1 OSHA Federal Standards October 1, 2013 – September 30, 2014

2 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. M OST F REQUENTLY C ITED S ERIOUS V IOLATIONS IN C ONSTRUCTION 2014 2 1926 Overall MFC F ALL P ROTECTION – R ESIDENTIAL C ONSTRUCTION P ORTABLE L ADDERS N OT E XTENDED 3 FEET A BOVE L ANDING F ALL P ROTECTION – U NPROTECTED S IDES & E DGES F ALL P ROTECTION – T RAINING E YE AND F ACE P ROTECTION H EAD P ROTECTION S CAFFOLDS – F ALL P ROTECTION A ERIAL LIFTS – F ALL P ROTECTION S AFE A CCESS F ALL P ROTECTION – R OOFING W ORK ON L OW - SLOPED R OOFS M X M M E E L L L M 29 CFR 1926 S UBPARTS

3 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. G ENERAL S AFETY & H EALTH [1926.20 – 35] 3 E MPLOYEE T RAINING P ROGRAMS P ERSONAL P ROTECTIVE E QUIPMENT – E MPLOYER R ESPONSIBILITY I NITIATE AND M AINTAIN A CCIDENT P REVENTION P ROGRAMS I NSPECTIONS BY A C OMPETENT P ERSON SUBPART C H OUSEKEEPING

4 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. O CCUPATIONAL H EALTH & E NVIRONMENTAL C ONTROLS [1926.50 – 66] 4 W ASHING F ACILITIES FOR H ARMFUL C ONTAMINANTS Lead – Employer Personal Full-shift Sampling E MERGENCY E YEWASH /S HOWER Lead – Change Areas Provided Prior to Exposure Assessment L EAD – P ROTECTIVE C LOTHING & E QUIPMENT P ROVIDED P RIOR TO E XPOSURE A SSESSMENT SUBPART D

5 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. P ERSONAL P ROTECTIVE & L IFE S AVING E QUIPMENT [1926.95 – 107] 5 E YE AND F ACE P ROTECTION H EAD P ROTECTION PPE – P ROVIDED U SED & M AINTAINED SUBPART E P AYMENT FOR P ROTECTIVE E QUIPMENT R EQUIRED E YE & F ACE P ROTECTION – ANSI R EQUIREMENTS

6 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. 2A F IRE E XTINGUISHER P ROVIDED PER 3000 SQ FT OF B UILDING A REA E XTINGUISHERS WITH 50 FT OF 5 GALLONS OF FLAMMABLE LIQUIDS P ROTECTING LP G AS S YSTEMS P ROTECTED FROM V EHICULAR D AMAGE F IRE P ROTECTION & P REVENTION [1926.150 – 159] 6 SUBPART F P ORTABLE F IRE E XTINGUISHERS I NSPECTED P ERIODICALLY & M AINTAINED I NSPECTION & M AINTENANCE OF F IRE F IGHTING E QUIPMENT

7 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. S IGNS, S IGNALS & B ARRICADES [1926.200 – 203] 7 T RAFFIC S IGNS AT P OINTS OF H AZARD T RAFFIC C ONTROL S IGNS /D EVICES F LAGGERS - S IGNALING SUBPART G B ARRICADES C ONFORMING TO P ART VI OF THE MUTCD V ISIBILITY OF S IGNS AND S YMBOLS

8 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. M ATERIALS S TORED TO P REVENT S LIDING F ALLING, OR C OLLAPSE M ATERIALS H ANDLING, S TORAGE, U SE & D ISPOSAL [1926.250 – 252] 8 G ENERAL R IGGING E QUIPMENT I DENTIFICATION E XTERIOR D ROP C HUTES R IGGING E QUIPMENT I NSPECTION & R EMOVAL FROM S ERVICE W ELDED A LLOY S TEEL C HAIN S LING I DENTIFICATION SUBPART H

9 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. T OOLS : H AND & P OWER [1926.300 – 307] 9 G UARDING OF R OTATING /M OVING P ARTS G UARDING OF C IRCULAR H AND - HELD R IPSAWS T OOLS D ESIGNED FOR G UARDS – G UARDS IN P LACE G UARDING OF P ORTABLE C IRCULAR S AWS W OODWORKING T OOLS – ANSI R EQUIREMENTS SUBPART I

10 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. W ELDING & C UTTING [1926.350 -354] 10 S ECURING OF C YLINDERS W HILE IN U SE F IRE E XTINGUISHING E QUIPMENT I MMEDIATELY A VAILABLE C YLINDERS S ECURED U PRIGHT O XYGEN AND F UEL -G AS C YLINDER S TORAGE U SING C ABLES N EEDING R EPAIR SUBPART J

11 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. E LECTRICAL [1926.400 – 449] 11 E QUIPMENT I NSTALLATION AND U SE G ROUND F AULT P ROTECTION G ROUNDING P ATH W ORN /F RAYED C ORDS AND C ABLES F LEXIBLE C ORD S TRAIN R ELIEF SUBPART K

12 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. S CAFFOLDS [1926.450 – 454] 12 F ULL P LANKING T RAINING FOR S CAFFOLD U SERS F ALL P ROTECTION A ERIAL L IFTS – F ALL P ROTECTION S AFE A CCESS SUBPART L

13 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. F ALL P ROTECTION [1926.500 – 503] 13 R OOFING W ORK ON L OW - SLOPED R OOFS R OOFING W ORK ON S TEEP R OOFS R ESIDENTIAL C ONSTRUCTION U NPROTECTED S IDES & E DGES F ALL H AZARD T RAINING SUBPART M

14 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. H ELICOPTERS, H OISTS, E LEVATORS, AND C ONVEYORS [1926.550 – 556] 14 H OISTS & E LEVATORS – C OMPLYING WITH M ANUFACTURER ’ S R ECOMMENDATIONS M ATERIAL H OISTS – R IDING P ROHIBITED E XCEPT D URING I NSPECTION & M AINTENANCE O VERHEAD H OISTS – S AFE W ORKING L OAD P OSTED AND N OT TO BE E XCEEDED SUBPART N

15 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. M OTOR V EHICLES, M ECHANIZED E QUIPMENT, & M ARINE O PERATIONS [1926.600 – 606] 15 I NDUSTRIAL T RUCK O PERATOR T RAINING I NDUSTRIAL T RUCKS ANSI B56.1-1969 R EQUIREMENTS M ODIFICATIONS THAT A FFECT C APACITY R ATING S AFE R IDING S PACE ON I NDUSTRIAL T RUCKS S AFETY P LATFORM S ECURED TO C ARRIAGE OR F ORKS SUBPART O

16 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. E XCAVATIONS [1926.650 – 652] C OMPETENT P ERSON - I NSPECTION AND E MPLOYEE R EMOVAL C OMPETENT P ERSON - I NSPECTIONS P ROTECTION FROM F ALLING /R OLLING M ATERIALS AND E QUIPMENT S AFE E GRESS C AVE - IN P ROTECTION SUBPART P 16

17 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. C ONCRETE & M ASONRY C ONSTRUCTION [1926.700 – 706] 17 R EINFORCING S TEEL G UARDING F ORMWORK C APABLE OF S UPPORTING A NTICIPATED L OADS L OCKOUT /T AGOUT OF B ULK C EMENT S TORAGE F ACILITIES B RACING OF P RECAST M EMBERS UNTIL P ERMANENTLY C ONNECTED S EMICIRCULAR M ASONRY S AW G UARDING SUBPART Q

18 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. S TEEL E RECTION [1926.750 – 761] 18 U NSECURED D ECKING IN CDZ E XCEEDING 3,000 SQFT. S TRUCTURAL S TABILITY D URING E RECTION P ROCESSES P ROTECTION FROM F ALL H AZARDS F ALL H AZARD T RAINING F ALL P ROTECTION FOR C ONNECTION SUBPART R

19 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. D EMOLITION [1926.850 – 860] 19 R EMOVAL OF S TRUCTURAL OR L OAD - SUPPORTING M EMBERS S HORING AND B RACING OF W ALLS AND F LOORS E NGINEERING S URVEY P RIOR TO D EMOLITION O PERATIONS C HUTE O PENING P ROTECTED BY A G UARDRAIL N OT D ROPPING M ATERIALS O UTSIDE E XTERIOR W ALLS SUBPART T

20 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. B LASTING AND THE U SE OF E XPLOSIVES [1926.900 – 914] 20 I NSPECTION OF B LASTED A REAS 910(b) SUBPART U

21 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. P OWER T RANSMISSION AND D ISTRIBUTION [1926.950 – 968] 21 H OST E MPLOYER I NFORMING C ONTRACTOR OF I NSTALLATION S AFETY C HARACTERISTICS 950(c)(1) SUBPART V

22 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. 22 R EMOUNTING OF ROPS WITH E QUAL Q UALITY OF O RIGINAL M OUNTING ROPS ON E QUIPMENT M ANUFACTURED ON OR A FTER S EPT 1, 1972 SUBPART W R OLLOVER P ROTECTIVE S TRUCTURE ; O VERHEAD P ROTECTION [1926.1000 – 1003]

23 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. S TAIRWAYS AND L ADDERS [1926.1050 – 1060] 23 U SING T OP S TEP AS A S TEP U SE OF D EFECTIVE P ORTABLE L ADDERS P ORTABLE L ADDER – 3 FEET A BOVE L ANDING S URFACE A PPROPRIATE U SE L ADDER & S TAIRWAY H AZARD T RAINING SUBPART X

24 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. T OXIC & H AZARDOUS S UBSTANCES [1926.1100 – 1152] 24 A SBESTOS – E XPOSURE M ONITORING C LASS I, II, AND III W ORK IN R EGULATED A REA A SBESTOS – E XPOSURE A SSESSMENT BY A C OMPETENT P ERSON A SBESTOS – B UILDING O WNER D ETERMINATION P RIOR TO W ORK A SBESTOS – T RAINING P ROGRAM SUBPART Z

25 N UMBER OF S ERIOUS V IOLATIONS – FY 2014 29 CFR 1926. C RANES AND D ERRICKS IN C ONSTRUCTION [1926.1400 – 1442] 25 I NSPECTION D OCUMENTED & M AINTAINED S HIFT I NSPECTIONS BY A C OMPETENT P ERSON E QUIPMENT I NSPECTION EVERY 12 M ONTHS S IGN P ERSON Q UALIFICATIONS O PERATION P ROCEDURES OF E QUIPMENT SUBPART CC