Presentation is loading. Please wait.

Presentation is loading. Please wait.

© 2009, EPG NV Confidential Business summary www.energyproducts.nl © 2009, EPG NVConfidential Business summary.

Similar presentations


Presentation on theme: "© 2009, EPG NV Confidential Business summary www.energyproducts.nl © 2009, EPG NVConfidential Business summary."— Presentation transcript:

1 © 2009, EPG NV Confidential Business summary www.energyproducts.nl © 2009, EPG NVConfidential Business summary

2 © 2009, EPG NV Confidential Business summary www.energyproducts.nl Natural heating panels With the launch of the Plezura natural heating solutions in 2009, EPG has set the landmark of an entire new product line of natural heating

3 © 2009, EPG NV Confidential Business summary www.energyproducts.nl Company profile Energy Products Group NV, a Belgian based company, is built upon the heritage of the former Dutch company Energyproducts BV (EP). EP sold the first infrared heating panels in 1997. During almost 10 years EP was part of the Scheuten Glas Group. End 2006 EPG acquired full ownership of EP. Following the acquisition EPG moved all activities from the Netherlands to Belgium. As from September 2008, EPG has set up its own factory and offices in Asper (near Gent, Belgium).

4 © 2009, EPG NV Confidential Business summary www.energyproducts.nl Our mission EPG goes far beyond being only a manufacturer of electric infrared heating panels. EPG believes infrared heating is fundamentally more energy efficient then convection heating: minimum 25%, in many cases +50%. Knowing that about 30% of the world energy consumption is heating and that 99% of the heating in the world is convectional heating. EPG products can make the world save 10% of energy.

5 © 2009, EPG NV Confidential Business summary www.energyproducts.nl

6 Natural heating: EPG unique viewpoint Human bodyBuilding physics = Nature element essential in our evolution Direct (sun): - type A IR - short wave Indirect (re-emission): - type C IR - long wave Different IR experience Short IR wave: - detection: eye - heating of the skin (only surface) - activating character Long IR wave: - detection: skin - heating of our body (penetration, expand of blood vessels) - relaxation character Wall in summer South side: re-emits absorbed heat anti -fungi / anti -bacteria North side: absorbs heat no reflection, cold feeling Infrared

7 © 2009, EPG NV Confidential Business summary www.energyproducts.nl ConvectionRadiation Maximum saving air temparture 21°C17°C 24% Q(metabolism)none depening on radiation property10% Q(direct IR)none depening on radiation property20% Q(indirect IR)limited depending on room/wall humidity condition10% temperature delta 3°C-4°C1°C 5% Isolationstandard depending on wall/floor condition5% zone heatingnone depending on room organisation30% Natural heating versus convection Infrared consumes 25% (to +50%) less primary energy than convection.

8 © 2009, EPG NV Confidential Business summary www.energyproducts.nl Modern evolution from radiation to convection 90/10 70/3050/50 20/80 10/90 90/10

9 © 2009, EPG NV Confidential Business summary www.energyproducts.nl Natural heating panel PLEZURA Product line - wall and/or ceiling panels - with or without flens

10 © 2009, EPG NV Confidential Business summary www.energyproducts.nl PRODUCT Kit Panel + thermostat Plug and heat system Plezura Panel to be installed Special products On customer demand LABEL White label EPG engine EPG label / MARKET Retail Limited product range Very sharp price setting ProfessionalMarket Wide product range Distributors margin OEM / ODM

11 © 2009, EPG NV Confidential Business summary www.energyproducts.nl Advantages of natural heating 1/ ‘Plezura’ - feeling 2/ Energy efficient 3/ Health / anti-allergic 4/ Low installation cost/ maintenance cost 5/ Safety 6/ Optimal space efficiency

12 © 2009, EPG NV Confidential Business summary www.energyproducts.nl 1/ The ‘Plezura’ feeling - ‘Plezura’ = ‘pleasant’ feeling - après-ski experience

13 © 2009, EPG NV Confidential Business summary www.energyproducts.nl 2/ Energy efficiency Conventional -> heating up the air (convection spreads the heated air in the room) DISADVANTAGES: unbalanced heating and very energy consuming Natural heating -> heating of the objects in the room ADVANTAGES: balanced heating and more energy efficient (saving between 25% and 50%)

14 © 2009, EPG NV Confidential Business summary www.energyproducts.nl 2/ Energy efficiency Conventionial -> 100 to 120 W/m² needed to obtain ideal roomtemperature (+/- 21°C) Natural heating -> 50 W/m² needed to obtain ideal roomtemperature (+/- 18°C)

15 © 2009, EPG NV Confidential Business summary www.energyproducts.nl 3/ Health benefits - no air circulation = anti-allergic - better bloodcirculation -relaxed feeling - …

16 © 2009, EPG NV Confidential Business summary www.energyproducts.nl 4/ Installation and maintenance cost Installation cost - no pipes, chimney, boiler,… Maintenance - zero maintenance cost

17 © 2009, EPG NV Confidential Business summary www.energyproducts.nl 5/ Safety Maximum safety guarantee by using 2 safety thermostats

18 © 2009, EPG NV Confidential Business summary www.energyproducts.nl 6/ Optimal space efficiency


Download ppt "© 2009, EPG NV Confidential Business summary www.energyproducts.nl © 2009, EPG NVConfidential Business summary."

Similar presentations


Ads by Google