Download presentation
1
Lasers and Optics of Gravitational Wave Detectors
Rick Savage LIGO Hanford Observatory
2
GW detector – laser and optics
end test mass 4 km (2 km) Fabry-Perot arm cavity recycling mirror input test mass beam splitter Power Recycled Michelson Interferometer with Fabry-Perot Arm Cavities signal
3
Closer look - more lasers and optics
4
Pre-Stabilized Laser System
Laser source Frequency pre-stabilization and actuator for further stab. Compensation for Earth tides Power stab. in GW band Power stab. at modulation freq. (~ 25 MHz)
5
Initial LIGO 10-W laser Master Oscillator Power Amplifier configuration (vs. injection-locked oscillator) Lightwave Model 126 non-planar ring oscillator (Innolight) Double-pass, four-stage amplifier Four rods watts of laser diode pump power 10 watts in TEM00 mode
6
LIGO I PSL performance Running continuously since Dec on Hanford 2k interferometer Maximum output power has dropped to ~ 6 watts Replacement of amplifier pump diode bars had restored performance in other units Servo systems maintain lock indefinitely (weeks - months)
7
Frequency stabilization
Three nested control loops 20-cm fixed reference cavity 12-m suspended modecleaner 4-km suspended arm cavity Ultimate goal: Df/f ~ 3 x 10-22
8
Power stabilization 3e-8/rtHz In-band (40 Hz – 7 kHz) RIN
Sensors located before and after suspended modecleaner Current shunt actuator - amp. pump diode current RIN at 25 MHz mod. freq. Passive filtering in 3-mirror triangular ring cavity (PMC) Bandwidth (FWHM) ~ 3.2 MHz 3e-8/rtHz
9
Earth Tide Compensation
Up to 200 mm over 4 km Prediction applied to ref. cav. temp. (open loop) End test mass stack fine actuators relieve uncompensated residual 100mm prediction residual
10
Concept for Advanced LIGO laser
Being developed by GEO/LZH Injection-locked, end-pumped slave lasers 180 W output with 1200 W of pump light
11
Brassboard Performance
LZH/MPI Hannover Integrated front end based on GEO 600 laser – watts High-power slave – 195 watts M2 < 1.15
12
Concept for Advanced LIGO PSL
13
Core Optics – Test Masses
Low-absorption fused silica substrates 25 cm dia. x 10 cm thick, 10 kg Low-loss ion beam coatings Suspended from single loop of music wire (0.3 mm) Rare-earth magnets glued to face and side for orientation actuation Internal mode Qs > 2e6
14
LIGO I core optics Caltech data
RITM ~ 14 km (sagitta ~ 0.6 l) ; RETM ~ 8 km Surface uniformity ~ l/100 over 20 cm. dia. (~ 1 nm rms) “Super-polished” – micro-roughness < 1 Angstrom Scatter (diffuse and aperture diffraction) < 30 ppm Substrate absorption < 4 ppm/cm Coating absorption < 0.5 ppm
15
Adv. LIGO Core Optics fused silica sapphire
LIGO recently chose fused silica over sapphire Familiarity and experience with polishing, coating, suspending, thermally compensating, etc. – less perceived risk Other projects (e.g. LCGT) still pursuing sapphire test masses Thermal noise in coatings expected to be greatest challenge fused silica sapphire 38 cm dia., 15.4 cm thick, 38 kg
16
Processing, Installation and Alignment
Experience indicates that processing and handling may be source of optical loss gluing vacuum baking wet cleaning suspending balancing transporting
17
Thermal Issues Surface absorption depth radius Bulk absorption
Circulating power in arm cavities ~ 25 kW for initial LIGO ~ 600 kW for adv. LIGO Substrate bulk absorption ~ 4 ppm/cm for initial LIGO ~ 0.5 ppm/cm ($) for adv. LIGO Coating absorption ~ 0.5 ppm for initial & adv. LIGO Thermo-optic coefficient dn/dT ~ 8.7 ppm/degK Thermal expansion coefficient 0.55 ppm/degK “Cold” radius of curvature of optics adjusted for expected “hot” state depth radius Bulk absorption
18
Thermal compensation system
CO2 Laser ? ZnSe Viewport ITM PRM SRM ITM Compensation Plates Over-heat Correction Under-heat Correction Inhomogeneous Correction Adv. LIGO concept
19
Coating vs. substrate absorption
Optical path difference Surface distortion substrate coating coating substrate OPD almost same for same amount of power absorbed in coating or substrate Power absorbed in coating causes ~ 3 times more surface distortion than same power absorbed in bulk
20
Summary LIGO utilizes 10-W solid state lasers
Relative frequency stability ~ 10-21/rtHz Relative power stability ~ 10-8/rtHz Advanced LIGO lasers: similar requirements at 200 watt power level LIGO test masses (mirrors) 25 cm dia., 10 cm thick fused silica Surface uniformity ~ l/100 p-v (1 nm rms) over 20 cm diameter Coating absorption < 1 ppm, bulk absorption ~ few ppm/cm Active thermal compensation required to match curvatures of optics Non-invasive measurement techniques required for characterizing performance of optics
21
Anomalous absorption in H1 ifo.
ITMY ITMX Negative values imply annulus heating Significantly more absorption in BS/ITMX than in ITMY How to identify absorption site? TCS power is absorbed in HR coatings of ITMs
22
Need for remote diagnostics
Water absorption in viton spring seats makes vacuum incursions very costly. Even with dry air purge, experience indicates that 1-2 weeks pumping required per 8 hours vented before beam tubes can be exposed to chambers Development of remote diagnostics to determine which optics responsible of excess absorption
23
Spot size measurements
ITMX BeamView CCD cameras in ghost beams from AR coatings Lock ifo. w/o TCS heating Measure spot size changes as ifo. cools from full lock state Curvature change in ITMX path about twice that in ITMY path ITMY
24
Arm cavity g factor changes
Again, lock full ifo. w/o TCS heating, break lock, lock single arm and measure arm cavity g factor at precise intervals after breaking lock g factor change in Xarm larger than Yarm by factor of ~ 1.6 Calibrate with TCS (ITM-only surface absorption)
25
Results and options Beamsplitter not significant absorber
ITMX is a significant absorber ~ 25 mW/watt incident ITMY absorption also high ~ 10 mW/watt incident Factor of ~5 greater than absorption in H2 or L1 ITMs Options Try to clean ITMX in situ Replace ITMX Higher power TCS system 30-watt TCS laser was tested Eventually ITMX was replaced and ITMY was cleaned in-situ ETM surface ITM surface ITM bulk From analysis by K. Kawabe
26
Origin of G-factor measurement technique
Simple question: “For a resonant optical cavity, can the Pound-Drever-Hall locking signal distinguish between frequency and length variations?” i.e. does Of course! Or does it?
27
High-frequency response of optical cavities
Dynamic resonance of light in Fabry-Perot cavities (Rakhmanov, Savage, Reitze, Tanner 2002 Phys. Lett. A, ).
28
High frequency length response
1FSR 2FSR LIGO band Peaks in length response at multiples of FSR suggest searches for GWs at high frequencies. HF response to GWs different than length response Different antenna pattern, but still enhancement in sensitivity
29
High frequency response to GWs
Long wavelength approximation not valid in this regime Antenna pattern becomes a function of source frequency as well as sky location and polarization All-sky-averaged response about a factor of 5 lower than at low freq. Significant sensitivity near multiples of 37.5 kHz (arm cavity FSR) Movie (by H. Elliott): Antenna pattern for one source polarization as source frequency sweeps from 22 to 36 kHz
30
G-factor Measurement Technique
Dynamic resonance of light in Fabry-Perot cavities (Rakhmanov, Savage, Reitze, Tanner 2002 Phys. Lett. A, ). Laser frequency to PDH signal transfer function, Hw(s), has cusps at multiples of FSR and features at freqs. related to the phase modulation sidebands.
31
Misaligned cavity Features appear at frequencies related to higher-order transverse modes. Transverse mode spacing: ftm = f01- f00 = (ffsr/p) acos (g1g2)1/2 g1,2 = 1 - L/R1,2 Infer mirror curvature changes from transverse mode spacing freq. changes. This technique proposed by F. Bondu, Aug Rakhmanov, Debieu, Bondu, Savage, Class. Quantum Grav. 21 (2004) S487-S492.
32
H1 data – Sept. 23, 2003 2ffsr- ftm Lock a single arm
Mis-align input beam (MMT3) in yaw Drive VCO test input (laser freq.) Measure TF to ASPD Qmon or Imon signal Focus on phase of feature near 63 kHz 2ffsr- ftm
33
Data and (lsqcurvefit) fits.
ITMx TCS annulus heating decrease in ROC (increase in curvature) R = m R = m Assume metrology value for RETMx = 7260 m Metrology value for ITMx = m
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.