Download presentation
Presentation is loading. Please wait.
Published byAmos Wilkinson Modified over 9 years ago
2
www.sendig.com1 Typical Steps of field Balancing Illustration with model 907 E-mail: sales@sendig.com, sendigbj@yahoo.com.cn sales@sendig.comsendigbj@yahoo.com.cn Telephone: +8610 82895321 Fax: +8610 82895320 http://www.sendig.com Balancing Training Part 1
3
www.sendig.com2 1. Collecting Machine data 2. Preparing Instrument & Sensor 3. Balancing really required ? 4. Balancing possible ? 5. Procedure of balancing An Overview of the Steps
4
www.sendig.com3 Step 1 - Collecting Machine data Understand the machine to be balanced as much as possible Collect machine data Take a photo of the machine
5
Sample: Machine to be balanced Impeller Parameter: Diameter: 1400mm Thickness: 500mm Blade Number: 12 Material:Fiberglass-Reinforced Plastics RPM: 1825 r/min Bearing Model: ? Motor Parameter: Power: 75kW RPM: 1500 r/min Others: Belt transmission Spring base Manufacture: LG Impeller Bearing1 Bearing2 Motor
6
www.sendig.com5 Step 2 - Preparing Instrument & Sensors Sendig-904/907 dual-channel data collector/analyser/balancer A notebook computer Sendig-MCM3 Analysis Software
7
www.sendig.com6 Sensors & Cable connecting Attach reflecting paper on shaft
8
www.sendig.com7 Step 3 - Balancing really required ? Use 904/907 to measure overall vibration values Compare with ISO Standard 1) Switch to Analyzer 2) Use “ Collector ” to measure vibration
9
www.sendig.com8 6: Point: Motor-1-Side-2-X Alarm-mode: Displacement Freq-Range: 500Hz Sensor:4.6 ………………………… New Data Old Data ACCxxx / xxx m/s 2 VEL7.2 / 2.1 mm/s DISP68 / 12 µm ENV xx / xx m/s 2 Horizontal VELOCITY is the critical parameter
10
Comparison with ISO2372
11
www.sendig.com10 Overall Value Measurement Acc. Vel. Disp. Envelope Peak ms -2 RMS mm/s P_P um RMS ms -2 Hor. 88.81 9.95 101.5 5.268 Ver. 55.89 5.554 38.77 7.362 Sample
12
Measurement 9.95 mm/s Not Permissible, Balancing really required ! Sample
13
www.sendig.com12 Step 4-1: Balancing possible? – “ single peak spectrum ” ? Use 904/907 to measure vibration spectrum Only “single peak spectrum” can go for balancing 1) Switch to Analyzer 2) Use “ Collector ” to measure vibration 3) Use “ C-Spect ” to see velocity spectrum
14
www.sendig.com13 Sample of non-single peak spectrum- not suitable for Balancing
15
www.sendig.com14 Sample of non-single peak spectrum- Better change bearing before balancing
16
www.sendig.com15 Sample of single peak spectrum – You can reduce the vibration by Balancing
17
www.sendig.com16 Step 4-2: Balancing possible ? – “ 90 o phase difference ” ? Use 904/907 to measure vibration phase difference between vertical and horizontal directions Only “90 o phase difference” can go for balancing 1) switch to balancer and use 2-planes balancing procedure 2) Page down to “ Initial Measurement ” to measure vibration phase at X & Y 3) See if “ 90 o phase difference ” exist?
18
www.sendig.com17 Phase Measurement: Velocity Amplitude Phase Vertical: 9.416 320 Horizontal: 3.08 116 Since phase difference is not 90 o nor closer to 90 o, this means the problem with the fan is something else other than unbalance. Phase difference not 90 o Sample Sample of “non-90 o phase difference” – You cannot reduce the vibration by Balancing
19
www.sendig.com18 1. Phase stable 2. Phase Measurement: Velocity Amplitude Phase Vertical: 0.693 73 Horizontal: 1.569 150 ? Phase difference is 77 o Sample Sample of nearly “90 o phase difference” – You can reduce the vibration by Balancing
20
www.sendig.com19 Procedure of balancing Balancing Training Part 2
21
www.sendig.com20 Different Kinds Of Imbalance 1-plane imbalance 2-plane imbalance
22
www.sendig.com21 Characteristics Of Imbalance 1. The vibration frequency is mainly composed of RPM frequency. For each round the rotor turns, a vibration is occurred. 2. The wave is an approximate sine wave. 3. There is a difference of 90 o between the vertical vibration phase and the horizontal one. 4. With RPM increasing, the vibration amplitude is increased
23
www.sendig.com22 Basic Principle Of 1 Plane Balancing amplitude phase RPM A 1 select a plane to fix trial mass and a point to measure, draw scale of phase and sign of 0 o phase 2 measure initial vibration A 0 (phase and amplitude) 3 fix a trial mass Q on the plane, measure vibration A 1 4 calculate influence coefficients: 5 calculate balancing mass P:
24
www.sendig.com23 Illustration of 1 Plane Balancing A0A0 A1A1 A 1 - A 0 o draw A 0 & A 1, calculate A 1 - A 0 measure the angle between A 1 - A 0 and A 0 turn Q a along the direction of , gain the correct location of balancing mass. the weight of balancing mass is as the following : K o Q P
25
www.sendig.com24 Method of Influence Coefficients Method of influence coefficients is widely used, its step as the following (1 plane balancing as example): 1 measure initial vibration 2 fix a trial mass 3 measure the vibration with the trial mass 4 calculate the result of balancing mass
26
www.sendig.com25 IF THE INFLUENCE COEFFICIENTS ARE KNOWN, THE STEP OF FIXING TRIAL MASS ARE IGNORED The former steps are simplified as the following: 1) measure initial measurement 2) input influence coefficients 3) calculate the result of balancing mass
27
www.sendig.com26 NOTICES DURING THE OPERATION Confirm the dynamic balancing are needed according to spectrum and phase analysis. Direction of phase: reverse to the direction of rotation Reflecting slice phase
28
www.sendig.com27 SELECTING PARAMETERS Measure displacement or velocity for middle or low speed machines Measure velocity or acceleration for high speed machines
29
www.sendig.com28 CONFIRM whether the trial is suitable The radius of loading trial mass is as same as loading the amended mass The turning speed is steady
30
www.sendig.com29 1-PLANE BALANCING Without influence coefficients 907 A Tacho sensor Accelerometer
31
www.sendig.com30 Operation Basic Prompt is displayed at the last line Press ‘ ∧ ’ and ‘ ∨ ’ key to move the cursor up and down Press Enter to select iterm Press number keys to input digits To other MENU, press PgDn or PgUp
32
www.sendig.com31 Always make sure the “ Setting ” is correct before the balancing Enter a digit, select 1 set of data from 10 Enter a digit, select plan number Change by “ENTER”, use displacement or velocity for most machines Input sensitivity (from accelerometer certificate)
33
www.sendig.com32 INITIAL MEASUREMENT Press Enter to measure rotation speed first Press Enter for a moment to measure vibration after rotation speed become steady After phase and amplitude become steady, press Enter for a moment to end the measurement
34
www.sendig.com33 TRIAL ESTIMATION Input the 4 parameters When cursor on 6th line, press Enter to calculate trial range Stop the machine, fix a trial mass according to the range
35
www.sendig.com34 TRIAL MEASUREMENT Input phase and weight of the trial, confirm whether it will be removed afterward, restart the machine Move cursor to 6th line, press Enter to measure rotation speed When RPM steady, press Enter a moment to measure vibration When amplitude and phase steady, press Enter for a moment to end the measurement
36
www.sendig.com35 TRIAL RESULT See what the 6 th line shows If YES displayed, press Pg Dn to go on If NO displayed, stop the machine, adjust trial mass, return to the early page of TRAIL MEASUREMENT, measure again
37
www.sendig.com36 CALCULATION Cursor on 2 nd line, press ENTER to calculate influence coefficients The result is shown in 4 th line Cursor on 2nd line, press Enter to calculate balancing mass The result is shown in 3 rd line
38
www.sendig.com37 Decomposing/Splitting Input the 2 angles Display the results If nothing displayed at right side, change the order of the 2 angles and re-enter Pa Pa1 Pa2
39
www.sendig.com38 VERIFICATION Cursor on 2nd line, press Enter to measure rotation speed When RPM steady, press Enter a moment to measure vibration When amplitude and phase steady, press Enter for a moment to end the measurement The last 2 lines displays the results
40
www.sendig.com39 1-PLANE BALANCING With influence coefficients, you do not need to add trial mass. You need only measure the initial vibration
41
www.sendig.com40 SETTING PARAMETERS Set “Yes” for the question of “Have influence Coefficient?”
42
www.sendig.com41 INITIAL MEASUREMENT Press Enter to measure rotation speed Press Enter for a moment to measure vibration after rotation speed become steady When phase and amplitude become steady, press Enter for a moment to end the measurement
43
www.sendig.com42 INPUT COEFFICIENTS Move the cursor to the 4th line, input amplitude and angle of coefficient Press Pg Dn to the next page
44
www.sendig.com43 Calculation, Decomposition & verification calculate balancing mass Decomposition and verification are the same as illustrated earlier Pa Pa1 Pa2
45
www.sendig.com44 2-PLANES BALANCING Without influence coefficients The main difference than 1-plane: 1. Need to add trial mass one after another at the 1 st plane and 2 nd plane 2. Need to use 2 vibration sensors
46
www.sendig.com45 Sensors & Cable connecting Attach reflecting paper on shaft
47
www.sendig.com46 SETTING PARAMETERS
48
www.sendig.com47 INITIAL MEASUREMENT & TRIAL ESTIMATION Get 2 lines of reading here
49
www.sendig.com48 TRIAL I MEASUREMENT Input phase and weight of the trial on plane 1, decide if it will be removed, restart the machine
50
www.sendig.com49 TRIAL II MEASUREMENT Input phase and weight of the trial on plane 2, decide if it will be removed, restart the machine
51
www.sendig.com50 Calculation, Decomposition & Verification calculate balancing mass Decomposition and verification are the same as illustrated earlier Pa Pa1 Pa2 Pb Pb1 Pb2
52
www.sendig.com51 2-PLANES BALANCING With influence coefficients With influence coefficients, you do not need to add trial mass. You need only measure the initial vibration.
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.