Download presentation
Presentation is loading. Please wait.
1
UIC – Physics Department Fast Timer Project Bob Dysert, Alan Bross - Fermilab November 18, 2005
2
f Fermilab MICE Simple in theory
3
f Fermilab MICE Muon cooling is needed to fit a beam into accelerator Need fast timing measurement to tag muons in RF bucket for acceleration Initial design: RF=805MHz required 10ps resolution Revised design: RF=201MHz requires only 50ps resolution
4
f Fermilab Fast Timer Operation f Fermilab Particles pass through radiator (MgF 2 ) Cerenkov light converted to electrons in photocathode (CsI) Electrons hit high gain MCPs Output of MCPs is collected on 50Ω anode Anode output is read out on fast oscilloscope or superconducting TDC TDC operation requires two detectors: one start, one stop
5
f Fermilab Fast Timer Readout Digital Tektronics oscilloscope 10GS/s, 3GHz, 4-Ch Superconducting TDC with 3-5ps per bin (never received)
6
f Fermilab Hardware Setup f MCP Stack MgF 2 Radiator CsI Photocathode UHV Enclosure 50Ω Anode SMA Feedthrough Particles
7
f Fermilab System Potentials Flange=GND Anode= -100V MCP Out= -1kV MCP In= -3.1kV PC = -4.1kV
8
f Fermilab MCP Performance G = 2E8 w/ Z-stack
9
f Fermilab Mechanical Setup f HV Feedthrough Baseplate Threaded Rod Ceramic Spacers HV Wings MCPs MgF 2 WindowSpring Loaded Top Plate Anode
10
f Fermilab Mechanical Setup - Baseplate
11
f Fermilab Mechanical Setup - Baseplate
12
f Fermilab Mechanical Setup - Anode
13
f Fermilab Mechanical Setup - Anode
14
f Fermilab Mechanical Setup – MCPs
15
f Fermilab Mechanical Setup – Photocathode
16
f Fermilab Mechanical Setup – Complete
17
f Fermilab Vacuum System Roughing Pump Leybold TMP50 Gate Valve Ceramic Isolation Vacuum Can Heat Tape Cold Cathode Gauge Quartz Window
18
f Fermilab Vacuum System Cold Cathode Readout Xenon Pulser APD for Trigger Scintillator Paddles PMTs Heating Tapes Detector HV Cables Bleed-up Valve
19
f Fermilab Problems Poor vacuum –Source: Quartz window leak –Source: MCPs outgassing –Source: Gas trapped? –Souce: Dirty components –Solutions: Plug leak, Bake out, Score screws, and clean.
20
f Fermilab Problems Arcing w/o MCPs in stack –Source: Wings arc to grounded threaded rod –Solution: PC potential = rod potential Arcing w/o MCPs in stack –Source: Threaded rod arcing to grounded vacuum flange –Solution: Solder threaded rod/nuts to prevent movement and eliminate sharp edges
21
f Fermilab Problems – Cont’d Breakdown w/ MCPs –Source: Resistance mismatch between MCPs in stack –Solution: Match MCPs No apparent signal –Source: Photocathode had degraded –Solution: Transport and assemble only in N 2 environment
22
f Fermilab Signals
23
Signals
24
Signals
25
Signals 1 st PE 2 nd PE Data from Xe UV Pulser (193 nm) G ≈ 2E7 1 st and 2 nd PE clearly visible
26
f Fermilab Questions? f bross@fnal.gov rdysert@fnal.gov
27
f Fermilab TDC Channel 2ps resolution with analog prescale
28
f Fermilab Thin MgF 2 radiator (Head-on as viewed by beam) –CsI Photocathode Fast Timing - Cerenkov Detector
29
f Fermilab Fast Timing Cerenkov Detector Wavelength region 120 - 200 nm –Cos c = 1/ n –For 5 mm radiator t = 3 ps ( not weighted for dn /d ) –For CsI PC expect 70 pe Anderson, Kwan, Peskov - Solid CsI PC Lu, McDonald – Semi-Transparent PC