CMS Tracker Week – Module Test Meeting – July 2003 – Patrick Gartung 1 Long term rod testing software Patrick Gartung University of California, Riverside.

Similar presentations


Presentation on theme: "CMS Tracker Week – Module Test Meeting – July 2003 – Patrick Gartung 1 Long term rod testing software Patrick Gartung University of California, Riverside."— Presentation transcript:

1 CMS Tracker Week – Module Test Meeting – July 2003 – Patrick Gartung 1 Long term rod testing software Patrick Gartung University of California, Riverside

2 CMS Tracker Week – Module Test Meeting – July 2003 – Patrick Gartung 2 Current Software Status Installing CERN Redhat v7.2 and Daq_CMS_Like software on rod assembly test stand computer 2 graduate students assisting Control of CAEN SY127 HV crate with A1303 Integrated with Daq_CMS_Like software http://hep.ucsb.edu/people/gartung/A1303_mod/a1303.htm Temperature control of Rochester “freezer” and software interlocks being developed using Labview See Ricardo Eusebi’s talk

3 CMS Tracker Week – Module Test Meeting – July 2003 – Patrick Gartung 3 Current Software Use XROD for readout during rod assembly No multiplexer support To readout 1 SS4 rod (12 UTRI connections) need 2 FED (16 UTRI connections) To readout 1 DS4 rod (24 UTRI connections) need 3 FED (24 UTRI connections) Use Long Term Test for Rods Interface with Rochester “freezer” controls via TCP/IP Currently works with 1 FED and 1 FEC Only tested with 1 CCU -> 6 modules Cable length could be an issue with 2+ CCU on one FEC Limited to 80 UTRI connections with 1 FED+multiplexer 4x10 = 40 pairs or 2x10 = 20 triplets Readout 6 SS4 rods (6 rods x 6 mods x 1 pair = 36 pairs) Readout 3 DS4 rods (3 rods x 12 mods x 1 pair = 36 pairs) Readout 3 SS6 rods (3 rods x 6 mods x 1 triplet = 18 triplets)

4 CMS Tracker Week – Module Test Meeting – July 2003 – Patrick Gartung 4 Software Considerations Extend Long Term Test to multiple rods Add support for N FED with N multiplexers Gives Nx80 UTRI connections Extend XROD to multiple rods Add multiplexer support to readout multiple rods(?) Or add support for 4+ FED(?) Need separate temp and voltage control programs No unattended readout Use XDAQ? No experience using it

5 CMS Tracker Week – Module Test Meeting – July 2003 – Patrick Gartung 5 Conclusions Current software can support initial rate of rod assembly testing and long term testing Need to extend software to support full rate of rod long term testing