Download presentation
Presentation is loading. Please wait.
Published byMyrtle McDowell Modified over 9 years ago
1
Confidential Document 1 EverAccess Product Overview By Julian Garcia
2
Confidential Document 2 Introduction Flex Series Controller The basic model supports 2 readers (doors). Expandable to 127 controllers (8 readers each) = can support up to 1016 readers per application. Flexibility to use different model readers in same application. Integrated keypad and LCD Real Time Data Transfer APB Capabilities Retains 16,000 events in controller (exportable to MS Excel for archiving.) Streamlined design, attractive appearance
3
Confidential Document 3 Controller Specs Maximum Cards (Users) Supported: 9,999 Cluster Configuration: Up to 32 Comm. Data Format: Bit Wiegand or RS232 Alarm Input: 1 fire alarm input 1 tamper input Alarm Output: 8 relay outputs, expanded to 16 Communication Port (to PC): RS232/RS485 Programmable Time: 10 intervals per day Programmable Dates: 10 kinds Groups: 256 APB:Yes Keypad: 4 x 4 Display: 2 x 16 LCD Real-Time Clock: Yes Buzzer: Built-in Power: DC 12V + 15% Backup Power connection: Yes Dimensions: 11.7” x 8.4” x 1.3” (30 x 21.6 x 3.3 cm) Power Consumption: Maximum 30 W
4
Confidential Document 4 Reader Specs Frequency: 125 KHz Data Format: 64 bit Read Range: 5cm-10cm (2-4”) Read Time: 200ms Output Format: Bit Wiegand or RS232 format to EverAccess controller Audio: Built-in Buzzer 2KHz Indicator: 3 LEDs Power Supply: 6.5 V~18 VDC, Max 150 mA Operating Temperature: -10°C ~ +60°C (14°F ~ 140°F) Dimensions: 4.8” x 3” x 0.8” (12.3 x 7.7 x 2.1 cm) Tamper Switch: Standard ERK-871 ERM -871 ERR-871
5
Confidential Document 5 System Reader (Card Enroller) ERS - 871 Connects to PC via USB and Controller via RS485 Frequency: 125 KHz Data Format: 64 bit Read Range: 5cm-10cm Read Time: 200ms Indicator: 4 LEDs Power Supply: 6.5 V~18 VDC, Max 150 mA Operating Temperature: -10°C ~ +60°C (14°F ~ 140°F) Dimensions: 3” x 4.5” x 1.1” (7.6 x 11.6 x 2.9 cm) Tamper Switch: N/A Interface: PC Interface USB or RS485
6
Confidential Document 6 Biometric Reader EBC - 890 Connects to PC via RS232 Fingerprint Verification Time: <3 Sec. Event Record Capacity: 40,000 Communication Format: 26 or 34 Bit Weigand Alarm inputs: 1 Fire, 4 Zones Power Supply: 10V~15 VDC Built In Keypad: 4”X4” Backlit Dimensions: 7” x 5.4” x 2.9” Power Consumption: >9W Max Current Draw: Door Control Relay: 5A Alarm Relay: 2A
7
Confidential Document 7 FlexPack Parts (EFLP-02-1A) One 2 Door Controller Two Mullion Readers One System Reader Flex Series Software Lock Box Enclosure Power Supply 24 Thick Proximity Cards ECD-50: 50’ Cable
8
Confidential Document 8 System Configurations: 1 of 3 RS232: Simple 1-to1 Direct Connection The Controller can be connected directly to the PC via serial port RS232
9
Confidential Document 9 System Configurations:2 of 3 RS485 Bus System: Multiple controllers in series. Multiple EverAccess controllers can be connected to accommodate larger access control systems. The controllers are connected via RS485. The System Reader is a critical component of an RS485 bus based system: it allows simple card enrollment and acts as the interface between multiple controllers and the PC. RS485
10
Confidential Document 10 System Configurations: 3 of 3 TCP/IP Based Network System The controller can be networked via TCP/IP in order to remotely manage the controller over internet or intranet. The EverAccess LAN adaptor (part number EA-LAN1) is required to convert RS232 /RS485 signals to TCP/IP Maximum: 127 Controllers per system TCP/IP WAN/LAN TCP/IP EA-LAN1 Converter Controller 1 Controller 2 RS486
11
Confidential Document 11 Controller Operations Operations can be performed at the Controller using the keypad and LCD. There are 10 Setting Menus: 1. System Setting 2. Card Setting 3. Reader Setting 4. Door Setting 5. Alarm Setting 6. Alarm Action Setting 7. Extended Alarm Setting 8. Alarm Time Setting 9. Armzone Setting 10. Address Setting
12
Confidential Document 12 Controller Operations 1. System Setting: In the System Setting Menu, the user can set basic functions: System date and date Format Auto Daylight savings time Time System Pin System Arm Pin Erase all events Reset all data and setting Passwords
13
Confidential Document 13 Controller Operations 2. Card Setting: In the Card Setting Menu, the user can set basic functions: Add cards Delete Card or delete all cards Set cards priorities, including: Card status setting (enable/disable card) Access right setting Group setting Set card pin setting Anti Passback (APB) setting Card Arm Setting (enable/disable arm/disarm function) Show card number
14
Confidential Document 14 Controller Operations 3. Reader Setting: In the Reader Setting Menu, the user can set basic functions: Keypad setting Reader to door allocation System reader setting
15
Confidential Document 15 Controller Operations 4. Door Setting: In the Door Setting Menu, the user can set basic functions, such as: Door setting Open time setting Set door hold open time Set door behavior at fire time
16
Confidential Document 16 Controller Operations 5. Alarm Setting: In the Alarm Setting Menu, there are three main sub-menus: - Alarm Action Setting Menu: Configures alarm outputs of all events on the main module and the door module. - Extended Alarm Setting Menu: Configures alarm outputs of all events on alarm module. - Alarm Time Setting Menu: Configures the time period of alarm outputs.
17
Confidential Document 17 Controller Operations 6. Alarm Action Setting: - In the Alarm Setting Sub-Menu, alarm output configuration for all events is basically the same, for example: - The upper line indicates the card to be configured is an invalid card. - The first 8 characters of the lower line are alarm output status of this event on the door module. - The 2 characters following the minus sign are alarm output status on the Main alarm output and Auxiliary alarm output on the main module. - Y indicates there is alarm output (relay energized). - N indicates there is no alarm output (relay not energized). - R refers specifically to alarm output relay on the corresponding door module.
18
Confidential Document 18 Controller Operations 7. Extended Alarm Setting: - In the Extended Alarm Setting Sub-Menu, the user can set basic functions, such as: - Fire Alarm - Zone Alarm 1~8 - System, ARM and card PIN failure - ARM IN 0 - Remote Alarm - Unknown, expired and invalid card - Invalid door and time - Card anti-passback failure - Door forced or held open - Reader lost
19
Confidential Document 19 Controller Operations 8. Alarm Time Setting: - In the Alarm Time Setting Sub-Menu, the user can reset the alarm or set a certain period of time an alarm output remains active. - Use numeric keys to enter the desired alarm time. - Enter minutes as a 3-digit number 0~999 and seconds as a 2-digit number 0~59. - The default value of alarm time is 1 minute.
20
Confidential Document 20 Controller Operations 9. Armzone Setting: - In the Armzone Setting Menu, the user can set basic functions, such as: - Set active Armzone - Set Arm delay time - ARM delay time: When an arm operation is executed, all active arm zones will enter ARM enabled status only after a certain time delay. - Use numeric keys to enter the desired ARM delay time. - Enter minutes as a 3-digit number 0~999 and seconds as a 2-digit number 0~59.
21
Confidential Document 21 Controller Operations 10. Address Setting: - Each device connected to the same RS485 bus must have a unique address for the purpose of communications and control. When multiple controllers connect to PC via an RS485 bus, each controller must be assigned a distinct address. - In the Address Setting Menu, the user can set this address setting - Use numeric keys to enter desired address in the range 0000~9999.
22
Confidential Document 22 Summary Key Selling Points: - Register ANY size project with EverFocus and receive: - System design assistance. - Discount through distribution. - Post installation support. - Simple installations. - Expandable topology.
23
Confidential Document 23 Contact Information Julian Garcia Office: 626-844-8888 Ext 107 Fax: 626-844-8833 E-mail: julian.garcia@everfocus.comjulian.garcia@everfocus.com Mobile: 626.826.8363 Rodney Guinto Sr. Sales Engineer E-mail: rodney.guinto@everfocus.comrodney.guinto@everfocus.com Office: 626.844.8888 Ext 127 Mobile: 818.216.6513 Link to download manuals: ftp://208.50.31.200/Product%20Manuals/Access%20Control/ftp://208.50.31.200/Product%20Manuals/Access%20Control/
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.