Download presentation
Presentation is loading. Please wait.
1
SOFC PFD
2
Fuel Preparation
3
Desulfurizer (DS-101) 2 ppm H 2 S in natural gas feed H 2 S removed in DS-101 with disposable carbon filters 10% of CH 4 fed to combustor 90% of CH 4 fed fuel humidifier
4
Fuel Humidifier (FH-102) 1.25 Kmol H 2 0 per Kmol CH 4 fed to FH-102 Heat provided from combustor exhaust
5
Fuel Preheater (HX-103) Heat provided from fuel cell exhaust
6
Reformer (R-104) Equilibrium determined to be: –85% CH 4 → CO –15% CH 4 → CO 2 CH 4 + H 2 O → CO + 3H 2 CH 4 + 2H 2 O → CO 2 + 4H 2 Heat provided from reaction in combustor
7
Combustor (COMB -105) Extent of reaction for combustion assumed to be 100% CH 4 + 2O 2 → CO 2 + 2H 2 O Necessary O 2 provided from fuel cell air exhaust
8
Air Handling and WGS 226
9
Cathode Recuperator (HX-221) Heat provided by combustor exhaust
10
Water Gas Shift (WGS-222) CO + H 2 O → CO 2 + H 2 Equilibrium determined to be:
11
Air Preheater (HX-223) Heat provided by water gas shift exhaust
12
Air Compressor (COMP-224) Air intake for the system 6.65 standard cubic meters per minute flow
13
Solid Oxide Fuel Cell
14
Solid Oxide Fuel Cell (FC-331)
15
Post Processing
16
Water Purifier (WP-441)
17
Pressure Swing Absorber (PSA-442)
18
Anode Condenser (HX-443)
19
Water Pump (P-444)
20
PSA Compressor (COMP-445)
21
Chiller (Ref -446)
22
Hydrogen Compressor (COMP-447)
Similar presentations