Download presentation
Presentation is loading. Please wait.
Published byAlyson Ross Modified over 9 years ago
1
PowerPoint File available: http://bl831.als.lbl.gov/ ~jamesh/powerpoint/ BNL_2011.ppt
2
Acknowledgements Ken Frankel Rick Donahue Howard Padmore Alastair MacDowell 8.3.1 creator: Tom Alber 8.3.1 PRT head: Jamie Cate Center for Structure of Membrane Proteins (PSI) Membrane Protein Expression Center II Center for HIV Accessory and Regulatory Complexes W. M. Keck Foundation Plexxikon, Inc. M D Anderson CRC University of California Berkeley University of California San Francisco National Science Foundation University of California Campus-Laboratory Collaboration Grant Henry Wheeler The Advanced Light Source is supported by the Director, Office of Science, Office of Basic Energy Sciences, Materials Sciences Division, of the US Department of Energy under contract No. DE-AC02-05CH11231 at Lawrence Berkeley National Laboratory.
3
The optimum wavelength for macromolecular crystallography Higher? or Lower?
4
Charged Particle Equilibrium (CPE) Johns, H. & Cunningham, J. (1974). The physics of radiology. Thomas Springfield, Illinois.
5
dose Johns, H. & Cunningham, J. (1974). The physics of radiology. Thomas Springfield, Illinois. ~1 cm at 1 MeV f NH Charged Particle Equilibrium (CPE)
6
satisfies CPE collimator crystal X-ray e-e- violates CPE Assume a spherical crystal…
7
is there a “problem” with violating CPE? ICRU report 31 “Average Energy Required to Produce an Ion Pair” (1979) for air: W ~ 30 eV/ion-pair yet, final ions are thermalized (<0.1 eV each) Where does 99% of the energy go? Answer: non-ionizing excitations
8
Secondary ionization e-e-
9
e-e- e-e- +
10
Excitation e-e-
11
e-e-
12
e-e-
14
ionizing interactions e-e- + Violating CPE: two kinds of “dose”? non-ionizing interactions ICRU report 36 “Microdosimetry” (1984)
15
Charged Particle Equilibrium (CPE) Johns, H. & Cunningham, J. (1974). The physics of radiology. Thomas Springfield, Illinois. skin not burned
16
Ionization track
17
particle transport simulation using MCNP collimator crystal X-ray
18
Where do photons go? beamstop Transmitted (98%) Protein 1A x-rays
19
Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) Protein 1A x-rays
20
Elastic scattering
22
Inelastic scattering e-e- +
23
Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) Protein 1A x-rays
24
Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) inelastic scattering (7%) Protein 1A x-rays
25
Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) inelastic scattering (7%) Protein 1A x-rays Re-emitted (99%)Absorbed (~0%)
26
Photoelectric absorption
27
e-e- +
28
Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) inelastic scattering (7%) Protein 1A x-rays Re-emitted (99%)Absorbed (~0%)
29
Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) inelastic scattering (7%)Photoelectric (87%) Protein 1A x-rays Re-emitted (99%)Absorbed (~0%)
30
Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) inelastic scattering (7%)Photoelectric (87%) Protein 1A x-rays Re-emitted (~0%)Absorbed (99%) Re-emitted (99%)Absorbed (~0%)
31
Fluorescence +
32
e-e- +
33
Auger emission +
34
++ e-e-
35
MCNP cuts off at 1 keV 1 MeV100 GJ/molMedical radiation therapy 100 keV10 GJ/molMedical imaging 10 keV1 GJ/molX-ray crystallography 1 keV100 MJ/molS and P K-edges 100 eV10 MJ/mol“water window” 10 eV1 MJ/molC≡C bond 1 eV100 kJ/molC-C bond, visible light 100 meV10 kJ/molhydrogen bond 10 meV1 kJ/molheat (~300 K)
36
bonding affects absorption Almkvist, et al. (2010)."K-edge XANES analysis of sulfur compounds: an investigation of the relative intensities using internal calibration", J. Sync. Rad. 17, 683-688. MCNP model
37
particle transport simulation using MCNP collimator crystal X-ray
38
dose reduction with 1 Å radiation Crystal diameter (µm) Dose capture fraction f NH ←???→ 1 keV e - pathlength
39
100 μm crystal vs energy Photon Energy Dose capture fraction 1 keV 10 keV 100 keV 1 MeV f NH
40
dose reduction vs energy Photon Energy Dose capture fraction 1 keV 10 keV 100 keV 1 MeV
41
2 variables Dose capture fraction
42
Critical escape diameter Photon Energy (eV) Crystal diameter (µm)
43
Critical escape diameter Photon Energy (eV) Crystal diameter (µm)
44
Critical escape diameter Photon Energy (eV) Crystal diameter (µm)
45
Critical escape diameter Photon Energy Crystal diameter (µm) 1 keV 10 keV 100 keV 1 MeV 10 MeV
46
Darwin’s Formula I(hkl)- photons/spot (fully-recorded) I beam - incident (photons/s/m 2 ) r e - classical electron radius (2.818x10 -15 m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = I beam r e 2 V xtal V cell λ 3 L ωV cell Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27, 315-333.
47
Darwin’s Formula I(hkl)- photons/spot (fully-recorded) I beam - incident (photons/s/m 2 ) r e - classical electron radius (2.818x10 -15 m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = I beam r e 2 V xtal V cell λ3 Lλ3 L ωV cell Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27, 315-333.
48
Darwin’s Formula I(hkl)- photons/spot (fully-recorded) I beam - incident (photons/s/m 2 ) r e - classical electron radius (2.818x10 -15 m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = I beam r e 2 V xtal V cell λ 3 L ωV cell Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27, 315-333.
49
Dose Formula dose- absorbed energy (Gy) I beam - incident (photons/s/μm 2 ) t exp - exposure time (s) λ- x-ray wavelength (in Å) dose ≈ I beam ·t exp λ2λ2 2000
50
Dose Formula D max - maximum dose (Gy) I beam - incident (photons/s/μm 2 ) t dataset - accumulated exposure time (s) λ- x-ray wavelength (in Å) D max ≈ I beam ·t dataset λ2λ2 2000
51
Dose Formula D max - maximum dose (Gy) I beam - incident (photons/s/μm 2 ) t dataset - accumulated exposure time (s) R- radius of crystal T en - transmission of a sphere ~ exp(-μ en ·2R) - density of crystal E ph - photon energy q e - electron charge D max = I beam ·t dataset 3q e E ph 4R (1-T en )
52
Darwin’s Formula I(hkl)- photons/spot (fully-recorded) I beam - incident (photons/s/m 2 ) r e - classical electron radius (2.818x10 -15 m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = I beam r e 2 V xtal V cell λ 3 L ωV cell Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27, 315-333.
53
Darwin’s Formula D max - maximum dose (kGy) t dataset - accumulated exposure (s) r e - classical electron radius (2.818x10 -15 m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = r e 2 V xtal V cell 2 λ L ωV cell D max t dataset Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27, 315-333.
54
Darwin’s Formula D max - maximum dose (kGy) r e - classical electron radius (2.818x10 -15 m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) 2π- rotation range (radians) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = r e 2 V xtal V cell 2 λ L 2πV cell D max Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27, 315-333.
55
Holton & Frankel (2010) Acta D 66 393-408.
57
Where: I DL - average damage-limited intensity (photons/hkl) at a given resolution 10 5 - converting R from μm to m, r e from m to Å, ρ from g/cm 3 to kg/m 3 and MGy to Gy r e - classical electron radius (2.818 x 10 -15 m/electron) h- Planck’s constant (6.626 x 10 -34 J∙s) c- speed of light (299792458 m/s) f decayed - fractional progress toward completely faded spots at end of data set ρ- density of crystal (~1.2 g/cm 3 ) R- radius of the spherical crystal (μm) λ- X-ray wavelength (Å) f NH - the Nave & Hill (2005) dose capture fraction (1 for large crystals) n ASU - number of proteins in the asymmetric unit M r - molecular weight of the protein (Daltons or g/mol) V M - Matthews’s coefficient (~2.4 Å 3 /Dalton) H- Howells’s criterion (10 MGy/Å) θ- Bragg angle a 2 - number-averaged squared structure factor per protein atom (electron 2 ) M a - number-averaged atomic weight of a protein atom (~7.1 Daltons) B- average (Wilson) temperature factor (Å 2 ) μ- attenuation coefficient of sphere material (m -1 ) μ en - mass energy-absorption coefficient of sphere material (m -1 ) Self-calibrated damage limit Holton & Frankel (2010) Acta D 66 393-408.
58
wavelength dependence crystal diameter (μm) Å Minimum size for complete data set f NH = 1
59
Where: I DL - average damage-limited intensity (photons/hkl) at a given resolution 10 5 - converting R from μm to m, r e from m to Å, ρ from g/cm 3 to kg/m 3 and MGy to Gy r e - classical electron radius (2.818 x 10 -15 m/electron) h- Planck’s constant (6.626 x 10 -34 J∙s) c- speed of light (299792458 m/s) f decayed - fractional progress toward completely faded spots at end of data set ρ- density of crystal (~1.2 g/cm 3 ) R- radius of the spherical crystal (μm) λ- X-ray wavelength (Å) f NH - the Nave & Hill (2005) dose capture fraction (1 for large crystals) n ASU - number of proteins in the asymmetric unit M r - molecular weight of the protein (Daltons or g/mol) V M - Matthews’s coefficient (~2.4 Å 3 /Dalton) H- Howells’s criterion (10 MGy/Å) θ- Bragg angle a 2 - number-averaged squared structure factor per protein atom (electron 2 ) M a - number-averaged atomic weight of a protein atom (~7.1 Daltons) B- average (Wilson) temperature factor (Å 2 ) μ- attenuation coefficient of sphere material (m -1 ) μ en - mass energy-absorption coefficient of sphere material (m -1 ) Self-calibrated damage limit Holton & Frankel (2010) Acta D 66 393-408.
60
wavelength dependence crystal diameter (μm) Å Minimum size for complete data set
61
wavelength dependence crystal diameter (μm) Å Minimum size for complete data set
62
wavelength dependence crystal diameter (μm) Å Å Minimum size for complete data set
63
molecular weight crystal diameter (μm) 100 Da 1 kDa 10 kDa 100 kDa 1 MDa 10 MDa Minimum size for complete data set 1 Å X-rays 2 Å spots B = 24 50% solvent
64
Prediction: Exploiting Nave-Hill effect will require multi-crystal datasets
65
Other reasons for high energy room temperature
67
Zero-parallax microscope pinhole mirror microscope
68
High energy compresses pattern 2 Å data
69
Example Room-temperature Data lysozyme 50 μm beam 37 Gy/s (0.775 Å) 30s exposures at 20C 90° of data, 97% complete I/ = 1.5 at 1.9 Å R merge 18% (overall) 5% (low) ΔB same as 20 min at 100K B factor -2 -4 -6 scale vs batch 210210
70
high energy myth: less background elastic background/spot intensity ratio is wavelength-independent!
71
photon energy (eV) normalized figure of merit obliquity effect
72
high energy myth: less background elastic background/spot intensity ratio is wavelength-independent! However: inelastic and fluorescence are less, as is absorption
73
Other reasons for high energy room temperature high pressure?
74
Room temperature damage rates dose rate (kGy/s) dose at half intensity (MGy)
75
Room temperature damage rates dose rate (kGy/s) dose at half intensity (MGy)
76
Room temperature damage has a size dependence?
77
Radiation Damage “scale factor” F 2 alone cannot explain change in overall scale!
78
Darwin’s Formula I(hkl)- photons/spot (fully-recorded) I beam - incident (photons/s/m 2 ) r e - classical electron radius (2.818x10 -15 m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) C. G. Darwin (1914) P A | F(hkl) | 2 I(hkl) = I beam r e 2 V xtal V cell λ 3 L ωV cell
79
“scale factor” implies that damaging motions are larger than unit cell Room temperature damage has a size dependence? high pressure will hold it together? suggests micro-fracture mechanism of spot fading
80
Radiation Damage prediction large displacements cannot be faster than the speed of sound
81
Timescales of radiation damage Garret et. al. (2005) Chem. Rev. 105, 355-389
82
Two types of reactions Garret et. al. (2005) Chem. Rev. 105, 355-389 nonhomogeneous homogeneous
83
Timescales of radiation damage Garret et. al. (2005) Chem. Rev. 105, 355-389 LCLS ALS bunch
84
Room temperature damage rates dose rate (kGy/s) dose at half intensity (MGy)
85
Room temperature damage rates dose rate (kGy/s) dose at half intensity (MGy)
86
Nozzle ground to provide large X-ray diffraction angle Droplets freeze at 10 6 o /sec. in vacuum to vitreous ice if cryoprotectant added. Hand-grinding to micron gives large take-off angle for X-rays ! D. DePonte X-rays 5 microns Flow rate 12 microliters per minute. An environmental SEM image of operating protein-beam injector for LCLS.
87
What about very low energy?
88
sample shadow on detector Cu
89
sample shadow on detector
90
X-ray of cryo stream
91
low-energy X-rays Cu λ=2d sinθ 2.5 Å data with 5 Å X-rays International Tables for Crystallography, Vol. C, 2nd ed., chapter 6.3
92
Detector d = 2.5 Å sample injector Mirrors λ = 5 Å d = 2.5 Å h,k,l -h,-k,-l Colliding Beam Anomalous Measurement
93
0 20 40 60 80 100 Anomalous differences are resilient to non-isomorphism R iso (%) 1.0 0.8 0.6 0.4 0.2 0 Correlation Coefficient of ΔF ano 100 x 100 lysozyme PDBs
94
The optimum wavelength for macromolecular crystallography Maximize data/damage→15-50 keV Turn the crank → 12.68 keV Native element phasing→ 2-2.5 keV the future: multi-crystal data sets
95
PowerPoint File available: http://bl831.als.lbl.gov/ ~jamesh/powerpoint/ BNL_2011.ppt
Similar presentations
© 2025 SlidePlayer.com. Inc.