Ventilation for Confined Spaces. 1910.146 requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated.

Similar presentations


Presentation on theme: "Ventilation for Confined Spaces. 1910.146 requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated."— Presentation transcript:

1 Ventilation for Confined Spaces

2 1910.146 requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated any hazardous atmosphere The forced air ventilation shall be so directed as to ventilate the immediate areas where an employee is or will be present within the space and shall continue until all employees have left the space.

3 The air supply for the forced air ventilation shall be from a clean source and may not increase the hazards in the space.

4 The atmosphere within the space shall be periodically tested as necessary to ensure that the continuous forced air ventilation is preventing the accumulation of a hazardous atmosphere.

5 Types of Ventilation Natural ventilation Mechanical supply ventilation (positive pressure) Mechanical exhausting (negative pressure)

6 Natural Ventilation Natural air currents Advantages Quiet Does not require power Not a source of ignition Maintenance free Disadvantages Highly unpredictable Very inefficient

7 Mechanical Supply Forcing fresh air in / contaminated air out Should be at a minimum rate of 20 air changes per hour Advantages Very effective in managing hazards Eliminates gas seeping back into the space Prevents flammable gas from being drawn across the fan motor Disadvantages Fan noise Stirring up dust

8 Mechanical Exhausting Pulls contaminated air out / draws fresh air in Works best when air intake is close to work area Advantages Pulls heavier than air contaminates from low areas Disadvantages May not create sufficient air movement Fan noise May draw flammable gases across the fan motor Supply ventilation can force air into the space 30 x the distance exhaust can draw it

9 Ventilation Factors Job details Atmospheric hazard Size of space Contaminants density How fast its created How much space is available for vent. Equipment Airflow required 20 air changes per hour Volume required

10 Ventilation Factors Breeze to ensure comfort Duct friction loss Can reduce air flow over 50% in 15 foot of duct Fan performance Design, Weight, Sound, Power

11 Supply Ventilation Directions Position fan 4-6 feet from entry with intake into wind Vertical spaces Position hose ¾ of the distance to the bottom, and no more than 15 feet from the work area Horizontal spaces Lay hose on the floor with the end within 10 feet of the far wall Turn fan on before placing duct into the space Ensure that there is no “short circuiting”

12 Exhaust Ventilation Directions Keep the duct 3 feet from the worker Position duct 1 foot from contaminant and 1 foot below the worker breathing zone Position so exhaust is out of wind and exhausted air is not pulled back into space If explosive, do not allow air to contact fan motor. Unit should be grounded Area around fan should be considered hazardous

13 In all Cases Ventilation should continue while space is occupied Prevent recirculation of exhaust air If LEL reading is present, remove hose before the fan is turned off

14 Lighter Than Air Gases

15 Heavier Than Air Gases

16 Special Situations

17 Below Grade Conditions