From CUORICINO to CUORE: To probe the inverted hierarchy region On behalf of the CUORE collaboration DUSL Meeting, Washington DC November 2,-4, 2007 Frank Avignone University of South Carolina and INFN Laboratori Nazionali del Gran Sasso
2
The CUORE collaboration ITALY UNITED STATES
3
Decay modes for Double Beta Decay (A,Z) (A,Z+2) + 2e - neutrinoless Double Beta Decay (0 -DBD) never observed (except KKDK claim) > 10 25 y (A,) (A,Z+2) + 2e - + 2 e 2 Double Beta Decay allowed by the Standard Model observed : = 10 19 -10 21 y
4
Electron sum energy spectra in DBD The shape of the two electron sum energy spectrum enables us to distinguish between the two decay modes sum electron energy / Q two neutrino DBD continuum with maximum at ~1/3 Q neutrinoless DBD peak enlarged only by the detector energy resolution
5
130 Te as a DBD candidate 130 Te as a DBD candidate high natural isotopic abundance (nat. abundance = 33.87 %) high transition energy ( Q = 2530 keV ) encouraging theoretical matrix element observed with geo-chemical techniques ( incl = ( 7 - 27 ) 10 20 y) 2 DBD decay observed by a precursor bolometric experiment (MIBETA) and by NEMO-3 at the level = (7.6 ) 10 20 y Large natural abundance Low-cost Expandability of Double- Beta Decay experiments
6
The bolometric technique for 130 Te: detector concepts
7
Tellurium oxide bolometers for DBD Energy absorber single TeO 2 crystal 790 g 5 x 5 x 5 cm Thermometer (Neutron transition doped Ge chip)
8
CUORICINO/CUORE Location CUORICINO experiment installed in Laboratori Nazionali del Gran Sasso L'Aquila – ITALY the mountain provides a 3500 m.w.e. shield against cosmic rays R&D final tests for CUORE (hall C) CUORE (hall A) CUORICINO (hall A)
9
CUORICINO = tower of 13 modules, 11 modules x 4 detector (790 g) each 2 modules x 9 detector (340 g) each M = ~ 41 kg ~ 5 x 10 25 130 Te nuclei The CUORICINO structure Cold finger Tower Lead shield Same cryostat and similar structure as previous pilot experiment Coldest point
10
Detector performance Detector performance 2.61.60.6 Energy [MeV] Counts (/1.2 keV) 10 60 238 U + 232 Th calibration spectrum 208 Tl 214 Bi 40 K 228 Ac Performance of CUORICINO detectors (5 5 5 cm 3 - 790 g): Detector base temperature: ~ 7 mK Detector operation temperature: ~ 9 mK Detector response: ~ 250 V/ MeV FWHM resolution: ~ 3.9 keV @ 2.6 MeV
11
130 Te 0 60 Co sum peak 2505 keV ~ 3 FWHM from DBD Q-value /2 0 (y) > 3.0 10 24 y (90% CL ) M < 0.38 – 0.58 eV CUORICINO results MT = 11.83 kg 130 Te y Bkg = 0.18±0.02 c/keV/kg/y Rodin et al. nucl-th/0706.4304 Caurier et al., New Shell Model Average FWHM resolution for 790 g detectors: 7 keV
12
CUORE = close-packed array of 988 detectors 19 towers - 13 modules/tower - 4 detectors/module M = 741 kg ~ 10 27 130 Te nuclei Compact structure, ideal for active shielding From CUORICINO to CUORE ( Cryogenic Underground Observatory for Rare Events ) Each tower is a CUORICINO-like detector Special dilution refrigerator and granularity
13
CUORE funding and schedule CUORE has a dedicated site in LNGS and construction of the site has started The CUORE refrigerator has been funded and is on order 1000 crystals: Funding by INFN (500 already ordered) and 500 to be purchased by LLNL with US DOE funding The CUORE Electronics: Funded in Sept. 07 by the NSF via The University of South Carolina First CUORE tower “CUORE-0" assembled in 2008 and operated in 2009 in CUORICINO Cryostat CUORE scheduled to begin in January 2011
14
CUORE sensitivity Montecarlo simulations of the background show that b ~ 0.001 counts / (keV kg y) is possible with the present bulk contamination of the bolometers The problem is surface background (energy-degraded alpha, beta ) must be reduced by more than a factor of 10 below that of CUORICINO: work in progress! 10 y sensitivity (1 ) with conservative Assumption: b = 0.01 counts/(keV kg y) FWHM = 10 keV 10 y sensitivity (1 ) with aggressive assumption: b = 0.001 counts/(keV kg y) FWHM = 5 keV M < 38-58 meV QRPA-SM M < 23-33 meV QRPA-SM
15
CUORE and the inverted hierarchy region Quasi-degenarate S. Pascoli, S.T. Petcov Inverted hierarchy Normal hierarchy ~20 meV ~50 meV Inverted hierarchy band M Lightest neutrino mass
16
The CUORE background model Sources of the background 1.Radioactive contamination in the detector materials (bulk and surface) 2.Radioactive contamination in the set-up, shielding included 3.Neutrons from rock radioactivity 4.Muon-induced neutrons Monte Carlo simulation of the CUORE background based on: 1.CUORE baseline structure and geometry 2.Gamma and alpha counting with HPGe and Si-barrier detectors 3.CUORICINO experience CUORICINO background model 4.Specific measurements with dedicated bolometers in test DR in LNGS Results…..
17
The CUORE background components Component Background in DBD region ( 10 -3 counts/keV kg y ) Environmental gamma Apparatus gamma Crystal bulk Crystal surfaces Close-to-det. material bulk Close-to-det. material surface Neutrons Muons < 1 < 0.1 < 3 < 1 ~ 20 – 40 ~ 0.01 The only limiting factor
18
(A) Passive methods surface cleaning (B) Active methods ( “reserve weapons” and diagnostic ) events ID Mechanical action Chemical etching / electrolitic processes Surface passivation Strategies to control surface background surface sensitive bolometers scintillating bolometers able to separate from electrons
19
Can CUORICINO challange the KKDK claim of evidence? T 1/2 0v (y) = (0.91-3.6) 10 25 (3σ range) m ββ = 0.23 – 0.51 eV (3σ range) Klapdor-Kleingrothaus et al. Modern Physics Letters A21(2006) 1547. Best value: 2.23x10 25 y Nuclear matrix element of Rodin et al., Erratum nucl-th/0706.4304 CUORICINO and the KKDK claim of evidence Evidence of decay of 76 Ge claimed by a subset of the Heidelberg- Moscow collaboration (Klapdor-Kleingrothaus et al.)
20
T 1/2 0v (Klapdor et al.) T 1/2 0v ( 130 Te)Choose a nuclear model Compare experiments with different isotopes QRPA Tuebingen-Bratislava -Caltech group: erratum: nucl-th/0706.4304 Civitarese and Suhonen: Nucl. Phys. A 761(2005) 313. Shell Model: E. Caurier et al., nucl-th:0709.0277 Use three recent nuclear structure models:
21
KKDK DISCOVERY RANGE: CUOICINO 90%LOWER BOUND CUORICINO SENSITIVITY DISCOVERY RANGE IS Te-130 EQUIVELENT Ranges:
22
Conclusions Bolometers represent a well established technique, very competitive for neutrinoless DBD search CUORICINO and NEMO-3 are presently the most sensitive 0 DBD running experiments, with chance to confirm the HM claim of evidence if this is correct CUORICINO demonstrates the feasibility of a large scale bolometric detector (CUORE) with good energy resolution and background CUORE is a next generation detector; it is funded and is scheduled to begin operation in January 2011 Recent results on background suppression confirm the capability to explore the inverted hierarchy mass region with CUORE