Presentation is loading. Please wait.

Presentation is loading. Please wait.

Rock Springs 2014 Problem Map Loose roof Supportable Loose Roof Supportable Rock Burst B Caved Air Tight Floor Bleeder Fire LHD LHD on Fire 3 Miners, One.

Similar presentations


Presentation on theme: "Rock Springs 2014 Problem Map Loose roof Supportable Loose Roof Supportable Rock Burst B Caved Air Tight Floor Bleeder Fire LHD LHD on Fire 3 Miners, One."— Presentation transcript:

1 Rock Springs 2014 Problem Map Loose roof Supportable Loose Roof Supportable Rock Burst B Caved Air Tight Floor Bleeder Fire LHD LHD on Fire 3 Miners, One dead one broken back, one unable to walk Miner Dead Caved Air Tight D C FAB Door is open D C B A 432 1 Water Knee Deep Haul Truck Haul Truck turned over Miner unconscious 12 Timbers4 Sets of Brattice Loose Rib Un-scalable Loose Roof Un-scalable Loose Rib Un-scalable LHD Haul Truck

2 Rock Springs 2014 Gas Map Loose roof Supportable Loose Roof Supportable Rock Burst B Caved Air Tight Floor Bleeder Fire LHD LHD on Fire Caved Air Tight D C FAB Door is open D C B A 432 1 Water Knee Deep Haul Truck 12 Timbers4 Sets of Brattice 19.7% O2 1200 ppm CO 0 % CH4 Heavy Smoke Light Smoke 20 % O2 800 ppm CO 0% CH4 Clear Air 20.9% O2 0.02 ppm CO 0% CH4 LHD Loose Rib Un-scalable Haul Truck

3 Rock Springs 2014 Solution Map Loose roof Supportable Loose Roof Supportable Rock Burst B Caved Air Tight Floor Bleeder Fire LHD LHD on Fire 3 Miners, One dead one broken back, one unable to walk Miner Dead Caved Air Tight D C FAB D C B A 432 1 Water Knee Deep Haul Truck Haul Truck turned over Miner unconscious 12 Timbers4 Sets of Brattice Loose Rib Un-scalable Loose Roof Un-scalable Loose Rib Un-scalable LHD Haul Truck Both fires will need to be put out. Two fire extinguishers will not do it and they will need to ask for fire fighting equipment. Mine will have a Foam machine. Only 4 sets of Brattice for ventilation, so this is why the fires will need to be put out. Close Door and build three stoppings. Air Lock Curtain will need to be changed to a stopping

4 Rock Springs 2014 Construction Map B D C FAB Door is open D C B A 432 1 20’x20’ 10’ 5’ 10’ 5’ 10’ 5’ 10’x10’or 10’x5’ 10’ 5’ S Ribbon 2’ 2’ x 1 0’ 10’x20’ 10’x10’ 130’ 100’

5 B D C FAB Door is open D C B A 432 1 Rock Springs 2014 Placard Map 88 8 8 8 8 8 8 1 1 2 3 4 5 5 5 5 6 6 7 7 7 7 9 9 9 9 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 11 9

6 Rock Springs 2014 Judge’s Map D C S

7 Rock Springs 2014 Team Map D C S

8 Placard Master (Per Field) 1.Door (Left Open)2 2.Brattice4 Sets 3.Timbers12 4.FAB1 5.Loose Rib Un-scalable4 6.Loose Back Un-scalable2 7.Loose Back 4 8.GasO2-20.9%8Back side of 5 O2-20.9% CO-0.02ppm CH4- 0% CH4-0.8% NO2- 1ppm NO2-1ppm 9. Gas O2-19.7%5Back sideClear Air CO-1200ppm CH4- 0% NO2- 2ppm 10. Gas O2-20.0%4Back SideClear Air CO-800ppm CH4- 0% NO2- 1ppm 11.Heavy Smoke5Back Side Clear Air 12.Light Smoke4Back Side Clear Air 13.Haul Truck2 14.LHD2 15.Caved Air Tight6 16.Permanent Stopping2 17.Barricade1 18.Rock Burst/Bad Ground1 19.Fire/LHD1Back sideFire Out 20.Floor Bleeder/Fire1Back sideFire Out 21.Water Knee Deep1 22.Curtain2Back SideStopping 23. #1115 Skip Mylou (dead)1

9 Solution We will assume that the team has shored up all areas in need. If the Team finds the miner alive in Drift D first, they will need to get him out as soon as possible. If they encounter the fire first, they need to put it out with the foam machine or if they decide to regulate it and then find the miner alive while going to the other side with undo delay, they will need to take the miner out first before addressing the other side of the fire. If the team finds the LHD fire they will need to put it out with the foam machine, as fire extinguishers won’t put it out. If they elect to regulate the fire they won’t have enough material to ventilate the mine. Once the team has accessed all possible areas of the mine, put out the two fires with the foam machine, brought out the live miner, they can proceed to make ventilation changes. 1.Build a stopping between entry 1 and 2 in the Main Drift. 2.Close the door between entry 1 and 2 in Drift A. 3.Build a stopping in entry 2 between Drift B and C. 4.Build a stopping in entry 3 between Drift B and C. 5.The fans can now be turned on. 6. A wing curtain will need to be held up to sweep the air in the chevron. 7.A temporary stopping will be built to Air Lock into chevron pillar between entry 3 and 4, in Drift C, as all the miners are unconscious and can’t talk. 8. The unconscious miner can be aroused and walked out. The other two miners must be taken out on a stretcher.

10 Rock Springs Mine Rescue 2014 Problem The Pepper Mine is a small underground salt mine that has 10 miners working here but only six miners work the underground. The mine is a single level operation and is accessed via a 15 percent decline. All of the mining equipment is mechanized. We only work one shift a day 7:00 AM to 4:00 PM five days a week. The ventilation is supplied to the mine by a fan located just outside the portal. Currently the fan is off because of an electrical problem but when operating generates 75,000 CFM. The air exhausts via a borehole/secondary escapeway which is located off the main drift just west of entry 1. At 9:30 am, Eddie Apple, our shifter, called out on his radio and said that he heard a loud pop and smelled smoke. That was all we got. When we tried to raise him and the other miners no one answered the radio. None of us are trained to go underground and we need you to go underground get our guys out and recover our mine. The Apple Dumpling Team has set up a Fresh Air Base in the Main Drift.

11 Rock Springs, WY 2014 Material List: 1.400 posts 2.108 (Weight such as sand bags, washers, 4x4 rock bolt bearing plates, etc.) 3.8000 feet of baler twine (heavy string) 4.4 colors of surveyors tape (3 rolls each) 5.5 rolls of duct tape 6.3 5 ft. hoses 7.24 Sets of temporary stopping/brattice material (stands &plastic fencing in 10 ft. lengths) 8. 3 Tables, (1 per field) 9.12 Chairs (4 per field) 10.3 Foam blocks 11.15 2’x2’x4’ Cardboard Boxes 12.3 Hand trucks 13.9 Patients (3 Victims per field) 14.3 5 gallon Buckets 15.1 Roll of black plastic if any is left from two years ago, this would work. First Aid, done by Mutual Aid Tec. Not sure of the BG4, Bio Marine units and Gas.


Download ppt "Rock Springs 2014 Problem Map Loose roof Supportable Loose Roof Supportable Rock Burst B Caved Air Tight Floor Bleeder Fire LHD LHD on Fire 3 Miners, One."

Similar presentations


Ads by Google