Hydrology and Water Resources RG744 Institute of Space Technology December 11, 2013
2
Hydrometry is the science of water measurement It is measurement of flowing water per second (flow rate discharge) Measurement is required to develop hydrograph, mass curve, for flood warning, distribution of water among users, and determining seasonal variation in runoff Discharge = area x velocity Q = AV
3
Direct Area velocity Method Dilution techniques Electromagnetic Method Ultrasonic Method In-direct Hydraulic Structures Slope area method
4
Stage is defined as water surface elevation measured above a datum Continuous measurement of discharge is difficult whereas observation of stage is easy, inexpensive and continuous Simplest device for this purpose is a staff gage – scale graduated in feet or meters
5
Float Gage Recorder To record flow depth as a function of time
6
Often presented as Stage Hydrograph Depth (stage) vs. time Discharge hydrograph is not measured directly but inferred from the stage hydrograph
7
Relates stage to discharge Constructed by plotting measured discharge against stage Typically non-linear curves Rating Curves can be extrapolated
8
Variation of surface velocity across a river section and at different levels
9
In a deep stream subsection, the average velocity is estimated by the average of velocities measured 20% depth (0.2D) and 80% depth (0.8D) Average velocity for flow in a shallow subsection of a river is observed to be equivalent to the actual velocity measured at 0.6h depth from surface of water
10
Isovels: lines joining the points having equal velocity
12
Current meters (mechanical device) To measure the velocity at a point in the flow cross-section Rotates by the stream current with an angular velocity proportional to the stream velocity v = aN s + b Floats Floating object on the surface of a stream Measure distance ‘S’ it travels in time ‘t’ Surface velocity ‘V’ can be calculated using the relation: V = S/t Mean velocity can be determined by multiplying the surface velocity with a reduction coefficient
13
Involves measuring area of cross-section of a river at various sites called gaging sites velocity of flow through the cross-sectional area (by current meters or floats)
14
X-section area = depth at the i th segment * (1/2 width to the left + ½ width to the right) Stream Cross-section
15
Calculation of Discharge For 1 st and last segment
18
Also known as chemical method Depends on continuity principle applied to a tracer that’s allowed to mix completely with the flow C o = Initial tracer concentration (background concentration) C 1 = added concentration of tracer at section 1 C 2 = tracer concentration at section 2 downstream Q 1 = tracer injection rate Q= Stream discharge
20
Based on Faraday’s principle Large coil buried at the bottom of the channel carrying current I that produces a magnetic field Small voltage produced due to the flow of water is measured by electrodes Signal output E (millivolts) is found to be related to discharge Q as:
21
Basically area-velocity method Average velocity is measured using ultrasonic signals Transducers or sensors are used to send and receive ultrasonic signals
22
Transducer A sends an ultrasonic signal received at B and B sends a signal that’s received at A after elapse time t 1 and t 2 respectively, then t 1 = L/(C + v p ) t 2 = L/(C – v p ) Where: L = Length of path from A to B C = Velocity of sound in water v p = component of the flow velocity in the sound path = vcos θ v = average velocity at a height ‘h’ above the bed
23
Use the relationship between the flow discharge and depths at specified locations Depths are measured in the field Two broad classifications: Hydraulic Structures (weirs and flumes) Slope area method
24
These structures produce a unique control section in the flow At these structure discharge Q is a function of water surface elevation h at measured at a specified upstream location Q = f (h)(equation A)
25
Weirs 90 degree V-notch weir Sharp crested rectangular weir Sharp crested trapezoidal (Cipolletti) weir Flumes Parshall Flume Rectangular Flume Trapezoidal Flume U Flume
26
Weirs are structures which are inserted in the channel to measure flow Depth or "head" of the water is measured as water flows over a weir For weirs equation A becomes Q = K (h) n H = Head over the weir K and n = system constants depending on the geometry of the weir
27
90 degree V-Notch Weir Q = 2.49 (h) 2.48 Where: Q = flow in cubic feet per second h = head (depth of flow) above the notch invert (lowest point) in feet
28
Sharp-Crested Rectangular Weir Q = C w Lh 3/2 where: Q = flow h = head (depth of flow) above the weir Crest L = length of weir crest C w = weir coefficient
29
Other Shapes of Weir
30
Used for small stream flow measurements Device formed by constriction in the channel (narrowing in a channel or/and hump) Head is measured in the flume upstream of the throat When manufactured and installed according to the specification rating can be taken directly from published tables
31
Indirect determination of flood discharge Consists of estimating 3 basic factors 1. Area of average x-section in a longitudinal reach of channel of known length 2. Slope of the water surface in the same reach 3. Roughness of the streambed If the channel cross-section, slope, and roughness are known, flow can be estimated by: Manning Equation or Chezy Equation
32
Manning:V = R 2/3 s 1/2 n Chezy: V = C R 1/2 s 1/2 alsoC = R 1/6 n Q = VA Where: V = mean flow velocity R = Hydraulic Radius (cross-sectional area divided by the wetted perimeter) s = slope of the channel n = Manning roughness coefficient of the channel C = Chezy roughness coefficient Q = volumetric flow A = cross-sectional area
35
Calculate the discharge through a section where the stream has overflowed onto the floodplain and the dimensions of the water area as shown. For both sub-sections, S=0.005. In sub-section 1 n= 0.06 and in 2 n = 0.035.