Download presentation
Presentation is loading. Please wait.
1
1 Sachs et. al. IEEE Trans. Nuclear Science NS-31, 1249 (1984) Threshold Shift vs Gate Oxide Thickness Hole removal process by tunneling in thin-oxide MOS Structures Book. Timothy R Oldham “Ionizing Radiation Effects in MOS Oxides” 1999 World Scientific ++++ ++++ ++++ ++++ ++++ ++++ Si SiO 2 e--e-- e -- Poly- Si Gate Tunneling Region Dosage = 150 Krads
2
2 Company Device Oxide Thickness nm Dose before Damage seen Observation Damage Mode IHPA ASIC custom553 Mradslight damage XYSemi FET 2 amps752 MradMinimal damage XYSemiXP506212.344 krad Loss of output voltage regulation TI TPS546202023 kradabrupt failure IntersilISL 8502unknown40.6 krad Increasing input current IRIR3822unknown139 krads Increasing input current IRIR38419 & 2513 krads Loss of output voltage regulation STST1510unknown125 krad Loss of output voltage regulation EnpirionEN5365585 krad Increasing input current, EnpirionEN53825111 krads Loss of output voltage regulation Enpirion EN5360 #25100 MradsMinimal damage Enpirion EN5360 #3548 MradsMinimal damage
3
3 Found out at Power Technology conference 0.25 µm Lithography Irradiated Stopped on St. Valentines Day 2007 We reported @ TWEPP 2008 - IHP was foundry for EN5360 Enpirion EN5360 With Integrated Inductor
4
4 Twepp Nagos
5
5
6
6
7
7 For Purchasing EN5360: Steve Robb (908) 894 -6083 srobb@enpirion.com Tom Howell (908) 894-6029 thowell@enpirion.com Is there a Commercial product available ? Yes = It is the EN5360 Satellite folks are using it now sLHC Levels – 100 Mrads Use for voltage ratio = 4 Work at Super LHC levels for Tracker 5.5 V in > 1.3 out Enpirion is still supplying these to a very large customer IHP foundry will make it for many years. Can purchase in Die form for use with Air coil
8
8 Power Supply VInput 5.5 V max to prevent damage. GND Buck Regulator Eval Board Size = 3 inch x 3.5 inch Banana Jacks / Solder Wires Satish Dhawan, Yale University Load Resistor = 0.3 to 1.5 Ώ Line Drop ~ 0.25 volts @ 6 amps in each Leg ??? Twisted Pair Preferred V Input Monitor. 2 Wire Differential V Output Monitor 2 wire Differential Agilent 34970A & Multiplexer 33901A to Monitor I & V April 21. 2008 DC-DC Regulator Setup for Radiation Exposure GND V Output = 1.5 V. 1 to 5 Amps. ~ 0.5 Amps. V out > 5 – 20 Volts 4 Wire Current shunt V Output Monitor 2 wire Differential 4 Wire Current shunt V Output Monitor 2 wire Differential DC-DC Converter Voltage ratio = 8/10 Load: Rated Current or maximum without cooling ~ 1 amp Setup for 4 EVAL Boards Measure Bias Current with Load disconnected Solder all wires ???? Switch on/off