Presentation is loading. Please wait.

Presentation is loading. Please wait.

Safecom's proven patented SYNERGY-2, DPSV4, Power Booster & Dual T-former P.S turns existing CATV networks into a super power synergy platform that provide.

Similar presentations


Presentation on theme: "Safecom's proven patented SYNERGY-2, DPSV4, Power Booster & Dual T-former P.S turns existing CATV networks into a super power synergy platform that provide."— Presentation transcript:

1 Safecom's proven patented SYNERGY-2, DPSV4, Power Booster & Dual T-former P.S turns existing CATV networks into a super power synergy platform that provide most reliable and economic powering system for unlimited backup time. Safecom Smart Grid Patented technology providing complete set of unlimited backup Power for CATV networks & Without Batteries DPS v4 Power Booster 4G SYNERGY-2 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv Dual T-former 2X 15A 60,66,72,87 V + DOCSIS Monitoring 1

2 Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the SYNERGY-2 & DPS4 draws power from the distant available source over existing coax or power cables. Utilizing breakthrough direct AC/AC On-Line stabilize technology safecom's SYNERGY-2 and Power Booster ensures an optimal voltage level – even over long distances. The Backup Power concept. Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 2

3 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the DPSv4 draws power from the nearest available source over existing coax or power cables. Safecom's proven smart grid technologies greatly improve network powering reliability while creating significant savings on both capital and operational expenses. 1 2 3 4 Power + Signal To remote / Node / Amplifier Optical Node/Trunk amp P.S 2 1 3 4 AC 1 input. AC 2 input Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) US PATENT 5747888 EP 0708559 3

4 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv  MINIMIZE THE NUMBER OF POWER SUPPLIES IN THE NETWORK.  INCREASING THE POWERING AREA COVERED BY POWER SUPPLY Vin 30-87Vac (US) Vin 30-64Vac (EU ) t v t v Vout 87 Vac (US) Vout 60 Vac (EU) US PATENT 8,415,822 Utilizing patented breakthrough direct on-line zero crossing AC/AC stabilize technology safecom's ensures an optimal voltage level to Optical Nodes & Line Amplifiers even the source of power from over long distances. Passive, Standalone element, power booster solves the power distribution problem in a CATV network caused by high-resistance and low energy efficient coax & electricity cables. 4

5 Power Booster – the 4G Transmission Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 5

6 All in One two-way RF Pass 1GHZ passive device that “toggle” available power between two distant locations. Redirecting power from the "normally" remote powered area to the area subject to power outage. During the normal mode of operation, when there is no power outage at either end of the pair, the SYNERGY-2 act as power block to the other side. Utilizing breakthrough step-up & stabilizing voltage technology the unit provides optimal & stable voltage level from local or remote P.S even from very long distance or using a un-stabilized P.S. Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv = DPS V 4 Power Booster US PATENT 8,415,822 AC 1 input. AC 2 input Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) 1 2 3 4 Power + Signal To remote / Node / Amplifie r Optical Node/Trunk amp P.S 21 34 + 6

7 Inputs/ Outputs configuration Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv Monitoring Inputs/outputs ONLINE Current & Voltage + status. AC 2 - InputAC1 - Input RF / AC 5-1000MHz 15A OUTPUT To Local Amplifier / Node RF / AC 5-1000Mhz 15A INPUT / OUTPUT To / From Remote Amplifier / Node US PATENT 8,415,822 Vin 30-87V Vac (US) Vin 30-64V Vac (EU ) t v t v Vout 87 Vac (US) Vout 60 Vac (EU) Inside view : SYNERGY-2 60/87V -2x15A 7

8 SYNERGY 2 the New generation. Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 8

9 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv US PATENT 8,415,822 NEW UR – Ultra Range +/- 25% Vin    a a a a a a 9

10 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv DOCSIS® & EuroDOCSIS Status Monitoring Embedded Transponder. Direct RF connection to CATV network Output 2 60,66,72 15A Output 1 60,66,72 15A External Monitoring DPS, SYNERGY-2 & more Dual Port P.S model SC-D-TFPS-1800-E-O-M 2 ports X 15A 60,66,72Vac 50/60 Hz. Direct connection. Voltage testing points Current loop testing points (For Clamp meter) 10

11 SYNERGY-2 Typical configuration Optical node + Trunk amplifier (or second optical node). Power + Signal From Optical node 4 21 3 1 2 3 4 AC 2 input. AC 2 input Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal Optical Node 21 34 To remote / amplifier / Node P.S.S P.S 60V Trunk amplifier Or Optical Node 60V Area A Area B Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 11

12 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv From Optical node 1 2 3 4 AC 2 input. AC 2 input Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal Optical Node 21 34 To remote / amplifier / Node P.S.S P.S SYNERGY-2 – Demo backup power from Area A to Area B Power + Signal Trunk amplifier Or Optical Node 60V 55V 50V 45V 60V Area A Area B 21 4 3 3 40V 60V 60V40V 12

13 Power + Signal To Optical node 4 21 3 1 2 3 4 AC 2 input. AC 2 input Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal 21 34 From remote amplifier / Node P.S.S P.S Optical Node 45V 50V 55V 60V Trunk amplifier Or Optical Node SYNERGY-2 – Demo backup power from Area B to Area A P.S Area A Area B Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 40V 60V 40V 60V 13

14 SAFECOM’s powering system around the world Reliability since 1994 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 14

15 15 Power backup Comparisons Synergy-2 / DPS V4 GeneratorsNon Standby Standby + Batteries Power Type Low HighLowHigh Cost Zero PermanentNegligiblePermanent Maintenance Unlimited Limited by fuelNone2 to 3 hour (Depends on batt. condition ) Backup Power Low cost Very expensive LowVery Expensive Redundant/ Diversity Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv

16 Typical optical network powering examples Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 16

17 90V-network 60V-available Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 17

18 60V-network 90V-available Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 18

19 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 60V-network 90V-available HFC Network DPS4 power backup 19

20 Business case. Improving customer service and satisfaction. Enabling MSO to add new services that required top high reliability. Unlimited backup time. Reducing dramatically CAPEX & OPEX. Increasing powering efficacy & save energy. Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 20

21 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv Complete Tree-View Import using CSV file Also can discover One node at a time from the UI (on –demand discovery ) Network discovery Export the Tree-View for further Use 1.Discovery can be backed up 2.Automated Full Topology DPS/ SYNERGY back up Auto Discovery of the PS Monitor Supports any device that has a SCTE-HMS-PS-MIB Supports auto discovery of thresholds (SCTE-HMS-COMMON-MIB ) Auto Generates Attribute Widgets with properly formatted thresholds Supports all Adjacent devices like APC, Cordex Controllers etc. Supports Discrete Thresholds DOCSIS® & EuroDOCSIS Status Monitoring 21

22 Monitors the Attributes – Pre-Configured Poll Interval – Summarization ( Hourly, Daily ) – Graphing ( Single or Multiple attributes ) – Attribute Refresh ( on demand ) Monitors the Current Alarm Table – Generates the Events from this table – Auto Correlation ( If the alarm is pre-existing, does not generate a new Alarm) – Updates the Tree-view with corresponding Severity – If SNMP Traps are enabled, It will auto-correlate the incoming traps with Current Alarm table 22

23 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv Google Maps Integration 23

24 ON-LINE REPORT 24

25 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv  Europe 60V & US 90V Standard.  Support full 15A rms input /output.  Prefect voltage at the remote location in the network.  †† Water-proof Enclosure.(IPX8)  Opposite connection protected.  †† Input & Output Surge Protection.  DOCSIS® & EuroDOCSIS Status Monitoring.  Online RF transmission during operation. (INTERNET,VOD,VOIP) Standard Features    25

26 Summery SAFECOM SYNERGY-2 & DPSv4 offers CATV operators the most efficient and reliable complete backup solution for unlimited time at minimum cost. No additional cost for MSO further to the fact that SYNERGY-2 / DPS v4 unit can be reuse from HFC network to full optical network. Following the government regulation for full powering backup. SYNERGY-2,DPSv4 & Power Booster systems enabling additional backup from remote powering. No maintenance. Unlimited life time. Two way powering on a single cable (Coax or electrical cable) Full DOCSIS® & EuroDOCSIS Status Monitoring Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 26

27 Thank you Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail david@safecom.tv 27


Download ppt "Safecom's proven patented SYNERGY-2, DPSV4, Power Booster & Dual T-former P.S turns existing CATV networks into a super power synergy platform that provide."

Similar presentations


Ads by Google