Presentation is loading. Please wait.

Presentation is loading. Please wait.

NZM Interface Module for SmartWire-DT

Similar presentations


Presentation on theme: "NZM Interface Module for SmartWire-DT"— Presentation transcript:

1 NZM Interface Module for SmartWire-DT
Monitoring and Control of Circuit Breakers by using the NZM-XSWD-704 module

2 The Speaker Rainer Menden Dipl.-Ing. Product Manager and Support
Communication Circuit Breakers

3 NZM circuit breakers - Communication
PROFIBUS-DP Modbus RTU DeviceNet CAN XSWD-704 NZM 2/3/4 XDMI-612 XMC-S0 PKE RMQ XMC-MB XPC-Soft Field bus Interface SWD-Communication Energy Metering

4 NZM as a SWD component in a switchboard
RMQ Base Contactor / Motor protection circuit I/O Modul Round cable RMQ Front Talking to: HMI Gateways - PROFIBUS,CAN -Ethernet IP -ModbusTCP - PROFINET -PROFINET -Ethercat 4

5 Areas of Application Function Benefits
Energy distribution in buildings and industry Function Benefits Detection of load peaks -> Optimization of power consumption Remote control -> Fast reaction time Fault diagnosis -> Prevention of faults Power metering -> Cost optimization Connection to SCADA systems -> Optimized system control OEM Customers who use SWD

6 Areas of Application Motor Protection – NZM and PKZ as Partners on SmartWire
OEM Customers who use SWD 12A A A >65A Total range of motor protection controlled by one network

7 Function Overview NZM 2/3/4 SWD Field bus Control level
Circuit Breaker SCADA level Status Currents Load Warnings Cause of Trip Settings NZM Coding Remote Control ON/OFF Energy counter Value Reset

8 Connection cable to NZM is part of NZM-XSWD-704
I/O Interfaces of 704 SmartWire-DT Optional connections Energy measuring device with pulse output S0 Status of breaker Opened/closed/tripped Energy impulses XMC-S0 Motor Operator Connection cable to NZM is part of NZM-XSWD-704

9 Data Organization Z A cyclic acyclic 1 2
High flexibility through 4 selectable data profiles Additional acyclic access Z A cyclic acyclic Profile 1 3 byte 2 11 byte 3 15 byte 4 31 byte SWD Status NZM Status X Currents Energy values NZM set values (rotary switch) NZM breaker data (type,fuction,version) Index 1 2

10 Number of NZM stations PROFIBUS-DP: CANOpen: 1 2 3 4 42 11 8 4
Max.58 stations, 242 Byte/String Data profile 1 2 3 4 Number of XSWD-704 58 22 15 7 CANOpen: Max.99 stations, 128 Byte/String Data profile 1 2 3 4 Number of XSWD-704 42 11 8 4

11 SWD Assist: Online Diagnosis via PC
Online access via diagnostic interface of gateway SWD Gateway Read out of current configuration Display of process values Display of diagnosis messages Testing of SWD configuration without PLC

12 Available Sales Tools Flyer: FTP Server: Support:
How to Communicate with your Circuit Breaker SAP: GB FTP Server: ftp://ftp.moeller.net/CIRCUIT_BREAKER/KOMMUNIKATION/NZM_XSWD_704 Support: Rainer Menden Phone: Daniel Jansen Phone:

13


Download ppt "NZM Interface Module for SmartWire-DT"

Similar presentations


Ads by Google