COST286 meeting Barcelona 14/15 April 20051 BUTE Part 1 Conducted and radiated disturbance regulations for PLC devices János Löcher; György Varjú BUTE BUTE Part 2 Site Trial using the low voltage feeder of RBS sited on HV power line tower EPFL Part 3 Mitigation of electromagnetic field radiated by PLC systems (in indoor environment) EPFL
2
COST286 meeting Barcelona 14/15 April 20052 BUTE Part 1 Conducted and radiated disturbance regulations for PLC devices
3
COST286 meeting Barcelona 14/15 April 20053 IEC-61000-3-8 Signaling on low voltage electrical installations No radiated interference limits apply below 30 MHz Limits of mains terminal interference voltage
4
COST286 meeting Barcelona 14/15 April 20054 CLC/prTS50437:2004 Draft Technical Specification for electromagnetic emissions fromaccess powerline communications networks Limits of conducted common mode (asymmetric mode) disturbances at network cables Limits of radiated disturbances from networks cables
5
COST286 meeting Barcelona 14/15 April 20055 ITU-T K.60 Emission limits and test methods for telecommunication networks Limits for unwanted disturbance emissions from telecommunication networks No conducted interference limits apply
6
COST286 meeting Barcelona 14/15 April 20056 H-field limits converted to E-field using the far field correction of 51.5 dB
7
COST286 meeting Barcelona 14/15 April 20057 BUTE Part 2 Site Trial using the low voltage feeder of RBS sited on HV power line tower
8
COST286 meeting Barcelona 14/15 April 20058 Site Trial using the low voltage feeder of RBS sited on HV power line tower
9
COST286 meeting Barcelona 14/15 April 20059 HE Modem Signal injection Radiated field metering Measuring concept 3 phase Low Voltage feeder PVC insulated phase conductors wounded around a bare neutral
10
COST286 meeting Barcelona 14/15 April 200510 Coupling PLT HE: (capacitive, inductive) - one, two or three phase to neutral - phase to phase - any other combination PLT Modem: (only capacitive) - only phase to neutral Used frequency Upstream:13.8 – 16.3 MHz (512 carrier) Downstream:19 – 22.8 MHz (768 carrier) Injected signal level max. 30 dBm Data transfer rate Downstream:max. 27 Mbps Upstream:max. 18 Mbps System overview
11
COST286 meeting Barcelona 14/15 April 200511 Characteristics to be measured K-factor measurement - H-field - Noise floor - Injected signal Ingression Noise LCL, TCL measurement - CM current Attenuation characteristics measurement Assessment of a technique to mitigate electromagnetic radiation from PLC Note: Regarding the measuring procedures, see: (JTA) “EMC analysis of LF unstructured telecom networks”
12
COST286 meeting Barcelona 14/15 April 200512 EPFL Part 3 Mitigation of electromagnetic field radiated by PLC systems (in indoor environment)
13
COST286 meeting Barcelona 14/15 April 200513 Mitigation of emissions V comp + - I comp - + V PLC I PLC E PLC =V PLC h PLC (f) h PLC (f) E comp =V comp h comp (f) h comp (f) V comp h comp (f)= -V PLC h PLC (f) ? V comp =-V PLC h PLC (f) h comp (f) Injection of an auxiliary compensation signal)
14
COST286 meeting Barcelona 14/15 April 200514 Classical Coupling of PLC Signals
15
COST286 meeting Barcelona 14/15 April 200515 Antenna mode and TL mode Currents
16
COST286 meeting Barcelona 14/15 April 200516 Mitigation u Idea: inject an auxiliary signal S 2 into the line formed by the ground and the neutral conductors u The auxiliary signal S 2 has the same amplitude and waveshape as the original PLC signal S 1, but with opposite polarity
17
COST286 meeting Barcelona 14/15 April 200517 Proposed Coupling: Power Splitter
18
COST286 meeting Barcelona 14/15 April 200518 Bidirectional Data Transmission
19
COST286 meeting Barcelona 14/15 April 200519 Test Configurations
20
COST286 meeting Barcelona 14/15 April 200520 Measurements
21
COST286 meeting Barcelona 14/15 April 200521 Measurement Results