11
0 5 10 15 20 25 30 35 40 45 1.2 1 0.8 0.6 0.4 0.2 0 Normalized Capacitance (a.u) Time (min) ELECTRICAL CHARACTERISTICS CC pDNA ncDNA
12
ELECTRICAL CHARACTERISTICS (continued) 0 5 10 15 20 25 30 35 40 45 1.2 1 0.8 0.6 0.4 0.2 0 pDNA cDNA C ~ 40 % ncDNA Time (min) Discrimination between binding & non-binding DNA Normalized Capacitance (a.u)
13
MICROSCALE INTEGRATION 550µm 4 X 4 Microarray Optical Micrographs
14
CONCLUSIONS PSi-based biosensors exhibit an electrical response to DNA hybridization Sensor arrays have been fabricated A unique electrical isolation scheme has been developed Future work in system integration