SF-3000 Installation Manual. 2 Back of SF-3000 3 CON400) USB connector - User can use USB memory stick after connect USB connector of key PCB. CON500)

Similar presentations


Presentation on theme: "SF-3000 Installation Manual. 2 Back of SF-3000 3 CON400) USB connector - User can use USB memory stick after connect USB connector of key PCB. CON500)"— Presentation transcript:

1 SF-3000 Installation Manual

2 2 Back of SF-3000

3 3 CON400) USB connector - User can use USB memory stick after connect USB connector of key PCB. CON500) LCD Connector - It is connected with LCD cable in front cover CON503) Finger-Module Connector - It is connected with fingerprint module in front cover. CON505) LED Connector - It is connected with 3 LEDs placed in the upper right of front cover. CON504) Cardreader Connector - When user needs to use RF card reader, can be connected with necessary PCB in this area. (In this case, only 1 external card reader can be possibly installed) CON506) KEY Connector - It is connected with KEY PCB in front cover CON501) Speaker Connector - It is connected with speaker in front cover Some important factors prior to connection (Internal)

4 4 Some important factors prior to connection (External) VR500) LCD Switch - It controls the brightness of LCD screen. CN501) Relay 1, 2 - It is connected with doorlock and alarm devices VR501) Speaker volume switch - Controls speaker volume. CN506) Wiegand output - Outputs user ID as Wiegand data. (It is used is used when SF-3000 needs to be connected with other main controller) CN505) Sensor - Connects various sensors (door contact, alarm sensor, etc) and Out button CN502) Relay 3,4 - Same as Relay 1, 2 as above (Reserve purpose) CN503) Card connector - Can be connected with external card reader CN700) Power Input - It sends 12V power received by power supply to SF-3000 LAN_RJ45) TCP/IP Connector - It is used for connection of TCP/IP RJ45 JACK. CN500) Serial Port - 232, 485 communication Port

5 5 - This figure shows the connection from PC to controller via RS-232. - Maximum distance using the RS-232 is 15m. Some important factors prior to connection (RS-232)

6 6 As drawing in left, It is possible to connect several additional SF-3000 with cable which connects SF-3000 and computer But the Max. no of SF-3000 which can be connected with 1 direct port is 16 Some important factors prior to connection (RS-485) The Max. no of SF-3000 connection per each port is 16 ’ At that time, address should be serup per each product. Please refer to user manual how to setup address. If address is not setup, communication doesn ’ t work due to communication collision.

7 7 1) As drawing in left, If main computer controls more than 16 SF-3000 ’ s, the No. of port should be more than one 2) Number of ports needed for SF-3000 SF-3000 (pcs.)Port (No) 161 322 483 644 Some important factors prior to connection (RS-485 Max. connection)

8 8 Some important factors prior to connection (LAN) - The drawing above shows the LAN composition that connects the SF-3000 using the TCP/IP converter. - Maximum of 64 units can be connected using the TCP/IP communication. Please refer to the program manual or the user manual for further instructions for the setup.

9 9 Some important factors prior to connection (WAN) -The drawing shows the connection of LV-5000(Max. of 64) using WAN - Each LV-5000 should have its own IP address and maximum of 64 IP is needed.

10 10 Guide for cable connection (Power 1) - CN700 is on the backside of PCB, and connect DC12V power into Power supply. - The direction of the GND and VCC does not matter. CN700 power connector

11 11 Guide for cable connection(RS-232, RS-485) - Needs to connect RS-232 connection of PC with No. 1, 2, 5 PIN of CN500 connector - Needs to connect RS-485 connection of 485 connection converter with No. 3 & 4 PIN of CN500 connector. 1 2 3 4 5 pin No. 1 PIN : RS232 Rx No. 2 PIN : RS232 Tx No. 3 PIN : RS485 B No. 4 PIN : RS485 A No. 5 PIN : GND CN500

12 12 Guide for cable connection(TCP/IP) - In case of TCP/IP connection, there is no distance limit and it can be used for LAN as well as WAN. - The drawing shows the TCP/IP connection with LV-5000 using the HUB. - For instructions for set up please refer to the program manual. LAN_RJ45

13 13 Guide for cable connection (WIEGAND OUT) -If LV-5000 is connected to another main controller, it plays a role as a card & fingerprint reader only. -At this moment, if it needs to relay the information stored in SF-3000 to main controller, it needs to use ‘ Wiegand Out ’ (CN506). - For cable connection, it needs to connect CN506 of SF-3000 with card reader connection of main controller 1 2 3 4 5 pin No. 1 PIN : DC 12V No. 2 PIN : GND No. 3 PIN : Wiegand DATA0 OUTPUT No. 4 PIN : Wiegand DATA1 OUTPUT No. 5 PIN : GND CN506

14 14 Guide for cable connection (RF card reader) - If LV-5000 is connected with a RF Card Reader, it needs to be connected to the J10 - The drawing above shows the connection with K10/20. - Cable connection may be different from each product and user needs to check the manual for each device. CN503

15 15 Guide for cable connection (sensor 1) - Besides reader, SF-3000 can controls with connection of many sensors. - This shows that the connection of door contact (detector of door open/close) and out button. - Connect the cable coming out of door contact and out button to J12 like the above. CN505

16 16 Guide for cable connection (sensor 2) - The drawing shows the LV-5000 controlling the sliding auto-door and its related devices. - The cable coming from the door contact, door sensor, out button, and IR sensor needs to be connected like the drawing above. CN505

17 17 Guide for cable connection (relay ½ ) - LV-5000 physically controls access by connecting many devices which can detect certain situations by using various sensors installed in the front. - Electric Strike or alarm devices can be operated with LV-5000 using the connection of CN4. 1 2 3 4 5 6 pin No.1 PIN : N.O No. 2 PIN : N.C No. 3 PIN : COM No. 4 PIN : N.O No. 5 PIN : N.C No. 6 PIN : COM CN501 RELAY1/2 RELAY1 RELAY2

18 18 Guide for cable connection (relay 3/4) -The RELAY3/4 of CN502 is for the purpose of reserve and it can be used when Relay ½ does not work properly or it can be used as a additional Relay. 1 2 3 4 5 6 pin 1 번 PIN : N.O 2 번 PIN : N.C 3 번 PIN : COM 4 번 PIN : N.O 5 번 PIN : N.C 6 번 PIN : COM CN502 RELAY3/4 RELAY3 RELAY4