GroundMed DAQ/DMS Training Coimbra 6-12-2011 Andre Quintino Duarte Anibal T. de Almeida Joao Fong
2
Summary 1. DAQ - Data Acquisition System 1.1. Hardware Installation 1.1.1. Devices’ Assemblage 1.1.2. Power Connections 1.1.3. Communication Connections 1.1.4. Sensors Connections 1.2. Software Installation 1.2.1. Software Configuration 1.2.2. Measuring Utility 2. DMS - Data Management System (NEW) 3. Further Development in Coimbra 4. Questions and Answers 5. Coimbra GroundMed facility visit
3
Info All information available at: www.isr.uc.pt/~groundmed
4
Info All information available at: www.isr.uc.pt/~groundmed
5
1. DAQ - Data Acquisition System
6
National Instruments cRIO 9074
7
1. DAQ - Data Acquisition System National Instruments cRIO 9074 NI 9217 NI 9219 NI 9871
8
1. DAQ - Data Acquisition System DAQ
9
1. DAQ - Data Acquisition System DAQ Brunata Thermal Meters Pyranometer Indoor/Outdoor Temperature Sensors Humidity Sensor Carlo Gavazzi Meters
10
1. DAQ - Data Acquisition System DAQDAQ DAQDAQ DAQ System DAQ System
11
1. DAQ - Data Acquisition System Septemes les Vallons, France DAQ System DAQ System DAQ System DAQ System DAQ System DAQ System DAQ System DAQ System DAQ System DAQ System DAQ System DAQ System DAQ System DAQ System DAQ System DAQ System Oradea, Romenia Coimbra, Portugal Benedikt, Slovenia Valencia, Spain Barcelona, Spain Padova, Italy Athens, Greece Internet DMS Serve r Ground Med WebSit e Ground Med WebSit e
12
1.1. Hardware Installation 1.1.1. Device’s Assemblage
13
1.1. Hardware Installation 1.1.1. Device’s Assemblage Coimbra
14
1.1. Hardware Installation 1.1.1. Device’s Assemblage Barcelona
15
1.1. Hardware Installation 1.1.2. Power Connections
16
1.1. Hardware Installation 1.1.3. Communication Connections
17
1.1. Hardware Installation 1.1.3. Communication Connections Important: - Create an RS-485 network; - Use shield cable with 2 twisted pairs; - Connect shield to ground; - Connect a 120Ω resistor on the edges of the network; - All the devices on the network must have different addresses; - The order is not important.
18
1.1. Hardware Installation 1.1.3. Communication Connections
19
1.1. Hardware Installation 1.1.4. Sensors Connections
20
1.1. Hardware Installation 1.1.4. Sensors Connections Sensors: - Indoor Temperature Sensor; - Outdoor Temperature Sensor; - Pyranometer; - 2x Brunata (Flow Sensor and 2 Temperature Sensors each); - Current Transformers; - Humidity Sensor (Optional).
21
1.1. Hardware Installation 1.1.4. Sensors Connections
22
1.1. Hardware Installation 1.1.4. Sensors Connections Important: - Don’t mix Brunata Temperature Sensors; Temperature Probes Brunata Display Unit
23
1.1. Hardware Installation 1.1.4. Sensors Connections Important: - Don’t mix Brunata flow sensors; Flow sensor Brunata Volume Meter
24
1.1. Hardware Installation 1.1.4. Sensors Connections Important: - Each Brunata Display Unit has one and only one Volume Meter. Brunata Volume Meter Brunata Display Unit
25
1.1. Hardware Installation 1.1.4. Sensors Connections
26
1.2. Software Installation
27
Download and Install in this order: 1. NI cRIO Drivers (about 1600MB)http://joule.ni.com:80/nidu/cds/view/p/id/2411/lang/e n; 2. RTAD Application Installer (about 10MB) http://zone.ni.com/devzone/cda/epd/p/id/5986;3. Asynchronous Message Communication (AMC) reference library (about 6MB) (Not required anymore) http://zone.ni.com/devzone/cda/epd/p/id/6091;4. Reference Library for Reading cRIO System Configuration Information (about 6MB) (Not required anymore)http://zone.ni.com/devzone/cda/epd/p/id/1717;5. GroundMed software from ISR available at: www.isr.uc.pt/~groundmed;6. GroundMed Configuration Utility;7. GroundMed Measurement Utility.
28
1.2.1. Software Configuration
29
1.2. Software Installation 1.2.1. Software Configuration Set cRIO Time Zone, Time & Date: 1. Load MAX (Measurement & Automation) on the computer;2. Click on Remote Systems, then the cRIO module available;3. On the right size, click below on Time Settings;4. Set your Time Zone, Date and Time;5. Click above on Save.
30
1.2. Software Installation 1.2.1. Software Configuration Demonstration
31
1.2. Software Installation 1.2.1. Software Configuration Run RT Application Deployment: Your cRIO Software to install 1) Press Settings under “Application Images”; 2) Browse to load the GroundMed downloaded image; 3) Press “Deploy”.
32
1.2. Software Installation 1.2.1. Software Configuration Demonstration
33
1.2. Software Installation 1.2.1. Software Configuration - 8 different demonstration sites Does this means 8 different software versions?
34
1.2. Software Installation 1.2.1. Software Configuration
35
1.2. Software Installation 1.2.1. Software Configuration
36
1.2. Software Installation 1.2.1. Software Configuration
37
1.2. Software Installation 1.2.2. Measuring Utility
38
1.2. Software Installation 1.2.2. Measuring Utility
39
1.2. Software Installation Demonstration
40
3. Further Development in Coimbra
42
NI 9472 - 8 Sourcing Digital Outputs; - 6 to 30V range. Finder Relay 20.21.9.024.4000 - 24V Coil Voltage; - 250V AC Rated Voltage.
43
3. Further Development in Coimbra
44
5. Coimbra GroundMed facility visit 4. Questions and Answers
45
5. Coimbra GroundMed facility visit Thank You Andre Quintino Duarte Anibal T. de Almeida Joao Fong