Presentation is loading. Please wait.

Presentation is loading. Please wait.

Target Test Report Given permission for a maximum of 5000 actuations. Performed 3679 actuations, 3654 with the gate valve open. Ran target at 0.4 Hz to.

Similar presentations


Presentation on theme: "Target Test Report Given permission for a maximum of 5000 actuations. Performed 3679 actuations, 3654 with the gate valve open. Ran target at 0.4 Hz to."— Presentation transcript:

1 Target Test Report Given permission for a maximum of 5000 actuations. Performed 3679 actuations, 3654 with the gate valve open. Ran target at 0.4 Hz to minimise cooling issues and to maximise time to adjust parameters. Target hold position T = 35 C. Actuate (0.4 Hz) T = 55 C Tested the time delay and depth control mechanisms. Scanned parameter space to find optimum delay time and dip depth. Optimum depth ~45 mm reproducible. Optimum delay 5.9 (ms) from trigger 10 ms before injection Problem with trigger - GMS – from ISIS - solved. Problem with ADC for beam loss signal not solved. Tested target in 128/50 mode and saw that we could extract target in time to miss following ISIS pulse. Happy with performance of target……………

2

3


Download ppt "Target Test Report Given permission for a maximum of 5000 actuations. Performed 3679 actuations, 3654 with the gate valve open. Ran target at 0.4 Hz to."

Similar presentations


Ads by Google