REMODECE Project: WP4: Measurement / Surveying Campaigns status Markogiannakis Georgios Centre for Renewable Energy Sources Department for Energy Policy Analysis CRES ΚΑΠΕ 4 th REMODECE project meeting Coimbra, September 2007
2
REMODECE – WP4 Surveying Campaign CRES ΚΑΠΕ 400 Questionnaires distributed to consumers 60 Monitoring Campaign 90 Surveying Campaign 1 st round by e-mail (140 questionnaires) limited feedback (10% returned) Door-to-door (60 questionnaires) Better results (67% returned) Uploaded to CRES website (15 questionnaires received)
3
REMODECE – WP4 Monitoring Campaign CRES ΚΑΠΕ 62 Households (DIACE system) Monitoring applied to: TVs (62) TV peripherals as sets (DVD players, amplifiers, decoders…) (60) Audio (Hi–Fi) (40) Computer sites (55) Most common used lamps (6-10 per household) Air – condition (17 households) Stand – by consumption Recorded individually for each appliance [I (A), V (V), cos(φ)]
4
REMODECE – WP4 Monitoring Campaign CRES ΚΑΠΕ Recording of the indication on the utility meter Start of monitoring End of monitoring Restrictions due to metering equipment For more detailed monitoring For more houses
5
REMODECE – WP4 Monitoring Campaign CRES ΚΑΠΕ Changes to the metering format Aa aa aa to aa aa E.g. in case of 2 computer sites in a household (05 00 – 05 01) Changes will be made with respect to the database format Lamp metering Almost 15% of data are lost Due to software errors
6
REMODECE – WP4 Problem areas Questionnaires E-mail Limited feedback Door-to-door Time restrictions (is not time effective) Monitoring 15% error to lighting measurements Restrictions due to limited amount of metering equipment (details, number of monitored houses) CRES ΚΑΠΕ
7
REMODECE – WP4 Data Management §Databases l Appliances l Lighting Data available in text files CRES ΚΑΠΕ
8
REMODECE – WP4 Data processing (examples) §Error correction l Errors returned by the system l Manual correlation §Charts l Average total electricity consumption (2 week period, 15 houses) CRES ΚΑΠΕ
9
REMODECE – WP4 Data processing (examples) §Charts l Stand-by consumption compared to the energy consumed by the monitored appliances (15 houses) 22,1 % stand – by of the monitored appliances 3% of the total consumption CRES ΚΑΠΕ
10
REMODECE – WP4 Data processing (examples) Charts l Comparison of the energy consumed to different types of equipment (15 houses) CRES ΚΑΠΕ
11
REMODECE – WP4 Data processing (examples) §Pie charts for each household CRES ΚΑΠΕ
12
REMODECE – WP4 Data processing (examples) §Air – condition CRES ΚΑΠΕ
13
REMODECE – WP4 Data processing (examples) §PC consumption CRES ΚΑΠΕ
14
REMODECE – WP4 Data processing (examples) §TV consumption CRES ΚΑΠΕ
15
Thank you for your attention! Centre for Renewable Energy Sources 19 th km Marathonos Ave, Athens HELLAS CRES ΚΑΠΕ 4 th REMODECE project meeting Coimbra, September 2007