1 The ProMus Pump A New Direction in ProMinent Metering Pumps
2
Experts in Chem-Feed and Water Treatment 2 ProMus Training Sections Bridging the Gap Technical Review Sales Review
3
Experts in Chem-Feed and Water Treatment 3 Bridging the Gap Pumps Needed for Heavy Industrial Applications Sigma’s Not Always Suitable Hydro and Makro Only Partial Solution Need Higher Pressure Orlita is too Large and Specialized Need for API 675 General Compliance
4
Experts in Chem-Feed and Water Treatment 4 API 675 Key Points Removable Check Valves Spool pieces acceptable if proposed Adjustable Over Turndown While Running Rated for 110% of Maximum Specified Flow Steady State Flow of 1% Over 10:1 Turndown Flow Repeatability of +/-3% Connection Sizes ½” Through 1-½” (Really!) Double Check Valves When Specified
5
Experts in Chem-Feed and Water Treatment 5 API 675 Key Points Diaphragms Provisions to prevent excess flexure (Contour Plates?) Double Diaphragms when spec’d Internal Relief Valve Set at 10% or 25 psig Over Rated Pressure, Whichever is Higher Packed Plunger Pumps Require Ext. PRV Stroke Adjustment – Manual or Auto Visual indication of Stroke Setting for both Locking Device
6
Experts in Chem-Feed and Water Treatment 6 API 675 Key Points Special Tools (upon request) Hydrotest to 1.5x MAWP (Maximum Allowable Working Pressure) Repeatability and Linearity Test 100, 75, 50, 25, 10 Percent Up and Down (10 Point) Data and Documentation Requirements
7
Experts in Chem-Feed and Water Treatment 7 API 675 Specs You Don’t See Cast Iron Drive Case Stroke Speed Limitations Hydraulically Actuated Diaphragm Mechanically Actuated Diaphragm Restrictions on Lost Motion Control of Flow
8
Experts in Chem-Feed and Water Treatment 8 Technical Specifications Hydraulically Actuated Diaphragm Pump Capable of 0.61 gph to 101 gph Capable of Pressures to 3500 psig Mechanical Lost Motion
9
Experts in Chem-Feed and Water Treatment 9 Technical – ProMus Features Materials – 316ss Alloy 20, Hast C – future development Modular Design – Maximum Interchangeability 5 Gear Ratios 8 Plunger Sizes 3 Head Sizes (17, 30 & 40) 1 Drive Size Internal Pressure Relief (Adjustable) Mechanically Actuated Hydraulic Refill Valve Automatic Hydraulic Air Bleed Valve
10
Experts in Chem-Feed and Water Treatment 10 Technical – ProMus Features 10 Turn Micrometer Stroke Adjustment 10:1 Turndown Ratio on Stroke Nema 4 and Nema 7 Stroke Actuators Avail. Can Utilize Variable Speed Drives* Double Ball Check Options (17 & 30 Heads) Visual Indication of Relief Valve and Air Bleed Valve Operation
11
Experts in Chem-Feed and Water Treatment 11 Technical – ProMus Specifications Minimum Backpressure – 22 psig Maximum Suction Pressure – 50 psig Maximum Viscosity – 200 cps (500 cps w/ spring) Oil Quantity – 1.5 quarts Oil Type – Mobilube 1 SHC 70W-90 or equal Priming Lift – 5 ft Suction Lift – 7.5 ft Weight – approx. 50-72 lb w/o motor
12
Experts in Chem-Feed and Water Treatment 12 Technical – ProMus Specifications Operating Temp. Range – 15 to 105 F Maximum Process Fluid Temp Continuous – 195 F Intermittent – 250 F Permissible Humidity – 95% Non- Condensing
13
Experts in Chem-Feed and Water Treatment 13 Technical – Motors Need to Know Class, Division & Group Class – Gas, Vapor, Liquid or Dust Division – When Combustible is Present Group – Type of Combustible Material Explosion Proof Motors Class 1, Division 1 Class 1, Division 2 if Single Phase Power Be aware of Group required for motor
14
Experts in Chem-Feed and Water Treatment 14 Sales – ProMus vs mRoy Newer Pump Design Incorporates newer hydraulic refill technologies Will not fail on starved suction conditions Modular Simple to modify in field Easy to Hydraulically Prime Repairable Check Valves Very Price Competitive!!!!
15
Experts in Chem-Feed and Water Treatment 15 Sales – Applications Chemical Plants Catalysts for Process Additives for Plastics Defoamers Oil & Gas Refineries Oil or Fuel Additives Power Plants Water Treatment Boiler Feed Boiler Feed Applications O 2 Scavengers Anti-scalants Amines Phosphates pH Control LNG Plants Odorant (Mercaptan)
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.