Download presentation
Presentation is loading. Please wait.
1
Training
2
Terminology Port- The connection to the server or pc. On sateon pro this is always ip field network-a group of controllers connected to port usually on 485 line header- an Ethernet/485 converter unit that allows a line of 485 controllers to be connected to a pc Enclosure- a power supply unit that allows up to two controllers or one controller and one ip board to be mounted in it.
3
Sateon Pro Controllers
System Setup Part 1 - Hardware Cable Types Data Comms 485 Data Comms Ethernet Data Comms Sateon Pro Controllers 485 Ethernet Sateon Pro Enclosures
4
Line Header to Panel (Comms Converter)
Cable Types Line Header to Panel (Comms Converter) 2 Pair Belden (or equivalent) # m per Segment Cat 5 – Use Twists – Not for electrically noisy environments – 200m Panel to Reader See Reader Documentation 50m (if using Keypad Interface) External Inputs 2 Core Cable (Alarm) m Locks Use suitable gauge cable for current draw and volt drop Current Draw (Amps) x Distance (Meters) x Wire Resistance per Meter (Ohms) = Voltage Drop (Volts)
5
Data Comms 485 Data Comms SATEON PRO MINI PC Ethernet Door Controllers
6
485 Panels
7
10 Panels on a line maximum Max 1200m No T taps / loops
Sateon Pro 485 RS-485 Two wire (plus Ground) – 1 Pair 10 Panels on a line maximum Max 1200m No T taps / loops Each pair should be twisted All controllers will need an Ethernet Line Header
8
Ethernet Line Header Sateon Pro Line Header Can be mounted in standard Enclosure
9
Data Line Overview 485 Panels are Polled 1 2 3 4 ….. 10 Addresses do NOT have to be sequential PORT connects a SATEON Comms Engine to Panels SEGMENT - 1,200m length of Belden (2 or 4 wire) Field Network - Cable from LINE HEADER to last Panel 10 Panels - address range 1 to 63
10
Ethernet Panels
11
Sateon Pro Ethernet Panels are Polled and will immediately Synchronise with SATEON Each IP Panel has it’s own IP address and connects directly to the network via a RJ45 Plug
12
Panel decides to unlock the door (or not)
PRO485 vs PRO ETHERNET PRO 485 (Card Access) Present Card Panel decides to unlock the door (or not) Waits for next Poll from SATEON PRO Tells SATEON PRO about the card and access was allowed PRO ETHERNET (Card Access) Present Card Panel decides to unlock the door (or not) Tells SATEON about the card and access was allowed 485 (Input to Output on another Panel) Activate input on Panel 1 Panel 1 waits for next Poll from SATEON PRO Panel 1 tells SATEON PRO about the input activation SATEON PRO broadcasts to Panel 2 to activate the output PRO ETH (Input to Output on another Panel) Activate input on Panel 1 Panel 1 tells SATEON about the input activation SATEON broadcasts to Panel 2 to activate the output
13
Request To Exit contact must be N/O
Sateon Pro Panel Break Glass Monitoring Request To Exit contact must be N/O Break Glass Unit contact must be N/O
14
Sateon Pro Summary Intelligent Door Controller
485 TCP/IP 2 doors read in. 1 door read in/out Additional alarm input Card capacity 500 users Real-time processing at door LED and sounder outputs Memory buffer whilst off-line (4,000 Events) Upgrade flash whilst system is working Volt Free Changeover output for Locks Can be mounted in any PSU
15
Sateon Pro Controller Connections
16
Sateon Pro Lock Connections
17
Sateon Pro Reader Wiring
18
Sateon Pro Door Monitor Wiring
Door Sensor – Normally closed Door Sensor – Normally closed - Monitored Dual Door Sensor – Normally closed - Monitored
19
Request To Exit contact must be N/O
Sateon Pro Break Glass Monitoring Request To Exit contact must be N/O Break Glass Unit contact must be N/O
20
Sateon Pro Input Wiring
Input – Normally closed or Normally Open Input – Normally closed or Normally Open
21
AES Encryption on eSeries Real-time processing
Sateon Pro Input / Output IO RS485 TCP/IP AES Encryption on eSeries Real-time processing Memory buffer whilst off-line (4,000 Events) Upgrade flash whilst system is working 8in / 4out Can be mounted in any Enclosure
22
Sateon Pro Input / Output 485 & Ethernet
23
EZ Enclosures
24
Sateon Pro Mains Enclosure
2 x Sat Pro board or 1 x Sat Pro board and 1x IO board 1 x 7Ah Battery Built in tamper to lid Built in power supply (3A) with 2A available for external equipment, i.e. locks and readers
25
Sateon Pro Mains Enclosure
26
Sateon Pro POE+ Enclosure
2 x Sat Pro Panel or 1 x Sat Pro Panel & 1x IO board 1 x 7Ah Battery Built in tamper to lid Built in power supply with 2A available for external equipment, i.e. locks and readers POE 802.3af 44VDC 350mA 15.4W 900mA POE at 44VDC 1700mA 25.5W 2000mA
27
EZ POE Enclosure
28
IP Panel IP Panel IP Panel Sateon Pro Hardware Overview
Up to 10 x RS485 Panels
29
Q&A Were you listening??? Question 1 - How long can a segment of the Comms line be? Question 2 - What is the value of the EOL resistor that should be fitted to the beginning and end of the Comms line. Question 3 - How many cards does the Sateon Pro board hold? Question 4 – How many controllers does it support? Question 5 - Can you wire a Sateon Pro485 board to a Sateon Pro IP? Question 6 - How many Sateon Pro boards fit in an Enclosure? Question 7 - What is the max Amps available for locking in an Enclosure?
30
Add a eSeries (IP) Panel Update the Firmware in a Panel Add a Door
System Setup Part 1 - Software Install SATEON PRO Licence SATEON PRO Add a 485 Panel (I/O Board) Add an Input Add a eSeries (IP) Panel Update the Firmware in a Panel Add a Door Add a Reader Add a Person Add Access Add a Token Unlock a door
31
Must change password on first logon Can change to sateon if you wish
SATEON - LOGON Username : admin Password : sateon Must change password on first logon Can change to sateon if you wish
32
SATEON Main Screen
33
Visitors not included on Sateon Pro
SATEON Hubs Access Control Control Centre Reports Event Configuration System Configuration Visitors not included on Sateon Pro
34
Apply the licence Verify the licence Setup the Token Type
SATEON – Initial Tasks Apply the licence Verify the licence Setup the Token Type Setup the Site Name Setup the Comms Engine
35
Access Control – Token Management – Token Types - Add
SATEON – Create the Token Access Control – Token Management – Token Types - Add
36
Access Control – Device Management - Site – Main Site
SATEON – Create the Site Access Control – Device Management - Site – Main Site
37
SATEON Create the Comms engine
Access Control – Device Management - Comms Engine – Add
38
Will assign an address in 169.254.?.? Range if no DHCP available.
SATEON Programming Pro Devices IP Panel or Line Header. When supplied are DHCP. Will assign an address in ?.? Range if no DHCP available. Use the eSeriesDeviceProgrammer tool to set the IP address. Encrypted devices will not come on line until ‘seeded’ using the eSeriesDeviceProgrammer tool with access to a valid SATEON licence. eSeriesDeviceProgrammer will find devices in the same subnet and allow you to program them. eSeriesDeviceProgrammer can be run from (and set the encryption of an Ethernet device) from any SATEON client machine (Config required)
39
SATEON EseriesDeviceProgrammer.exe
40
SATEON
41
A 485 Panel wires to a Field Network
SATEON A 485 Panel wires to a Field Network Each field network has at least one Port, the Port is the physical connection between the LAN / WAN and the Field Network. A Field Network may have many Ports. A Field Network may have 10 Panels. Access Control – Device Management – Field Network– Add Access Control – Device Management - Port– Add Access Control – Device Management - Panel– Add
42
SATEON
43
SATEON
44
SATEON
45
Access Control – Access Management – Access Groups
SATEON Access Control – Access Management – Access Groups
46
SATEON Time schedules are used to define the periods during which things can happen within the SATEON access control system. For example; When access is permitted at certain doors When events are reported When actions can occur. A time schedule is set up as a combination of time patterns, where each time pattern defines one or more periods of time. Each individual period of time with a defined start and end time is an appointment. Appointments can consist of an entire day.
47
Update the Firmware in a Panel Add a Door Add a Reader Add a Person
Recap Install SATEON PRO Licence SATEON PRO Add a 485 Panel Add a PRO(IP) Panel Update the Firmware in a Panel Add a Door Add a Reader Add a Person Add Access Add a Token Unlock a door
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.