Download presentation
Presentation is loading. Please wait.
1
Solenoids The authors would like to thank the following people for their dedication, generosity, and support which greatly contributed to the success of this project. Chris Roush – Marshall Music Co. Greg Ritchey – Magnet-Schultz of America Rich Yarch – MSU Upholstery Shop Dr. Robert Hubbard Mr. Timothy Hinds – Project Advisor Reverend Richard Moe was born with spinal muscular atrophy (SMA), a progressive & degenerative muscle condition. With the recent loss of the strength in his fingers, he was unable to effectively operate the valves on his tuba. The scope of this project was to develop an assistive valve actuation system that would allow Mr. Moe to continue to play his instrument with minimal strength. Additionally, a support system was necessary; this would bear the weight of the tuba while also raising the height of the mouthpiece to promote beneficial posture. Valve Actuation System: -Actuators Linear solenoids provided the force and displacement to operate the instrument valves. Assistive Actuation of Brass Instrument Valves Raymond Gallagher, Daniel Isaac, Zachary Kaltz, Matthew Ryerkerk Instrument Support System: A contoured cushion was chosen as the support system. Rubber grip fabric on the bottom prevents the instrument from sliding off the seat. The straps attach the cushion to the tuba and can compress the cushion for an adjustable height. Valve Actuation System: It was required that the solenoids have a holding force of at least 1.2 lbs (5.3 N), a maximum response time of 0.3 seconds, and a stroke distance of 1inch (2.54 cm). Further, a 100% duty cycle was required. The final design was determined to have a response time of approximately 0.2 seconds for each of the valves. It was calculated that a.625 Amp current at 24 Volts was needed to operate the device. Spacing of the solenoids was an important factor in the modeling of the device. The valves on the tuba were 0.5 inches apart. Instrument Support System: The instrument support pad was modeled to fit in between the legs of Mr. Moe and rest on the seat of the wheelchair. A cutout in the center of the pad was made in and straps were added to ensure secure attachment to the tuba. 2.56 inches 0.75 inches 1 inch 1 2 3 Figure 1. Linear solenoids (R24X30 Magnet-Schultz) Figure 5 (a). Valve spacing as seen on actual instrument Figure 5 (b). Valve in open and closed positions with a 1 inch stroke distance Valves Springs Valves Additional work optimizing the size and weight of the device is needed in order obtain the most robust product. Additionally, the performance of the device can be optimized by developing a custom made solenoid design specifically for the required force and stroke distance required. The valve actuation system developed should not be restricted use only with the tuba. Additional work is necessary in order to modify the device so as to make it compatible with an instrument being played. Pushing force = 1.2 lbs Restoring force of spring Valve Open Valve Closed Acrylic Bolts Figure 3. The mounted actuation system has an adjustable control box. Acknowledgements III - Modeling I - Introduction II - Design IV – Future Considerations Figure 4. The solenoids (D=1.5 inches) were modeled in Unigraphics as per the dimensions specified by the manufacturer Valves Figure 2. Three solenoids were mounted to acrylic plates. -Control Box Low-resistance switches independently controlled the solenoids. Velcro on the control box and mounting allowed adjustable positioning for user comfort. -Mounting Acrylic plates with foam are bolted to each other to hold the solenoids above the valves. Figure 4. The support cushion attaches to the bottom of the tuba.
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.