 Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Similar presentations


Presentation on theme: " Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain."— Presentation transcript:

1

2  Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain Kitchen Hood System Standpipe Pre Action & VESDA Systems

3 NORTH Ambulance EntranceMain Entrance Sprinkler Riser Room Fire Dept. ConnectionKnox BoxEnunciator Panel Standpipe Roof Acess

4 Located on Jensen St. Side Of Hospital You will need the knox key to remove the caps on the FDC

5 To access Key use door code followed by #

6 FACP located on floor one in boiler room. Annunciator panels located on all floors. Printer located near FACP prints all activity associated with fire systems

7 BRAIN (Fire Pump Control Panel) HEART (FIRE PUMP) CPR Blood Vessels (Piping) Nervous System

8 Water In Pump Bypass Always Open Fire Pump Jockey Pump Test Header Always Closed Back To Riser Double Check Valve Floor 1 Riser/Standpipe Floor 2,3 & Roof Riser/Standpipe

9 Isolation Valve Will Turn off water to floors 2 & 3 Isolation Valve Isolates 2 nd floor Sprinklers Flow Switch Floor 2 2 ½ Inch Connection

10 2 ½ “ Connection Both Are Supplied From Sprinkler System

11 Roof Access South Stairwell Roof Standpipe PIV Dry Beyond Valve Ceiling of south Stairwell Roof Standpipe

12 Kitchen Hood Flow Switch Is Tied Into The Fire Alarm System

13

14 Located outside every elevator door. Curtains are activated with fire alarm or sprinkler water flow

15

16 Located near stairway/ atrium on floor one. Activated with fire alarm or water flow. In place to prevent smoke migration between floors.

17

18 Generator Located Here

19 Underground tank contains approximately 3,000 gallons of diesel fuel.

20

21 Pre Action Located In ClosetFloor 2 VESDA Located On Floor 1 in MRI Area Loss Of Air Pressure Plus Activation Of Smoke Detector Required For Water To Enter The Sprinkler Piping Air Compressor Solenoid Holds Water Back VESDA Similar To Pre Action. Goes Into Pre Alarm Notifying Staff Well In Advance Of Actual Fire.

22