Presentation is loading. Please wait.

Presentation is loading. Please wait.

Thermal Protection System Testing in High Enthalpy Facility Richard French Vitaliy Grigoryev November 10, 2005 Team HEaTT Progress Report #3.

Similar presentations


Presentation on theme: "Thermal Protection System Testing in High Enthalpy Facility Richard French Vitaliy Grigoryev November 10, 2005 Team HEaTT Progress Report #3."— Presentation transcript:

1 Thermal Protection System Testing in High Enthalpy Facility Richard French Vitaliy Grigoryev November 10, 2005 Team HEaTT Progress Report #3

2 Summary Schedule Update Facility update Testing Update

3 Schedule

4 Facility Overview A – Diffuser; B – Test Section; C – Heat Source; D – Specimen Mounting; E – Test Specimen; F – Ventilation Fan; G – Data Acquisition System

5 High Enthalpy Testing Facility Smoldering Tunnel SetupPropane Tank Placement Torch + Sample mounting Data Acquisition System

6 Thermocouples Sensor Data Processing/Presentation Data storage 3 Iron-constantan (J)- thermocouples Doric Trendicator and Multipoint selector (analog) Pen and paper

7 Test Results

8 Distance : (Sample to Torch) Peak Sample Temp 52.5 cm116 C 33 cm561 C

9 Problems Flame blowout convective cooling of sample heat rising to top of tunnel thermocouple insulation damage Damage to thermocouple wire insulation

10 Thanks QUESTIONS?


Download ppt "Thermal Protection System Testing in High Enthalpy Facility Richard French Vitaliy Grigoryev November 10, 2005 Team HEaTT Progress Report #3."

Similar presentations


Ads by Google