Presentation is loading. Please wait.

Presentation is loading. Please wait.

PROFIBUS "Ready for anything!".

Similar presentations


Presentation on theme: "PROFIBUS "Ready for anything!"."— Presentation transcript:

1 PROFIBUS "Ready for anything!"

2 OPC is Standard Programming Interface
Openness System-wide operation between automation products of different manufacturers Ease of Use Same user interface for different components Connectability Can be reached by any computer in the LAN/WAN (via COM/DCOM)

3 S7 Communication Optimized within the SIMATIC S7/M7/C7
DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2 Optimized within the SIMATIC S7/M7/C7 Network independent software interfaces for MPI, PROFIBUS and Industrial Ethernet Connection of PCs and workstations possible Useful data quantity per job up to 64 Kbytes

4 FMS Fieldbus Message Specification
Standardized protocol Layer 7 to ISO corresp. to EN50170 Communication between different automation systems from different manufacturers SIMATIC S5, SIMATIC S7, PC, Non-Siemens systems and field devices Availability of different communication services on level 7 DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2

5 S5-Compatible Communication (SEND/RECEIVE)
Communication via FDL Layer 2 to ISO corresp. to EN50170 For communication between different automation systems SIMATIC S5, SIMATIC S7, PC, non-Siemens systems Simple, safe transfer of unstructured data blocks DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2

6 PG/OP Communication Communication functions between
DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2 Communication functions between SIMATIC PG (STEP 7, STEP 5) or HMI devices (e.g. TD/OP) and the SIMATIC automation systems Supports MPI, PROFIBUS and Industrial Ethernet

7 DP and PA Distributed I/O
Standardized protocol Layer 2 to ISO corresp. to EN50170 Connection of distributed I/O to one master (PLC, PC) ET 200, field devices Fast, cyclic data exchange PROFIBUS PA (process automation) Expands PROFIBUS-DP by the intrinsically safe transmission technique according to the international IEC standard DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2

8 Functional Levels of PROFIBUS DPV0 ... DPV2)
Time Cyclic Data Exchange between Master and Slave Devices GSD Configuration Diagnosis extension: Acyclic Data Exchange between PC or PLC and Slave Devices Integration within Engineering: EDD and FDT Portable PLC Software Function Blocks (IEC ) Fail-Safe Communication (PROFIsafe) Data Exchange Broadcast (Publisher / Subscriber) Isochron Mode Clock Synchronization & Time Stamps Up/Download (Firmwareupdate) Redundancy PROFInet (Ethernet) Horizontal Integration Vertical Integration (MES) DP-V0 DP-V1 DP-V2

9 DPV1 Extensions to DP Standardized protocol
Layer 2 to ISO corresp. to EN50170 Acyclic communication to access Data Sets Master Class 1 Master Class 2 Alarm Handling DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2

10 DPV2 Extensions to DP Standardized protocol
Layer 2 to ISO corresp. to EN50170 Support of Motion-Control Applications Isochrone-Mode DXB (Data-Exchange-Broadcast) DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2

11 SIMATIC NET CP 5613 The fastest Profibus PC card of the world
DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2 The fastest Profibus PC card of the world Optimized functions for DP, DPV1 and DPV2 PROFIBUS solution for all communication protocols, also for multi protocol mode

12 PC based Control with PROFIBUS
CP 5613 PROFIBUS Slaves PROFIBUS-DP, PG/OP Comm. PG/PC/OP Einführung Bei WinAC Basis unterstützt die Kommunikation with anderen Automatisierungssystemen über die Profibus Schnittstelle. Nebst dem DP Protokoll ist die PG/OP- Funktionalität implementiert. Sowith lassen sich nicht nur DP-Slaves sondern auch aktive S7-Systeme wie OP und PG/PCs anschließen.

13 Visualization with PROFIBUS
CP 5613 S7 Communication PC with WinAC® Pro S7 PLCs

14 SIMATIC NET CP 5613 FO The fastest Profibus PC card of the world
DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2 The fastest Profibus PC card of the world Now also with optical interface for direct connection to the optical Profibus Same functionality as CP 5613

15 Integrated FO - Optical PROFIBUS on PG/PC
Soft Control ET 200B Master ET200 X with BM 143/DESINA ET 200S with IM 151 FO CP 5613 FO RS485 OBT S7-300 with CP FO ET 200M with IM FO further nodes PROFIBUS optical

16 SIMATIC NET CP 5614 The fastest Profibus PC card of the world
DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2 The fastest Profibus PC card of the world PROFIBUS-DP master and DP slave on one module

17 Application example: Robot control with PROFIBUS
PG/PC/OP Control system e.g. S7-400 Robot control CP 5614 SOFT NC Einführung Bei WinAC Basis unterstützt die Kommunikation with anderen Automatisierungssystemen über die Profibus Schnittstelle. Nebst dem DP Protokoll ist die PG/OP- Funktionalität implementiert. Sowith lassen sich nicht nur DP-Slaves sondern auch aktive S7-Systeme wie OP und PG/PCs anschließen. Robot IO

18 SIMATIC NET CP 5614 FO The fastest Profibus PC card of the world
DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2 The fastest Profibus PC card of the world Profibus DP master and DP slave on one board Assignment to optical or electrical interface freely selectable

19 Integrated FO - Optical PROFIBUS on PG/PC
SoftControl ET200 X with BM 143/DESINA ET 200S with IM151 FO ET 200M with IM FO S7-300 with CP FO CP 5614 FO Master PROFIBUS optical further nodes Slave ET 200M with IM 153 ET 200S with IM151 Master PG/PC with CP 5613 PROFIBUS electrical further nodes

20 CP 5613 / CP 5614 Development Kit DK-5613
For integration of CP and CP 5614 in all PC-based operating system environments Source code free Technical Support and service for incorporation in any operating system environment

21 SOFTNET for PROFIBUS SIMATIC NET Software
DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2 Low-cost protocol stacks for many PROFIBUS protocols Can be used with CP 5511, CP5512 and CP 5611 SIMATIC NET Software

22 SIMATIC NET CP 5511 Connection for notebooks and other portable PCs
DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2 Connection for notebooks and other portable PCs e.g. for diagnostics and commissioning

23 e.g. for diagnostics and commissioning
SIMATIC NET CP 5611 DP-M DP-S PG/OP S5-K FMS DPV1 S7-K DPV2 Connection for portable PCs e.g. for diagnostics and commissioning Simple installation and startup

24 Automation Made Easy! Totally Integrated Automation with SIMATIC NET


Download ppt "PROFIBUS "Ready for anything!"."

Similar presentations


Ads by Google