Download presentation
Presentation is loading. Please wait.
Published byDinah Hill Modified over 9 years ago
1
UPS series PROTECT 1.M Scalable UPS in n+x technology Modularity with double conversion UPS modules True sine wave - output
2
PROTECT 1. modular the new generation of uninterruptible power supplies (UPS)
3
PROTECT 1.M · Comparison to standard UPS systems PROTECT 1. modular provides PROTECT 1. modular Scalable single-phase & three-phase uninterruptible power supply (UPS)
4
PROTECT 1.M · UPS modules from 4 kVA up to 24 kVA Structure for UPS power module High Power reserves as a result of a max. 24 kVA total output High Safety reserves as a result of n+x technology Static bypass switch L1 L2 L3 Three phase or single phase connection with automatic recognition Independent UPS modules (no central control) slide-in types; suitable for rackmount
5
PROTECT 1.M · n + x Redundancy Capacity n+x parallel redundancy Higher reliability Easy to increase overall capacity Modules hot-swappable without any interruption
6
PROTECT 1.M · Technology double-conversion design ( true online ): Classification VFI ( acc. to IEC 62040 – 3 ) Resolves various power problems: Interruption Weakening Noise Surge Instant voltage drop Thunderbolt Transients changes Frequency changes VFI – technology ( IEC 62040 - 3 ) mains rectifier inverter battery load Static Bypass
7
PROTECT 1.M · UPS classes Publication by ZVEI: UPS Guide........... by additional lightning arrestors Voltage Phenomenon Time e. g. IEC UPS solution 62040-3 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Outage - blackouts Sags / brownouts Dynamic overvoltage Undervoltage Overvoltage Lightning Transients (Surge) Frequency variations Voltage distortion (Burst) Voltage harmonics > 10 ms continuous sporadic < 4 ms sporadic periodic continuous VFD Voltage + Frequency Dependent VI Voltage Independent VFI Voltage + Frequency Independent Classification 3 Offline Classification 2 LineInteractive Classification 1 (true) Online real Double- Conversion
8
PROTECT 1.M · Power connections INPUT Single phase & Three phase automatically self–recognize OUTPUT Single phase INPUT ( Load 70% ) 1ph~ 140 Vac – 300 Vac 3ph~ 242 Vac – 520 Vac OUTPUT 1ph~ 230 Vac ±2%
9
PROTECT 1.M · Operating LCD Display PT 1.M
10
PROTECT 1.M · Autonomy time table Power Battery Capacity Autonomy time > > Power 1Batter y Cabinet Autonomy time
11
PROTECT 1.M · Communication interface Expansible - AS/400 card (dry contacts) - SNMP card (with connector for additional temperature measurements and intelligent load switch) Dual monitoring interface