Presentation is loading. Please wait.

Presentation is loading. Please wait.

Cooling Only 38MFC/ 40MFC Heat Pump 38MFQ/ 40MFQ

Similar presentations


Presentation on theme: "Cooling Only 38MFC/ 40MFC Heat Pump 38MFQ/ 40MFQ"— Presentation transcript:

1 Cooling Only 38MFC/ 40MFC Heat Pump 38MFQ/ 40MFQ
PROPRIETARY and CONFIDENTIAL

2 PRODUCT OVERVIEW High Wall Cooling Only 38MFC/ 40MFC
Heat Pump 38MFQ/ 40MFQ 15 SEER Line lengths up to 65’ Inverter Driven Compressor Rotary compressor 3 indoor unit fan speeds Turbo mode Motorized louver allows fixed or oscillating motion Indoor sound: as low as 34 decibels Cleanable filters CONTROL STANDARD FEATURES Wireless remote control standard Turbo button Optional wired remote Control Wired remote controller Wireless remote controller UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution

3 MF SERIES HIGH-WALL FEATURES
Comfort: Quiet operation Auto changeover on heat pumps Auto Swing Air direction Cold blow prevention on Heat Pump Turbo fan mode Wireless remote Manual mode for emergency operation Auto restart Dry mode UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution

4 MF SERIES HIGH-WALL FEATURES
Installation Flexibility/Ease Of Service: Mounting brackets for indoor unit Long lines application Max outdoor ambient of 115°F in cooling Operates down to 14°F Condensate pump accessory Test mode On board and on unit diagnostic LED lights Reliability 3 minute time delay Over current protection on compressor Indoor coil freeze protection Condenser high temperature protection on HP & AC Indoor evaporator high temperature protection on HP UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution

5 SPECs Cooling Only (MFC Series)
System Size 9 12 18 22 Outdoor Model 38MFC 38MFC 38MFC 38MFC 38MFC Indoor Model 40MFC 40MFC 40MFC 40MFC 40MFC Performance Cooling Rated Capacity Btu/h 9,000 12,000 18,000 22,000 Cooling Cap. Range Min - Max Btu/h 4,000-10,000 4,500-13,000 5,500-19,000 6,500-24,000 SEER 15 EER 10 8.5 Controls Wireless (°C, °F, Convertible) Standard - Convertible Wired (°C, °F, Convertible) Optional: KSACN0101CAC Operating Range Cooling Outdoor DB Min - Max °F Cooling Indoor DB Min -Max °F 63-90 Piping Total Piping Length ft. 65 98 Piping Lift ft. * 25 30 Pipe Connection Size - Liquid (In) 1/4 3/8 Pipe Connection Size - Suction (In) 1/2 5/8 Electrical Voltage Power Supply Indoor unit powered from outdoor unit Outdoor - MCA 19 14 16 Outdoor - Fuse Rating (MOCP) 20 Outdoor Dimensions (W X H X D) In (net) 30.7 x 21.2 x 9.8 29.9 x 23.2 x 11.2 33.3 x 27.6 x 12.6 Net Weight (lbs.) 58.4 61.7 76.0 98.1 Sound Pressure dBa 57 58 60 61 Indoor 26.8 x 10.0 x 7.0 30.3 x 10.0 x 7.4 35.6 x 10.8 x 7.8 40.6 x 12.4 x 8.6 15.4 16.5 19.8 26.4 Number of Fan Speeds 4 Airflow (lowest to highest) CFM 131/160/192/215 158/194/230/240 157/193/232/240 236/294/348/395 368/458/547/580 Sound Pressure dBa ( L / M / H) 43/39/34 44/40/36 45/41/37 50/46/42 UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution

6 SPECs Heat Pump (MFQ Series)
System Size 9 12 17 22 Outdoor Model 38MFQ 38MFQ 38MFQ 38MFQ 38MFQ Indoor Model 40MFQ 40MFQ 40MFQ 40MFQ 40MFQ Performance Cooling Rated Capacity Btu/h 9,000 12,000 17,000 22,000 Cooling Cap. Range Min - Max Btu/h 4,000-10,000 4,500-13,000 5,500-19,000 6,500-24,000 SEER 15 EER 10.5 9.5 Heating Rated Capacity Btu/h 18,000 Heating Cap. Range Min - Max Btu/h 4,000-10,500 5,500-19,500 6,500-24,500 HSPF 8.2 Controls Wireless (°C, °F, Convertible) Standard - Convertible Wired (°C, °F, Convertible) Optional: KSACN0101CAC Operating Range Cooling Outdoor DB Min - Max °F 14-115 Heating Outdoor DB Min - Max °F 5 - 75 Cooling Indoor DB Min -Max °F 63-90 Heating Indoor DB Min -Max °F 32-86 Piping Total Piping Length ft. 65 98 Piping Lift ft. * 25 30 Pipe Connection Size - Liquid (In) 1/4 3/8 Pipe Connection Size - Suction (In) 1/2 5/8 Electrical Voltage Power Supply Indoor unit powered from outdoor unit Outdoor - MCA 19 10 14 16 Outdoor - Fuse Rating (MOCP) 20 Outdoor Dimensions (W X H X D) In (net) 30.7 x 21.2 x 9.8 29.9 x 23.2 x 11.2 33.3 x 27.6 x 12.6 Net Weight (lbs.) 70.5 82.7 103.6 Sound Pressure dBa ( Clg / Htg ) 57 58 60 61 Indoor 26.8 x 10.0 x 7.0 30.3 x 10.0 x 7.4 35.6 x 10.8 x 7.8 40.6 x 12.4 x 8.6 15.4 16.5 19.8 26.4 Number of Fan Speeds 4 Airflow (lowest to highest) CFM 131/160/192/215 158/194/230/240 157/193/232/240 236/294/348/395 368/458/547/580 Sound Pressure dBa (L / M / H) Clg 43/39/34 44/40/36 45/41/37 50/46/42 Sound Pressure dBa (L / M / H) Htg 40/35/30 43/38/33 42/36/31 42/38/33 46/42/38 UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution

7 Wireless remote controller Wired remote controller (Optional)
Remote Controllers Temp Up MODE FAN speed TIMER ON TIMER OFF Swing Sweep SLEEP Temp down Turbo LED / F.P Wireless remote controller Wired remote controller (Optional) UTC Building Industrial Systems Confidential and Proprietary Information - Not For Further Distribution