1 ELECTRONIC LOCK. 2 Content System Integrators, Locksmiths What is Smart Air? General Overview Design, functions and added values Features and benefits.

Similar presentations


Presentation on theme: "1 ELECTRONIC LOCK. 2 Content System Integrators, Locksmiths What is Smart Air? General Overview Design, functions and added values Features and benefits."— Presentation transcript:

1 1 ELECTRONIC LOCK

2 2 Content System Integrators, Locksmiths What is Smart Air? General Overview Design, functions and added values Features and benefits Applications Installation scheme

3 What is Smart Air? It´s autonomy access control systém which use RFID technology 13,56 MHz integrated into the front escutcheon Plate and battery powered. It can operate in 3 modes: 1/ Stand Alone 2/ Off line 3/ Update on Card (UoC) Benefits : the electronic parts integrated into the front and back shield battery operation –no cables, no lead covers – easy installation ideal for use with panic function mechanical locks user friendly product available in DIN and Scandinavian range, different distances and the others System Integrators, Locksmiths

4 4 ELECTRONIC LOCK This technology offers: Bigger information capacity and data protection Faster transmission speed Data encryption Universal applications – weding machines, pay cards, access cards, etc. Contactless Higher realibility As identification part can be used card, keytag, handrings, etc. Possibility to accomodate different technologies like magstripe, etc. kontaktní čip, apod. Very high mechanical and weather resistance. General Overview Supported Technologies: Identification Technology Mifare 13,56MHz Mifare (ISO 14443A) ST Microelectronics (ISO 15693) System Integrators, Locksmiths

5 5 ELECTRONIC LOCK Handle Electromechanical operation Proximity Card (MIFARE) Design, functions and added values Wiegand - 26bit format like an example of data storage d1 P18bit Facility code16bits IDP2 Facility code FC = 0 - 255ID = 16bitů 256 = 2 8 2 16 = 0 - 65535 System Integrators, Locksmiths

6 6 ELECTRONIC LOCK Design, functionsand added values narrow design for easy installation on various types of doors (incl. profile doors) Wide range of designs,colours and various compatible locks All access data stored in back part – data physically secured Design and function Security and Comfort Installation without cables and power supplies – full battery operation All electromechanical and electronic devices are placed in back side shield, only reader head is placed from the front side – burglary resistance Outside handle is movement free even if the lock is blocked (Scandinavian types has deadbolt projection actionfeature) Outside handle is movement free even if the lock is blocked (Scandinavian types has deadbolt projection actionfeature) Smart Air is compatible with any cylinders – emergency opening. System Integrators, Locksmiths

7 7 ELECTRONIC LOCK Design, functions and added values Available Designs: Versions: Long plate Short plate - rossete handle and cylinder cover Covers: Standard – for interior installation / clutch made from Ferrum Extreme – for exterior installation (water resistant) / clutchmade from stainless stell with washer Surface fininshes: Antique BrassPVD Polish Brass PVD Satin BrassStainless Steel System Integrators, Locksmiths

8 8 ELECTRONIC LOCK Design, functions and added values: Available Designs: Long Plate without cylinder Long Plate with cylinder Short Plate with cylinder Long Plate with hidden cylinder Short Plate without cylinder System Integrators, Locksmiths

9 9 ELECTRONIC LOCK Design, functions and added values: Handle Designs: U-shape handle for emergency exits acc. to EN179 Vector SenaXaraZafiraPomo System Integrators, Locksmiths

10 10 ELECTRONIC LOCK When the lock is locked from inside, electronic privacy is active. Opening is possible only with authorization card - green and red LED is lighting together when electronic privacy is active and card present. Features and Benefits What is Electronic Privacy? Function Electronic privacy is optional Electronic privacy without cylinderElectronic privacy with cylinder and thumbturn System Integrators, Locksmiths

11 11 ELECTRONIC LOCK Features Reading modul : Identification technology: 13,56MHz for read and write access of contacless cards - ISO 15693 or ISO 14443 A (more common) Reading distance:10mm Control unit EEPROM memory (data protection when batteries depleted) Up to 1.500 users and up to 1.000 events (Audit trail) Reálný time clock and calendar - 14 time zones with 5 time periods each Red and green warning LED Operation modes: Passage (free way), First User, Standard, Double User Battery module: Type of battery:3 x 1,5V LR03 AAA (alkaline batteries) Estimated battery life: More than 30.000 operations (3 -4 years) Everything under control Individual locking plan for each user Limited access according time zones Cancel lost or stolen credentials Identify all and every user Get Audit trails System Integrators, Locksmiths

12 12 ELECTRONIC LOCK Applications TS10 TS1000 TS1000 UoC (Stand Alone) (Off Line) (Update on Card) Licence Licence Licence ID card reading – no sector Sector reading– user can choose Sector reading– user can choose (Software + Data + Key) (Software + Data + Key) - Portable Programmer Portable Programmer - Encoder Encoder - - Updater Credentials Credentials Credentials Same HW for all management systems. Possibility to upgrade Stand Alone to OffLine and/or Update on Card without removing the lock from the door. System Integrators, Locksmiths

13 13 ELECTRONIC LOCK Applications: Stand Alone - TS10 Stand Alone - TS10 Kit contents: Licence Card –Programming Card- Mifare 1k Licence Card –Programming Card- Mifare 1k 25pcs of Mifare user cards 25pcs of Mifare user cards Emergency battery pack Emergency battery pack Programming is provided with presenting of Licence Card and after the user cards. System Integrators, Locksmiths

14 14 ELECTRONIC LOCK Applications: Stand Alone - TS10 Stand Alone - TS10 User registration: 1.Present the programming card (red card) 2.Present user´s card/cards for for registration into lock memory 3.Close the programming sequency – present programming card again (programming sequency is autamtically closed after 10s of no activity) System Integrators, Locksmiths

15 15 ELECTRONIC LOCK Applications: Stand Alone - TS10 Stand Alone - TS10 System Integrators, Locksmiths User erasing: 1.Present the programming card (red card) 2.Present user´s card/cards for for erasing from lock memory 3.Close the programming sequency – present programming card again (programming sequency is autamtically closed after 10s of no activity)

16 16 ELECTRONIC LOCK Applications: Stand Alone - TS10 Stand Alone - TS10 Lock Memory Delete: 1., 2. and 3. Present 3x programming card to delete the lock memory. System Integrators, Locksmiths

17 17 ELECTRONIC LOCK Applications: Emergency opening with battery pack: 1.When operating batteries are depleted - LED is blinking after user card presenting 2.Connect the battery pack through jack plug in into the antenna connector 3.Present user card, open the door and replace the operation batteries in the lock shield Stand Alone - TS10 Stand Alone - TS10 System Integrators, Locksmiths

18 18 ELECTRONIC LOCK Licence TS 1000 Software Program and locking plan maintanance - locking plan (DATA) - each locking plan has unique systém code Autorization key - encrypted authorization keyw with istallation systém code Portable programmer Dowlnload and upload of data into and from the locksEncoder: cards, keytags, etc. Updater (Update on Card System) On line wall reader Automatic information update - Audit trail - Modifications in Matrix Off line / Update on Card Applications: System Integrators, Locksmiths Easy to install and easy to use  Step 1Creation of the locking plan in the computer.  Step 2Download the information to the Portable Programmer.  Step 3Program the locks with the Portable Programmer.  Step 4Encode the credentials with the Smartair encoder.

19 19 Off Line System Components PP TS1000 Software Encoder Credentials (Mifare Classic) Electronic Locks ELECTRONIC LOCK System Integrators, Locksmiths

20 20 Off Line System Electronic Lock Credential System Code User ID / Time Zone / Issue Date & Time Time Zones Holidays DST Clock State Table Required Grant Name Audit Trail System Code User ID Activation / Expiration Date & Time Issue Date & Time Given Grant Names Software System Code Users Doors Time Zones Matrix State Tables Grant Names Data ELECTRONIC LOCK System Integrators, Locksmiths

21 21 Off Line System Software System Code Users User Name Group Expiration and Activation Dates Doors Door Name Group Time Zones (Optional) 14 Time Zones / 5 Periods of Time Calendar (Holidays) / DST Special Functions Grant Names State Tables ELECTRONIC LOCK System Integrators, Locksmiths

22 22 Off Line System Software Matrix Who – Where - When ELECTRONIC LOCK System Integrators, Locksmiths

23 23 Off Line System Electronic Locks TS1000 Software Portable Programmer Electronic Lock Matrix User ID1; Time Zone; Card’s Issued Date & Time User ID2; Time Zone; Card’s Issued Date & Time User ID3; Time Zone; Card’s Issued Date & Time (Up to 1.500) Time Zone 1 Time Zone 2 Time Zone 3 Time Zone 4 (Up to 14) Holiday 1 Holiday 2 (Up to 365) DST 1 DST 2 Clock (Date & Time) Audit Trail (Up to 1.000 events) System Code Operations with the Portable Programmer Initialise First Programming Update Download modifications in the locking plan Audit Trail Get the Audit Trail Stored in the lock Open Emergency Opening State Table Required Grant ELECTRONIC LOCK System Integrators, Locksmiths

24 24 Off Line System Credentials TS1000 Software Encoder Credential (Mifare Classic) User ID Activation Date & Time Expiration Date & Time Issued Date & Time Given Grant Names System Code Structure of credential For off line application only 1 Sector is needed. Sector Protection through Key A & Key B. Multi-application : Sector selection in the TS1000 Software. ELECTRONIC LOCK System Integrators, Locksmiths

25 25 Off Line System Architecture Elect. Lock Credential System Code User ID / TZ / Issue Date Time Zones Holidays DST Clock State Table Required Grant Name Audit Trail System Code User ID Act. / Exp. Date Issue Date & Time Given Grant Names Software System Code Users Doors Time Zones Matrix State Tables Grant Names PP TS1000 Software Encoder ELECTRONIC LOCK System Integrators, Locksmiths

26 26 Update on Card Just adding the updater... Elect. Lock Credential System Code User ID / TZ / Issue Date Time Zones Holidays DST Clock State Table Required Grant Name Audit Trail System Code User ID Act. / Exp. Date Issue Date & Time Given Grant Names Software System Code Users Doors Time Zones Matrix State Tables Grant Names PP TS1000 Software Encoder Updater On Line (TCP/IP) ELECTRONIC LOCK System Integrators, Locksmiths

27 27 Update on Card Step 1 Credential System Code User ID Act. / Exp. Date Issue Date & Time Given Grant Names Revalidation Software System Code Users PP TS1000 Software Encoder Updater On Line (TCP/IP) Updater Embedded PC (TCP/IP Connection) Reader Data on Credential Activation Date Expiration Date Given Grant Names Revalidation New feature to force the user to go to the Updater. Optional for each user. Revalidation Time defined for each user. ¡No need blacklist! ELECTRONIC LOCK System Integrators, Locksmiths

28 28 Update on Card Step 2 Credential Sector 1 System Code User ID Act. / Exp. Date Issue Date & Time Given Grant Names Revalidation PP TS1000 Software Encoder Updater On Line (TCP/IP) Audit Trail Get the User’s Audit Trail on the credential. Capacity depends on Mifare Card. Get the battery status on locks. Elect. Lock System Code User ID / TZ / Issue Date Time Zones Holidays DST Clock State Table Required Grant Name Audit Trail Battery Status. Sector 2 User’s Audit Trail Battery Status ELECTRONIC LOCK System Integrators, Locksmiths

29 29 Update on Card Step 2 Credential Sector 1 System Code User ID Act. / Exp. Date Issue Date & Time Given Grant Names Revalidation Memory Capacity 1 Event = 8 Bytes. Mifare 1kIn 1k3 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 6 (Events/Sector) x 13 (Sector/Card) = 78 (Events/Card) Mifare 4kIn 1k 3 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 6 (Events/Sector) x 13 (Sector/1k) = 78 (Events/1k) In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 6 (Events/Sector) x 13 (Sector/1k) = 78 (Events/1k) In 2k 15 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 30 (Events/Sector) x 8 (Sector/2k) = 240 (Events/2k) 78 (Events/1k) + 78 (Events/1k) + 240 (Events/2k) = 396 (Events/Card) Options in the software: Decide how many sectors are going to be used to store the User’s Audit Trail. When the selected memory capacity is full for each user we can decide: The card needs revalidation (to empty the memory) The last event delete the first one. Sector 2 User’s Audit Trail Battery Status ELECTRONIC LOCK System Integrators, Locksmiths

30 30 Update on Card Step 3 Credential Sector 1 System Code User ID Act. / Exp. Date Issue Date & Time Given Grant Names Revalidation Modifications in Matrix PP TS1000 Software Encoder Updater On Line (TCP/IP) Update Locks Update the user’s locking plan (Matrix) into the locks. Add new users. Elect. Lock System Code User ID / TZ / Issue Date Time Zones Holidays DST Clock State Table Required Grant Name Audit Trail Sector 2 User’s Audit Trail Battery Status 1 Change ELECTRONIC LOCK System Integrators, Locksmiths

31 31 Update on Card Step 3 Credential Sector 1 System Code User ID Act. / Exp. Date Issue Date & Time Given Grant Names Revalidation Modifications in Matrix Memory Capacity 1 Change requires 4 Bytes. Mifare 1kIn 1k3 (Block/Sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 12 (Change/Sector) x 13 (Sector/Card) =156 (Change/Card) Mifare 4kIn 1k 3 (Block/Sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 12 (Change/Sector) x 13 (Sector/1k) = 156 (Change/1k) In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 12 (Change/Sector) x 13 (Sector/1k) = 156 (Change/1k) In 2k 15 (Block/sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 60 (Change/Sector) x 8 (Sector/2k) = 480 (Change/2k) 156 (Change/1k) + 156 (Change/1k) + 480 (Change/2k) = 792 (Change/Card) Options in the software Decide how many sectors are going to be used to update the locking plan in the locks. Sector 2 User’s Audit Trail Battery Status ELECTRONIC LOCK System Integrators, Locksmiths

32 32 Update on Card Step 4 Credential Sector 1 System Code User ID Act. / Exp. Date Issue Date & Time Given Grant Names Revalidation Modifications in Locks PP TS1000 Software Encoder Updater On Line (TCP/IP) Update Locks (On study...) Update: Time Zones Calendar (Holidays & DST) State Table Required Grant Name Elect. Lock System Code User ID / TZ / Issue Date Time Zones Holidays DST Clock State Table Required Grant Name Audit Trail Sector 2 User’s Audit Trail Battery Status ELECTRONIC LOCK System Integrators, Locksmiths

33 33 Update on Card Updater PP TS1000 Software Encoder Updater On Line (TCP/IP) Phase 1 Embedded PC and reader in the same box. Door Control in another box. Door Control Embedded PC Reader Blocking Device Door ELECTRONIC LOCK System Integrators, Locksmiths

34 34 Update on Card Updater PP TS1000 Software Encoder Updater On Line (TCP/IP) Phase 2 Embedded PC and door control in the same box. Separate reader. Reader Embedded PC Door Control Blocking Device Door ELECTRONIC LOCK System Integrators, Locksmiths

35 35 Update on Card Updater Network Unlimited number of Updaters One Database Updater 1 Updater 2 Updater 3 Updater 4 Updater n Database Server ETHERNET TCP/IP ELECTRONIC LOCK System Integrators, Locksmiths

36 36 ELECTRONIC LOCK Installation Template System Integrators, Locksmiths

37 37 ELECTRONIC LOCK InstallationTemplate System Integrators, Locksmiths

38 38 ELECTRONIC LOCK Installation Template System Integrators, Locksmiths

39 39 ELECTRONIC LOCK Installation Template SmartAir shileds Outside shiled dimensions 40,5 x 281 x 10mm. Inside shield dimensions 40,5 x 281 x 21mm. Material Stainless Steel Lock mortise Compatible with DIN and Scandinavian locksin different distancies. Door width From 38mm to 110mm door width. The follower lock will have different lengths acc. to the door width. See the XLS file. It´mandatory to provide the dimensions X and Y. System Integrators, Locksmiths