Flow Meter Installation
& Application Considerations
10
Sage Flow Meter Perfectly Designed Perfectly Built
Take One - Sage Flow Meter Perfectly Designed Perfectly Built Perfectly Calibrated
11
Add in – B llat a d sta → In ion
12
Your Customer’s reaction
15
ooooooo…make it go away!
16
You gotta be kidding!
17
HAPPY CUSTOMER
18
Good Job Dude!
19
Application Considerations
BASIC THEORY of FLOW STRAIGHT RUNS CONDITIONS TO AVOID INSERTION vs INLINE METERS FLOW CONDITIONING
20
CALIBRATION CONDITIONS
Basic Theory IN A PERFECT WORLD FIELD CONDITIONS EQUAL CALIBRATION CONDITIONS
22
APPLICATION CONDITIONS
GAS CONSTITUENTS NON-CONDENSING PIPE ID TYPE OF PIPE UPSTREAM STRAIGHT RUN PROBE INSERTION DEPTH
23
PIPE SIZE GAS UPSTREAM STRAIGHT RUN INSERTION DEPTH
24
PIPE SIZE As ordered and calibrated? Correct Pipe Schedule?
Correct for Velocities? GAS UPSTREAM STRAIGHT RUN INSERTION DEPTH
25
GAS PIPE SIZE Correct Gas? Correct % Constituents?
Moisture/Particles Present? UPSTREAM STRAIGHT RUN INSTALLATION DEPTH
26
UPSTREAM STRAIGHT RUN PIPE SIZE GAS Disturbances Multiple Disturbances
Fully Developed Flow INSTALLATION DEPTH
31
Velocity Profile in a River
35
PIPE SIZE GAS UPSTREAM STRAIGHT RUN INSTALLATION DEPTH
37
Velocity Profile in a Pipe
38
INSTALLATION DEPTH Center Probe in Pipe Page 15 Sage Prime Manual
39
Straight Run Requirements
Elbows Valves Expansions Reductions
40
FLOW CONDITIONING
45
Captive Flow Conditioners
46
Captive Conditioners Installed
47
Straight Run Requirements
DISTURBANCES WITHOUT CONDITIONING WITH SAGE CONDITIONING
48
90o Elbow Effect on Velocity Profile
49
Straight Run Requirements
One 90° Elbow W/O CONDITIONING 15 to 25 WITH CONDITIONING 3
50
Two 90o elbows – same plane
51
Straight Run Requirements
Two 90° Elbows in the same plane – within 3 diameters W/O CONDITIONING 20 to 36 WITH CONDITIONING 5
52
Two 90o elbows different planes
53
Straight Run Requirements
Two 90° Elbows in different planes – within 3 diameters W/O CONDITIONING 40 to 62 WITH CONDITIONING 9
54
4 to 1 reduction
55
Straight Run Requirements
Reduction in flow area (4/1) W/O CONDITIONING 15 to18 WITH CONDITIONING 3
56
4 to 1 expansion
57
Straight Run Requirements
Expansion in flow area (4/1) W/O CONDITIONING 30 to 84 WITH CONDITIONING 10
63
PIPE SIZE GAS UPSTREAM STRAIGHT RUN INSTALLATION DEPTH
68
ACFM vs SCFM Reference Conditions Pressure and Temperature effects
69
PRESSURE = 1 ATM 1 SCFM (1 ACFM)
70
PRESSURE = 2 ATM 2 SCFM (1 ACFM)
71
PRESSURE = 3 ATM 3 SCFM(1ACFM)
72
PRESSURE = 4 ATM 4 SCFM(1ACFM)
73
Electromagnetic & Radio Frequency INTERFERENCE (EMI / RFI)
74
Cummins Gen-Set VFD Walkie Talkie
75
Conducted EMI / RFI INTERFERENCE Signal Wires (4-20mA) Power Cables
Ground Connections Typical Solution: Ferrite Beads
76
EMI / RFI INTERFERENCE Coupled Components with mutual impedance
Can occur between two circuits that are not normally connected.
77
EMI / RFI INTERFERENCE Radiated Openings of any kind in Enclosures
in Conduits or Cables Typical Solutions: 1) Metal Enclosure 2) Shielded cable or conduit
78
EMI / RFI INTERFERENCE Best Avoided by using →
1) Metal Enclosures with CE Approval a) Prime b) Rio 2) Shielded conduits 3) Ferrite Beads
79
GAS CONSTITUENTS NON-CONDENSING PIPE ID TYPE OF PIPE
Application Summary GAS CONSTITUENTS NON-CONDENSING PIPE ID TYPE OF PIPE UPSTREAM STRAIGHT RUN PROBE INSERTION DEPTH