Download presentation
Presentation is loading. Please wait.
Published byRosa Veronica White Modified over 9 years ago
1
Fire vs. Water Flow
2
What’s the best size for an “attack line?” Maximum flow Maximum mobility Speed-How fast and how much Ease of deployment and pickup Personnel available Water supply available Maximum flow Maximum mobility Speed-How fast and how much Ease of deployment and pickup Personnel available Water supply available What factors are the highest priority on your department? 1” ? 1 3 / 4 ” ? 11/2”?11/2”?11/2”?11/2”? 11/2”?11/2”?11/2”?11/2”? 2” ? 2 1 / 2 ” ?
3
Pump Pressure for 125 GPM 1¾” 1½” 1” 2½” 150 feet 452 psi 156 psi 136 psi 105 psi (100 psi nozzle pressure)
4
Larger Attack Hose Lines Equal... Higher initial attack flow capability Less friction loss Longer hose lay capability Using more of pumps capacity Higher initial attack flow capability Less friction loss Longer hose lay capability Using more of pumps capacity Higher Flows Equal... Quicker fire knockdown Personnel spend less time in “combat” More lives saved More property saved Quicker fire knockdown Personnel spend less time in “combat” More lives saved More property saved
5
Fire Ground Hydraulics? 120? 150? 175? 200? P.S.I.? GPM? Loss per 100 ft.? Hose Diameter? Elevation Loss? Device Loss? Pump Pressure? Nozzle pressure?
6
The Preconnect is always the first line off The first two lines down fight most of our fires Can they handle most anything our department is “normally” going to fight? The Preconnect is always the first line off The first two lines down fight most of our fires Can they handle most anything our department is “normally” going to fight? The Preconnect...
7
The Pre-Con 150 Play 150’ of 1¾” @ 150 psi = 150 GPM Works “ most ” of the time It’s the easiest and most often practiced Simplifies pump operation (only one pressure works) But... is it the right choice, THIS time?? 150’ of 1¾” @ 150 psi = 150 GPM Works “ most ” of the time It’s the easiest and most often practiced Simplifies pump operation (only one pressure works) But... is it the right choice, THIS time??
8
How will we handle 90% of our fires? 90% of our fires result in 10% of our losses however, however, 10% of our fires result in 90% of our losses! 90% of our fires result in 10% of our losses however, however, 10% of our fires result in 90% of our losses! I got it, Chief!!
9
Will we count it as a great “save”...... or a futile training exercise?
10
ISO Ratings Insurance Service Offices Grading of fire department’s capabilities and equipment For determining fire insurance premiums Not an application rate formula Insurance Service Offices Grading of fire department’s capabilities and equipment For determining fire insurance premiums Not an application rate formula
11
NFPA Water Supply Formulas For pre-planning water supply To determine total quantity of water needed For a single structure Or a group of buildings Type of construction Occupancy rating Exposures Refer to NFPA 1231 Suburban & Rural Water Supplies For pre-planning water supply To determine total quantity of water needed For a single structure Or a group of buildings Type of construction Occupancy rating Exposures Refer to NFPA 1231 Suburban & Rural Water Supplies
12
Iowa State University Formula GPM = L x W x H 100 100 GPM = L x W x H 100 100 Fire knockdown in 60 seconds or less Normally for enclosed areas Can be used in pre-planning water requirements for a building or room Fire knockdown in 60 seconds or less Normally for enclosed areas Can be used in pre-planning water requirements for a building or room L = Length W = Width H = Height L = Length W = Width H = Height
13
National Fire Academy Formula for Quick Size-up... GPM = L x W 3 3 Fire knockdown in 30 seconds or less Multiply GPM by number of floors involved Can be adjusted for actual % of involvement Choose appropriate size & number of attack lines based on GPM required & other situational factors GPM = L x W 3 3 Fire knockdown in 30 seconds or less Multiply GPM by number of floors involved Can be adjusted for actual % of involvement Choose appropriate size & number of attack lines based on GPM required & other situational factors L = Length W = Width L = Length W = Width
14
Formulas & Fire Loading of Structures... Iowa State University Formula Developed in the 1950’s Fire load mostly organic materials Ventilation tactics utilized less often Attack often from outside due to lack of breathing apparatus, protective clothing, & other safety equipment Iowa State University Formula Developed in the 1950’s Fire load mostly organic materials Ventilation tactics utilized less often Attack often from outside due to lack of breathing apparatus, protective clothing, & other safety equipment National Fire Academy Formula Current information Fire load contains more synthetics Synthetics produce more BTU’s per pound & increase smoke & noxious gas output Ventilation and interior attack tactics utilized Increased water flow required due to increased heat output
Similar presentations