Governing equation for concentration as a function of x and t for a pulse input for an “open” reactor.
2
D d or Pe is usually unknown so we need to determine these parameters by injecting a conservative substance and measure its concentration as a function of time and/or distance in the reactor. Two choices: -synoptic sampling at some time sample at different x values. -single point sampling (fixed x) at different t values
3
For synoptic sampling we get a symmetrical Guassian distribution for concentration no matter what D d or Pe exists in the reactor. This is shown in the following slide.
4
Pe = 333 Pe = 111 Pe = 56 Synoptic sampling
5
A Gaussian distribution has the form:
6
If we take and normalize it by multiplying it by A/M and let We get:
7
This is exactly the Gaussian distribution function so all we have to do is calculate the standard deviation to calculate D d as long as the concentration versus x is symmetrical – which it will be if the sampling is synoptic and the system is “open” The system can be considered “open “ if the concentration curve exhibits very low numbers at low and high x values. This is because the sampling is taking place at in a region of the reactor far from the boundaries of the reactor or, in fact, the boundary conditions are truly “open” in the sense that they exhibit the same D d as the reactor.
8
Now if the reactor is being sampled at a single point at multiple times the response curve ( C versus t) may be symmetrical if D d is low enough. In this case we can still use computation of the standard deviation. In this case we use:
9
As D d increases the response curve become skewed and therefore non-Gaussian and we need another method to determine D d. The following plot shows how the skewness develops with increasing D d (decreasing Pe).
10
t peak Pe = 67 Pe = 6.7 Pe = 3.3 time
11
Note that there is an increase in skewness so the Gaussian distribution is no longer appropriate. However, computation of and are as before: But now you can’t use
12
Beside the increase in skewness also notice there is a shift in the position (x value) of the peak concentration, t peak as a function of Pe (D d ). It is possible to find the relationship between Pe or D d and this shift in t peak. by differentiating C(t) and setting it equal to zero to solve for x at the peak C. This can be done for a variety of Pe values to find:
13
This equation plots as: t peak / Finding t peak can done graphically by plotting C(t). t peak occurs at the max C.
14
Given the possible skewness of the C vs. t profile for single point sampling, the mean predicted retention time,, will, in general, be greater than the time at which the peak concentration passes the monitoring point, = V/Q (i.e., reactor volume divided by flow rate, or reactor length divided by advective velocity).
15
If D d (or Pe) is known is predicted by :
16
Integration of this expression is difficult but a numerical technique can be used to show the effect of Pe on the ratio of to .
17
This graph can be used determine Pe after computing and dividing by the theoretical retention time
18
Finally, Pe can be determined for single point sampling at high dispersion using statistical methods even if the Gaussian conditions (symmetry) don’t exist. The standard deviation and t bar calculations still apply:
19
After some rather difficult math using Gamma functions it can be shown that for an open system: And for a closed system using numerical methods: