High Throughput And High Content Screening
2
What Is HTS ? Biochemical target Test many compounds Compounds with desired effect on target = Hit OR Hit directly used as chemical probe to study target Hit provides structure for chemists to begin developing a drug or other product
3
HTS Technology Robotics Miniaturization Sophisticated Assay Chemistry Sophisticated Software and Database
5
Evotec uHTS System Opera High Content Detector Plate:vision detector for fluorescence (also fluorescence polarization & fluorescence resonance energy transfer), luminescence, absorbance 2 CO 2 incubators 4 low volume pipetting systems for 384- and 96-well plates (multidrops, Cy-Bi well, Cy-By drop) Plate washer Centrifuge Piercer Plate storage, barcode readers, lid handlers, transport systems
6
plate::vision detector CCD camara Xenon lamp light source Zeiss optics Built in algorithm to correct for spherical lens aberration 4 filter sets –Excitation filter –Emission filter –Dichroic filter
7
Opera 4 lasers 1 xenon lamp 4 CCD cameras 96- and 384-well plates Acapella image analysis software
8
Software Systems Genedata Assay Analyzer Condeseo Integrated with Opera Acapella image analysis software Accelyrs Accord HTS With Pipeline Pilot Ohio Third Frontier Computing Systems
9
HTS Output is QUALITY DATA
10
Standard Screening Procedure 1 o HTS hits Triplicate assay confirmed HTS hits 10 point dose-response assay EC 50
11
HTS Assay Examples Receptor-binding GPCR Enzyme protease, kinase, phosphatase, lipase, others Bacterial growth Cell-based reporter gene Cell growth, cell viability Cytochrome P 450 inhibition Protein binding Protein production by cells ELISA
12
HIGH-THROUGHPUT SCREENING Examples of Assays: HIGH-THROUGHPUT SCREENING
13
Results from Enzyme Inhibition Screen 11,500 compounds screened Normalized results shown Each tile shows 1 plate of data Right: Color Scale for Normalization Distribution of compound % Activity
14
Results from 1 plate in Enzyme Inhibition Screen
15
High Content Screening With the Evotec Opera 96-, 384-, and 1536-well plates Up to ~ 70 images per well in 384-well plate
16
Internalisation Assay Example Image
17
Internalisation Assay Example Image Analysis
18
Internalisation Assay Example Opera External Data output Excel spreadsheet spots / cell cell area nuclei area
19
High Throughput & High Content Screening Services Quality Data Experienced Scientists State-of-the Art Equipment
20
Contacts Sandra Nelson High Throughput & High Content Screening sandra.nelson@uc.edu 558-2372 Ruben Papoian Drug Discovery ruben.papoian@uc.edu 558-0516 Charles McOsker Business Development & External Relations charles.mcosker@uc.edu 558-2569