1 TEAM II Reboiler Energy Performance By: Cortez Rankin & D. Caruthers 11/4/03 ENCH/ENEV 435

2 Objectives To provide Transient Analysis of the Reboiler Energy

3 Distillation Column

4 Q in =2750

5 Distillation Column Q in =2750 Q loss

6 Reboiler M cw = 6.5 kg T reboiler T Room Q in = 2750 W Q loss

7 Reboiler Data dT( o C)/dt(min) = 3.8

8 is calculated data wise and graphically C p is looked up in a handbook M cw and Q in are measured Now we can determine Q loss M cw = 6.5 kg Q in = 2750 W Q loss

9 Reboiler Data Q in = 2750 W

10 Reboiler Data

11 Heat Loss of Reboiler A = 2*π*r*l + 2*π*r 2 Surface Area (A) = 0.44 m 2 found by measuring Reboiler Measure T reboiler and T room (23 o C) Determine U… the heat transfer coefficient

12 T reboiler T Room Q in Q loss Area = 0.44 m 2

13 U mean is 51 W/m 2 - o C Standard deviation with a confidence level of 95% is ± 8 W/m 2 - o C T room = 23 o C A = 0.44 m 2