Kitchen Ventilation
2
Systems
3
Multi Point Ventilation
4
Heat Recovery Ventilator
5
Bath Ventilation
6
Bathroom Exhaust Fans
7
Bathroom Exhaust Fans CODE for Baths without bathing or spas:
3 SF Glazing ½ Operable or Baths 75SF or less - 50 CFM Fan or Over 75 SF – Intermittent Ventilation System 1 air change every 12 minutes Continuous Ventilation System at 20 CFM
8
Bathroom Exhaust Fans Baths with bathing and spas 50 CFM Intermittent
or 20 CFM Continuous
9
Multi Point Ventilation
10
Kitchen Ventilation Considerations
Fan Type Propeller Fan – Limited air capacity and noisy Axial Fan – Better air movement but still noisy Centrifugal Blower (Squirrel Cage) The best
11
Axial Fan
12
Centrifugal Blower
13
Sound Levels Sound is measured in Sones
1-Sone equals the loudness of a pure tone having a frequency of 1,000 hertz at 40 decibels.
14
Decibels 0 The softest sound a person can hear with normal hearing
10 normal breathing 20 whispering at 5 feet 30 soft whisper 50 rainfall 60 normal conversation 110 shouting in ear 120 thunder
15
Sones The Home Ventilation Institute sets a limit of 9.0 sones for kitchen fans up to 500 CFM Reference – A fan with a sone rating of 8.0 sones is twice as loud as one rated at 4.0 sones. Reference - Refrigerators run at about 1.0 sone.
17
Broan Silent Series 110 cfm .7 Sones
18
In-Line Ventilator Fan 110 CFM 1.0 Sones 210 CFM 2.0 Sones
19
Kitchen Ventilation
20
Kitchen Exhaust Fans CODE 100 CFM Intermittent Or 25 CFM Continuous
21
Multi Point Ventilation
22
Vented Hood System
23
Recirculating Fan in Microwave Combo
24
Kitchen Ventilation Heat Grease Steam Odor Smoke
25
Recirculating Range Hood
26
Recirculating Ventilation System
This type of system will only remove two Heat Steam
27
Downdraft
28
Down Draft Ventilation
29
Down Draft Ventilation
30
Range Hood Installation
40
Integral Fan Vented Through Roof
41
In Line Fan
42
Integral Through Soffit
43
Remote Ventilator
44
Through Crawlspace
45
Down Draft Through Floor
46
Down Draft Through Roof
47
Kitchen Ventilation Considerations
Fan – 250 CFM minimum Ducts Duct run lengths Interior Fan (power) Keep duct runs as short and straight as possible. 6” round or 3 ¼” x 10 rectangular ducts Maximum run = 25’ maximum
48
Kitchen Ventilation Considerations
Exterior or In-Line Fan (power) 9” round or 3 ¼” x 14” rectangular duct Maximum run = 55’ maximum