Download presentation
Presentation is loading. Please wait.
Published byClaud Price Modified over 9 years ago
1
EL SCADA Components Rad Tests EL SCADA components Radiation Resistance Tests Typical US/RE system components
2
Typical US/RE installation: –RTU: CLP500E EFACEC Advantech Diskless board Power Supply module, 48VDC Supply –DAU, 48VDC Supply CPU/Communication: MAP3200 Prometheus Input MAP3020, Output MAP3050 Analogues MAP3080 –IED, DIRIS Ap, 48VDC Supply (Low Voltage Switchboards) –Adapters, 24VDC Supply ADAM 4520: RS232/RS485 Switch MOXA EDS308 ELECDAN Power Converter 48/24VDC ELECDAN Pt100/10V Converter ELECDAN Counter/10V Converter (Ackerman Battery Measurement) Acquisition of Voltage Relay EL SCADA Components Rad Tests
3
Monitoring: –Remote Desktop Connection to connect to RTU CLP500 Version 5.1.0 managing the system Daily Control execution in List Mode –Automatism (Fung function) Return on Input board makes events & Alarm Reaction in case of failure (SEE) –Remote Reboot RTU level (if RDC & ping failure) DAU level (if IEC-Down & Win 3200 failure) 24VDC convertor (Switch, ADAM4520, ELECDAN convertors) DIRIS module (if Communication or measurements lost) EL SCADA Components Rad Tests
4
Power Supply 230/48VDC 6Amp Power Supply 230/48VDC 6Amp Ethernet GPN Ethernet GPN Remote Reboot Remote Reboot RT RR 230VAC 48VDC Jbus/RS485 Win3200/RS232 870-5-104/TCP/IP Remote Desktop Connexion RR 24VDC RTU CLP500E DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 ADAM 4520 RS232/RS485 ADAM 4520 RS232/RS485 DIRIS Ap ELECDAN Counters ELECDAN Counters ELECDAN Pt100 ELECDAN Pt100 ELECDAN Converter 48/24VDC ELECDAN Converter 48/24VDC Switch SPHINX EDS308 Switch SPHINX EDS308
5
RTU CLP500E DIRIS Ap RTU CLP500E Switch SPHINX EDS308 Switch SPHINX EDS308 Power Supply 230/48VDC 6Amp Power Supply 230/48VDC 6Amp Converter 48/24VDC Converter 48/24VDC Switch SPHINX EDS308 Switch SPHINX EDS308 Switch SPHINX EDS308 Switch SPHINX EDS308 ADAM 4520 ADAM 4520 ADAM 4520 ADAM 4520 DIRIS Ap Converter 48/24VDC Converter 48/24VDC Converter 48/24VDC Converter 48/24VDC Ethernet GPN Ethernet GPN Remote Reboot Remote Reboot DIRIS Ap RT RR 230VAC 48VDC ADAM 4520 ADAM 4520 ADAM408 0 & Pt100 ADAM408 0 & Pt100 ADAM408 0 & Pt100 ADAM408 0 & Pt100 ADAM408 0 & Pt100 ADAM408 0 & Pt100 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 Jbus/RS485 Win3200/RS232 870-5-104/TCP/IP Remote Desktop Connexion RR ELECDAN Counters ELECDAN Counters ELECDAN Counters ELECDAN Counters ELECDAN Counters ELECDAN Counters
6
EL SCADA Components Rad Tests Mechanical design –No extra shielding, Light rack mounting Statistics –3 systems in // –Permanent monitoring –Human daily check Costs –Components: 20kCHF –Work: 10kCHF Conditions –Activated material –Not repairable –Not re-usable Schedule –CNGS TSG46 –Time slot to be defined Rack Front viewRack Back view
7
EL SCADA Components Rad Tests