Download presentation
Presentation is loading. Please wait.
Published byEthelbert Potter Modified over 9 years ago
1
Electrical Safety
2
Introduction Electricity is essential to modern life Some employees work with electricity directly Some indirectly Electricity is a serious workplace hazard Electricity can be productive and safe
3
Agenda Vocabulary Misconceptions and myths about electricity Electrical shock and other injuries Electrical hazards Electrical safety for maintenance and custodial employees Electrical safety for offices and classrooms
4
Vocabulary Voltage Low voltage High voltage Current Resistance Conductor Insulator Ohm’s law
5
Voltage Electromotive force Electrical potential energy –“Pressure” Measured in volts (V)
6
Low Voltage Electrical installations and electrical equipment operating or intended to operate on systems of 600 volts, nominal, or less. All work performed directly on or in proximity to such electrical installations, equipment, or systems.
7
High Voltage Electrical installations and electrical equipment operating or intended to operate on systems of more than 600 volts. All work performed directly on or in proximity to such electrical installations, equipment, or systems. Beyond the scope of this training.
8
Current The continuous movement of electrons past a given point Measured in amperes (amps) (A) –Sometimes the symbol “I” is used
9
Resistance Opposition to the movement of electrons Resistance is used for direct current Measured in ohms (Ω) “Impedance” is the proper term for alternating current –“Resistance” is commonly used
10
Conductor A person who collects tickets on trains A person who leads a orchestra, band, or choir
11
Conductor A substance or thing that allows electricity (or heat) to flow by passing energy from particle to particle Silver, copper, gold, aluminum
12
Insulator A barrier that wraps conductive materials to protective against electric shock A material with little or no conductive properties –High resistance Glass, rubber, mica, and some plastics
13
Ohm’s Law R = V / A One volt will cause a current of one ampere to flow through a conductor having the resistance of one ohm V = A * R
14
Ohm’s Law V (Volts) A (Amps) R (Ohms)
15
Electrical Misconceptions Electricity tends to go to ground –After it reaches ground, it disappears Ground serves as just one of the electrical loops that misdirected current can use to get back to the grounded power source
16
Misconception #2 If an electrical appliance or tool falls into a sink or tub of water, the item will short and trip the circuit breaker This may not happen because the sink or tub may be non-conductive and therefore not part of the loop to ground
17
Misconception #3 AC reverse polarity is not hazardous Many tools have switches in only one of the two conductors serving the item The switch is supposed to be on the “hot” conductor supplying he power
18
Myths About Electricity Electricity takes the path of least resistance Current will take any conductive paths, high or low resistance, in order to return to the source that provides it power Small amounts of current will flow through paths of high resistance
19
Myth #2 Double insulated power tools are doubly safe and will always provide safety Double insulated power tools can be hazardous if dropped into water Electrical current can flow out of the power tool into the water
20
Myth #3 It takes high voltage to kill; 120 volts AC is not dangerous Current is the culprit that kills Voltage is a factor in determining how much current will flow
21
Electrical Shock A sudden and accidental stimulation of the body’s nervous system by an electrical current Current will flow through the body when it becomes part of an electrical circuit
22
Electrical Shock Dynamics CurrentEffect 3+ mAShock 10+ mAMuscular contractions 30+ mARespiratory paralysis 50+ mAHeart paralysis (can be fatal) 100+ mAVentricular fibrillation (usually fatal) 200+ mAHeart clamps tight 1500+ mATissue and organs burn
23
Other Injuries Burns Falls Injuries when machinery starts suddenly
24
Electrical Burns Current passing through tissue generates extreme heat Skin damage at entry and exit Internal tissue damage Result from arcs or flashes Thermal burns from overheated wires or equipment or fires
25
Falls Initiated by a shock Muscles contract involuntarily Worker can lose balance and fall
26
Machinery Injuries Unexpected activation Shock Pinch Crush Shear
27
Electrical Hazards Bare conductors Insulation failure Equipment failure Static electricity Heating and overheating Electrical explosions
28
Bare Conductors Live overhead wires most common Working on rooftops Repair of electrical systems Capacitors
29
Insulation Failure Heat and elevated temperatures Moisture and humidity Mechanical damage Rodents, fungi Chemical incompatibility
30
Equipment Failure Older portable tools Energized housing Broken connections Wrongly replaced internal wiring Lack of grounding plug
31
Static Electricity Occurs when two different materials contact and then separate High voltage, low current Flammable liquids Lightning
32
Heating and Overheating Use of electricity results in heat Can cause accidental fires Burns out equipment –Equipment failure and ignition Hot surfaces
33
Electrical Explosions Rapid overheating from overcurrents Caused by short circuits, power surges, or lightning Heated contaminants in oil-filled breakers or transformers Capacitors subject to wrong polarity
34
Safety for Maintenance and Custodial Employees Qualified electrical workers Engineered protection Safety considerations Safe practices Lockout/tagout Personal protective equipment (PPE)
35
Qualified Electrical Workers A person, designated by the district, who by reason of experience or instruction has demonstrated familiarity with the operation to be performed and the hazards involved
36
Engineered Protection Insulation Grounding Circuit breakers Fuses Ground-fault circuit interrupters
37
Insulation Parts of electrical equipment coated with a low-conductive material Rubber mats to stand on Rubber gloves Insulated shoes
38
Grounding Protects from shock Safeguards against fire Protects against damage to electrical equipment
39
System Grounding One conductor of the circuit is intentionally connected to earth Protects against high voltage contact Stabilizes voltage in a system
40
Equipment Grounding Equipment grounded by a permanent and continuous connection or bond Provides a path for dangerous fault current to return to system ground Enables protective devices to operate
41
Circuit Breakers Guard against overloads of current Ensure current flow does not produce heat that causes temperature to rise to dangerous levels Break the current path Thermal Magnetic
42
Fuses Guard against overloads of current Ensure current flow does not produce heat that causes temperature to rise to dangerous levels Break the current path Melt when current exceeds a designated value
43
Ground-Fault Circuit Interrupters Fast-acting electrical device sensitive to very low levels of current imbalance due to flow to ground Reduces duration of a shock Not an overcurrent device like a circuit breaker or fuse
44
Types of GFCI Circuit-breaker type Receptacle type Permanently mounted type Portable type Cord connected type
45
Circuit-Breaker Type A direct replacement for a standard circuit breaker Installed in a panelboard Includes the functions of a standard circuit breaker Can protect an entire branch circuit with multiple outlets
46
Receptacle Type A direct replacement for a standard receptacle Protects one or more receptacle outlets Protects additional non-GFCI type receptacles connected “down stream” Very popular because of low cost
47
Permanently Mounted Type Mounted in an enclosure Designed to be permanently wired to the supply Frequently used around large commercial swimming pools or similar wet areas
48
Portable Type Designed to plug into existing non-GFCI protected outlets Contain one or more receptacle outlets protected by the GFCI module Easily transported from one location to another Approved for outdoor use –Some are listed as rainproof
49
Cord Connected Type Consists of an attachment plug which incorporates the GFCI module Protects the cord and any equipment attached to the cord Plug has non-standard appearance and is equipped with test and reset buttons
51
Safety Considerations Plan every job Consider what could go wrong Use proper tools –Procedures, drawings and related documents Isolate equipment from energy sources Identify hazards that may be present
52
Safety Considerations Isolate hazards Test every circuit, every conductor, every time before touching Use PPE, when necessary Do you have the skills, knowledge, tools, and experience to perform this work safely?
53
Safe Practices Qualified and authorized electrical technician Voltages and frequency should be identified so that proper precautions can be implemented Ratings of overcurrent protection chould be checked to determine adequate protection
54
Safe Practices Work on de-energized systems –Use buddy system for energized systems Never touch a bare conductor until a system has been de-energized and verified Enclose and lock all exposed conductors All removed grounding cables should be replaced as soon as possible
55
Safe Practices Cords should be inspected before using Repair or replace if defective All tools, equipment, and extension cords should be grounded Use nonconductive tape measures near energized equipment
56
Safe Practices Avoid working on electrical circuits or equipment while clothing and/or shoes are wet Wet floor areas should be covered by dry wood or rubber matting Remove rings, watches, keys, and other metal items before beginning work
57
Safe Practices Plug power equipment into wall receptacles with power switches in the off position Unplug equipment by grasping the plug Check receptacles for missing or damaged parts
58
Personal Protective Equipment Insulating gloves Insulating blankets Insulating sleeves Floor covering Safety helmets
59
Safety in Offices and Classrooms Outlets Cords Machinery
60
Outlets Do not overload outlets by using extension devices to increase the number of outlets at that socket
61
Cords Keep cables, cords, and plugs clean and in good repair Protect cords that cross aisles and walkways Extension cords are for temporary use only Extension cords must be 16 gauge or larger
62
Extension Cords Extension cords should not: –Be affixed to structures –Extend through walls, ceilings, and/or floors –Be placed under doors or floor coverings –Be subjected to physical or environmental damage
63
Multi-Outlet Strips Multi-outlet strips and surge protectors are not considered extension cords One multi-outlet strip should not be plugged into another
64
Machinery Report damaged or defective equipment –Request repair or replacement Unplug defective equipment Carry equipment by the base –Never by the cord Do not touch grounded metal parts
65
Summary Work environments depend on electricity Electrical hazards are in all environments Electrical safety requires effort