Presentation is loading. Please wait.

Presentation is loading. Please wait.

Status of the Polarized 3He Target

Similar presentations


Presentation on theme: "Status of the Polarized 3He Target"— Presentation transcript:

1 Status of the Polarized 3He Target
Patricia Aguar Bartolomé

2 Overview Magnetic Holding Field - Solenoid design
- Numerical calculations - Solenoid test Target Cell Preparation Measurement of Polarization - Mechanical rail system - External holding field Patricia Aguar Bartolomé

3 Magnetic Holding Field
Polarized targets require a magnetic holding field, B0, to provide a quantization axis. SOLENOID The strength and uniformity of the field play an important role in obtaining long polarization relaxation times. Depolarization effects due to field gradients should be smaller than the relaxation due to surface effects. Main constraints Produce magnetic holding field of 7G with a relative field gradient of cm-1 for 6 bars in the target cell area. Appropriate outer radius to fit inside the Crystal Ball detector. Target cell dimensions determine the inner radius. The outgoing particles have to pass the coil minimization of the wire thickness. Patricia Aguar Bartolomé

4 Magnetic Field Calculation
Numerical calculation of the field and gradients with a finite element code (FEMM) Geometric parameters for the solenoid Parameter Value Solenoid length 80 cm N0 windings 1457 Current 0.3 A Inner coil diameter 0.82 cm Outer coil diameter 0.83 cm Copper wire diameter 0.053 cm Coil wound on a CFK-tube with cross section of 82 x 1 mm2 and 120 cm length. B magnitude determined using the three axis magnetometer MAG-03 MS (Bartington Instruments Ltd.) Patricia Aguar Bartolomé

5 Solenoid Test Patricia Aguar Bartolomé

6 Target Cell Design 20 cm length and 6 cm diameter
Non-magnetic materials in order to avoid depolarization of the gas - Quartz glass cell coated with Cesium - Aluminum caps - 50 mm Mylar windows metalized with Aluminum 3He gas target (P = 6 bar) First tests with prototype are in process Patricia Aguar Bartolomé

7 First T1 Measurement With Uncoated Cell
Patricia Aguar Bartolomé

8 Measurement of Polarization
Mechanical rail system to transport the target cell from the center of the solenoid to the center of the external holding field 1) 2) 3) 4) Patricia Aguar Bartolomé

9 External Holding Field
Helmholtz coils needed to measure the polarization Parameter Value Coils diameter 160 cm Current 4 A N0 windings 150 Copper wire diameter 0.2 cm Patricia Aguar Bartolomé

10 Transporting Solenoid
Solenoid to bring the target cell from the center of the CB to the center of the Helmholtz coils. Parameter Value Solenoid length 40 cm N0 Windings 800 Current 0.3 A Inner coil diameter 0.82 cm Outer coil diameter 0.83 cm Copper wire diameter 0.053 cm Patricia Aguar Bartolomé

11 Summary and outlook Conclusions
A solenoid produced to provide the holding field for the 3He target was designed and tested First homogeneity measurements of the solenoid with the polarized gas give values of First measurement of T1 with uncoated cell gives 4h Future Fix the leak on the target cell prototype Measurement of T1 with coated cell Production of mechanical rail system Patricia Aguar Bartolomé


Download ppt "Status of the Polarized 3He Target"

Similar presentations


Ads by Google