Download presentation
Presentation is loading. Please wait.
Published byKristopher Fleming Modified over 9 years ago
2
Helicopter Data Acquisition System ECE 4522 Senior Design II
3
Team Members David Paul Aaron Hill Robert McInnis Jason Schemmel Dr. Rob King (Advisor) (Advisor)
4
Team Responsibilities Aaron Hill (Power) Power consumption, PCB layout, and documentation David Paul (Controls) Control circuit design and synchronization Jason Schemmel (Communications) Antenna simulation, transmitter/receiver research, PCB layout Robert McInnis (Communications) Robert McInnis (Communications) Signal conditioning, sampling, and data conversion
5
Helicopter
6
Design Explanation Hub Blade Pivot Nonlinear stiffness spring POT Strain Gauge
7
Design Explanation HUB PIVOT Strain Gage
8
Design Explanation Position Transducer Battery Pack Power Source 900 Mhz Transmitter 2:1 Mux 10 bit A/D Converter Wheatstone Bridge Amplifier Signal Conditioner Strain Gauge KEYPowerSignal EM Signal BASIC Stamp Microcontroller
9
Design Explanation Helicopter House Power 10 bit D/A Converter KEY Power Signal EM Signal Data Enable 900 MHz Receiver LaptopLaptop Internal Sensor Package DAQ PCMCIA BASIC Stamp Microcontroller 10 bit D/A Converter
10
Status - Complete Transmission / reception Data conversion Acquisition instrumentation Power supplies Dual signal multiplexing BASIC Stamp programming/implementation
11
Status – Incomplete PCB Software Strain Gauge Signal Conditioner Adequate noise filtration
12
Simulation Comparison Control Signal Channel 1 Channel 0 Simulated Signal 5V 0V 5V 0V
13
Simulation Comparison Sampling Rate Transmitted Signal Input Signal (3Hz) Simulated Input Signal
14
Problems Solutions 1.Encoder/Decoder was slowing our sampling rate 2.Transmission Scheme transmitting unwanted address bits @ 10 kbps (22 bits per packet) 300MHz 3.Error checking overkill 1.Implemented BASIC stamp for quick custom solution 2.Using 50 kbps @ 900 MHz scheme transmitting 2-10 bit packets 3.Parity checking performed by BASIC stamp
15
Problems Solutions 4.Multiplexor would not latch analog data for output 5.Overall system noise. 4.Used a dual D/A configuration with control logic tied to chip selects. 5.Each chip data sheet calls for different de-coupling capacitors, which will be utilized during PCB design stage.
16
PCB Design Receiver Schematic
17
PCB Design Used Microsim PC-Boards (P-SPICE) Encountered Node Limit (Shareware) Single sided Decided to use Express PCB –Included CAD software –Double sided –Quick turnaround
18
Technical Challenges Remaining Final PCB Layout with size consideration Noise filtration during testing Calibration of acquisition devices (i.e. strain gage)
19
Placement of Transmitter Package Size limitations of PCB board (6”x2.5”) Proposed position of final installation of Transmitter PCB board.
20
Placement of Transmitter Package Packaging can be up to 2.5 inches tall Package will be secured to rotor tightly to prevent our hard work from slinging away
21
Timeline JanuaryFebruaryMarchAprilMay Prototype DAQ Software Testing/ Tweaking PCB Fabrication Final Documen- tation Preliminary Design Review Final Design Review Preliminary Hardware Review
22
Future Improvements Implement remote transmitting on/off switch Battery reduction circuitry Graphical User Interface (GUI) Automated helicopter control system Eliminate D/A conversion, allow Computer to do any needed operations to data
23
Helicopter Data Acquisition System ECE 4522 Senior Design II The End
Similar presentations
© 2025 SlidePlayer.com. Inc.