Pressure Regulator Comparison What should your regulator do… REGULATE OR STRANGULATE?
3
How do you define a good regulator? By how little the actual downstream pressure deviates from the set point.
4
How the Test was done… Regulators purchased from Authorized Distributors Set at 30 psi Using city water averaging 95 PSI Downstream ball valve slowly opened to allow 6 gpm flow
5
Test #1 The Discount Regulator
6
Preset at 30 psi
7
Drops to about 7½ psi
8
Test #2 An Internationally known brand
9
Preset at 30 psi
10
Drops to 14 psi
11
Test #3 Plast-O-Matic spring loaded regulator
12
Preset at 30 psi
13
Drops to 23 psi
14
Test #4 Plast-O-Matic air loaded regulator & patented Stabilizer
15
Preset at 30 psi
16
Drops to 29.5 psi
17
Plast-O-Matic Regulators Better flow Less Drop-off from set pressure
Similar presentations