Download presentation
Presentation is loading. Please wait.
Published byVictoria Bruce Modified over 9 years ago
1
ASI Controls HVAC Control Building Automation Energy Management Since 1986 HVAC Control Building Automation Energy Management Since 1986 ASI Controls Reliability · Performance · Value
2
Digital Control Products Telecommunication Commercial Industrial Educational Institutional Governmental
3
Application Flexibility HVAC and Lighting Facility Automation Refrigeration/Cold Storage Remote Monitoring Energy Management and Cost Control
4
Reliable Hardware ASIC/2 configurable controllers for power, flexibility, scalability ASIC/1 pre-programmed controllers for terminal unit applications JASIC Open Systems controllers, running Niagara AX Framework
5
Intuitive Software PC-based web front ends Automated alarm notification Database ODBC R/W capability Graphical configuration Optional embedded front end and configuration software
6
Open Systems Interfaces JASIC Open Systems use Niagara AX Framework to integrate LON and other legacy BAS protocols
7
JASIC Open Systems, powered by Niagara AX, with drivers for BACnet, LON, Modbus, etc. WebLink OPC-client front end with ODBC R/W ASIC/2 controllers with Modbus RTU Master BACnet-IP system and BACnet MS/TP controller interfaces Interoperability Options
8
System Architectures Choice of Niagara AX or ASI Controls based system architectures Scalable open systems Range of choices for cost-effective Ethernet connectivity
9
Packaged Units Equipment Shelters ASI in Control – Small …
10
Medium … Hotel, Retail Network, Factory, Office Building …
11
Multi-zone & networked buildings Integrated control of large facilities BOMA Large Building of the Year, 1994 … Large
12
ASIC/2-7540 Configurable 16 universal inputs (multiplex to 64) 8 analog + 12 binary outs RS-485 (2), RS-232, USB Modbus RTU Master Real time clock, onboard configuration storage
13
ASIC/2-8540 Configurable Real time clock Automated dial out RS-485 ports, RS-232, Modbus RTU Master 8 universal inputs (multiplex to 32); 4 analog + 8 binary outputs
14
ASIC/2-8540-BAC All the features of ASIC/2-8540 plus a BACnet MS/TP bus Second RS-232 bus supports either ASI or Modbus communication
15
Rooftop Package Control ASIC/1-8655 Flash memory 8 relay outputs, 2 analog outputs Modulating economizer Ready to control packaged rooftop units and heat pumps
16
VAV Control Integrated actuator Airflow sensor Screw terminals 5 analog + airflow inputs; 3 binary + 1 analog, 2 floating damper outputs ASIC/1-6000
17
BACnet VAV Control Integrated actuator Airflow sensor Screw terminals 5 analog + airflow inputs 3 binary + 1 analog, 2 floating damper outputs ASIC/1-6100
18
VAV Control -PD option for pressure- dependent applications -MB models with metal base, no actuator (for retrofit applications) ASIC/1-6000-MB, -PD, -PD-MB
19
Dual Duct & Exhaust Tracking Ready for common dual duct applications 2 calibrated airflow sensors included Exhaust tracking for positive or negative pressure ASIC/1-8800
20
Network Communication Ethernet-to-serial router, either RS-232 or RS-485 SNTP supports timekeeping & synchronization functions Intelligent forwarding of alarms & events Web server for configuration
21
JASIC-700 Controller RS-232, RS-485, 2 USB, 2 Gigabit Ethernet Embedded Web Front End with 3D HVAC graphics Optional drivers to tie into most common protocols Real-time clock, with battery or external power backup
22
JASIC-600 Controller RS-232, RS-485, 2xEthernet, USB port Embedded web front end with library of HVAC graphics, and optional configuration tools Drivers for many protocols Onboard clock, battery backup
23
JASIC-200 Controller RS-232, RS-485, 2xEthernet, USB port Embedded web front end with library of HVAC graphics, and optional configuration tools Drivers for many protocols Onboard clock, battery backup
24
JASIC Web Supervisor Server-based front end software Archives trend data, delivers automated alarm notifications Small, Large, or 64-bit version Database drivers available for MySQL, MS-SQL Server, Oracle, oBIX, SNMP, CSV/Excel....
25
JASIC Workbench Runs embedded or from networked computer Intuitive drag/drop interface Standard library of animated 3D HVAC component images Optional libraries to create custom AHU, RTU, Plant... System Configuration Software
26
Color Touchscreen HMI’s Interfaces to ASIC/2 controllers Support for JPG, BMP, GIF image formats 3.5”, 5.7” @480x320; 8”, 10.4”, 12.1” @800x600
27
Modbus-RTU Slave Identical color, size, and form as WS-051 sensor 4 digit LCD display Push-button mode and setpoint adjustment, afterhours overrides Modbus Wall Sensor
28
Temperature Sensors Digital display panel Setpoint adjust After-hours over-ride Display and controller read same sensor WS-051 WS-041 Built-in thermostat Setpoint adjust Sensor only, + push button, + user adjust, + PB & UA WS-001 WS-011 WS-021 WS-031 Outside Air, Duct Insertion, Averaging, Strap-on, and Immersion
29
Pressure, RH Sensors ranges Differential Pressure Transmitters in multiple ranges Relative Humidity, RH+Temp sensors Bulk polymer resistance for accuracy Room, Duct, and Outside Air options
30
Polling, Broadcasting & Event Notification Dual RS-232 access for PC, Modem, LAN Dual local buses RS-232 to RS-485 converter Network & System Interface
31
ASI-C/R Converter/Repeater RS-232 to RS-485 Converter RS-485 Repeater Plug and Play
32
Graphical, drag & drop configuration without line programming Real-time data display Password protection Re-use sequences between projects Sample configuration screen ASI Visual Expert
33
ASI WebLink Web browser based system front ends Customizable screen graphics, audio, video Drag and drop screen editor, OPC tag browser OPC for interoperability
34
SupportsSSL/HTTPS ASI WebLink
35
Report and Graph trends Export CSV data Customize access by user login and role Javascript customization ODBC Read/Write ASI WebLink
36
Manage networked facilities over LAN, WAN or WWW Integrate other BAS web servers for a unified Intelligent Building interface ASI WebLink
37
Automated delivery of email and/or text Alarm & Event notifications to individual or group Web interface for processing, managing alarm notifications ASI WebLink
38
Monitor and control remote facilities via Ethernet network Update network or sub-network with a single command ASI WebLink
39
ASI Atlas Map ASI points into BACnet UI through BACnet-IP interface ASI templates for common applications and configurations Users can create re-usable templates
40
191 Peachtree Tower, Atlanta Long-term support for back compatibility 1.2M square feet 1,500 ASIC/1 VAV’s with Fan Speed Control, Trane central Plant controls Upgrade facility awarded BOMA Large Building of the Year, 1998
41
Chartwell School, Seaside, CA USGBC LEED-NC 2.1 Platinum rated Net-zero electricity use with onsite solar panels Provide control of HVAC Total energy use is half of comparable buildings
42
Nankang Software Park, Taipei Over 5,000 ASIC/2 & ASIC/1 controllers 70,000+ total points Finalist ICF Intelligent Building of the Year, 2005
43
Other Notable Projects Other Notable Projects 3,000+ telecommunications buildings Hilton hotels in Anaheim, Chicago, New York, San Francisco and other flagship locations McChord AFB, WA – 45 networked buildings West Virginia DEP, LEED-NC Silver rated Hospitals, Retail Networks, Schools, College Campuses, Shopping Malls, Clean Rooms…
44
Our Goals Supply reliable, innovative and cost-effective control system hardware and software Provide VARs with tools for complete Energy Management, Building Automation & other control solutions Comprehensive training and customer support Reliability · Performance · Value
45
Contacts Authorized Reseller Authorized Reseller AkBin - Akıllı Bina Sistemleri ve Analizi Beyoğlu, İstanbul Tel: 554 646 8953 / 533 275 0338 Alper@akbin.com Headquarters Headquarters 2202 Camino Ramon San Ramon, CA 94583 Tel: 925-866-8808 info@asicontrols.com
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.