Download presentation
Presentation is loading. Please wait.
1
Metabolic Heat Generation During Exercise ME 340 Final Project Ryan Huff & Scott Wood
2
Experimental Setup Goal: To determine the efficacy of dry release exercise shirts Procedure: –Used 24 AFROTC Cadet Volunteers –Measured body temperature from the armpit using a thermocouple before and after exercise –Performed a 2 3 factorial experiment –Three Factors: Exercise Length (5/10 min) Exercise Type (Run/Walk) Shirt Type (DryRel/Cotton)
3
Analytical Model Energy Balance: Assumptions –Model body as long cylinder –Conduction through the muscles to the skin –Convection and radiation from the skin to the environment –(ε = 1) Heat Source Shirt Control Surface Air, T ∞ TsTs TbTb
4
Experimental Results Interaction P-values Shirt Type*Ex Type 0.10 Shirt Type*Ex Length0.01 Ex Type*Ex Length0.08 Shirt Type*Ex Type*Ex Length 0.04 Shirt Type Ex Type Ex Length Shirt Type DryRelease Cotton
5
Conclusions Dry Release Shirt had an effect on body temperature during exercise Using a Dry Release shirt will better maintain core body temperature during activity Model only works for data collected and range specified Further study and modeling need to be performed
6
Recommendations Length of exercise –20 and 50 minutes –Should use heart rate monitors to ensure more uniform exercise intensity Measurement Accuracy –Use thermocouples with faster response –Measure body temperature from a different location…uh oh, where?
7
Dry Release (h)
8
Cotton (h)
Similar presentations
© 2024 SlidePlayer.com. Inc.