Download presentation
Presentation is loading. Please wait.
Published byAlicia Edwards Modified over 9 years ago
1
Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006
2
Jan. 2006 R&M range_connectors for field termination / Page 2 Why a pre-polished connector for field termination LAN ENVIRONMENT Mid/low number of FO connectors Terminations mostly on break-out cable Short links, limited testing equipments (power meter very seldom OTDR) Good, reliable, quick connections LAN INSTALLERS Mid/low experience with FO termination Manual skill not improvable because of termination quantity/frequency Limited tools and consumable availability
3
Jan. 2006 R&M range_connectors for field termination / Page 3 Cost Connector with very limited tools and no consumable Very fast and secure termination No scrap for termination and polishing errors No need or very limited training Quality Factory polished and tested connector gives better performance Suitable for all LAN applications where APC is not required (CATV) Must to meet Standard requirement for APC, SPC, UPC Why a pre-polished connector for field termination
4
Jan. 2006 R&M range_connectors for field termination / Page 4 Pre-polished connector for field termination Functional parts prepolished fiber stub coupling medium (index mating gel) Ceramic ferrule with factory polished end face The upper part of the plug is opened with a "wedge" (here not shown). This opens the space to introduce a field stripped and cleaved fiber from the rear. Closing the upper part the fiber will be fixed and hold in place.
5
Jan. 2006 R&M range_connectors for field termination / Page 5 Connectors for field termination Ceramic ferrule Factory polished tip Reliable and proved technology Low insertion loss > 500 mating cycles Connector surface inspected Commonality through various types same tools same installation technique Features Construction of the connector ferrulefield fiber Mechanical Splice
6
Jan. 2006 R&M range_connectors for field termination / Page 6 Connectors range for field termination Functional specifications Compatible with customary SC, LC, ST Low insertion loss ( < 0.5dB ) Multimode and Singlemode fibers For 50/125 and 62.5/125 Suitable for Mini-Breakout cables (900µm) and breakout cables up to 3mm Ø (SC, ST) SC LC ST
7
Jan. 2006 R&M range_connectors for field termination / Page 7 Connectors for field termination Features Easy handling Light and compact design Power supply independent Three tools in one kit (SC, LC and ST) Suitable for solid and dry tight buffer Standard Tool Kit Crimping tools Fiber cleaver Tweezers Jacket stripper Primary coating stripper Secondary coating stripper Length gauge Kevlar scissors Ferrules crimping aid Alcohol wipes and adhesive tape Instruction manual Supply
8
Jan. 2006 R&M range_connectors for field termination / Page 8 Connectors for field termination Optional components for Standard Tool Kit Continuity Test System CTS CTS (Continuity Test System) allows to check the quality of fiber splice. Light is not be visible in the cam area if splice action is successfully completed. If light is visible, splice procedure must be repeated from beginning to ensure optimum installation. Red light source Standard Patch- Cord Crimp tool Connector adapters
9
Jan. 2006 R&M range_connectors for field termination / Page 9 SC-RJ – the smallest in its class September 2005
10
Jan. 2006 R&M range_connectors for field termination / Page 10 SC-RJ talents the smallest SC-Duplex fiber optic connector (SFF) with a unique mechanical security system for data, audio and video communication with a high and reliable performance suitable for any F.O. technology
11
Jan. 2006 R&M range_connectors for field termination / Page 11 SC-RJ adapter standardization ed in EN50377-6 Plug standardized in EN50377-6 work item for IEC IEC 61754-x Adapter standardized in EN50377-6 Suitable for any standard Simplex SC connector
12
Jan. 2006 R&M range_connectors for field termination / Page 12 SC-RJ can take them all Singlemode (SM)Multimode (MM)
13
Jan. 2006 R&M range_connectors for field termination / Page 13 SC-RJ connector Characteristics - Push-Pull-System - 2,5 mm Ceramic precision-ferrule (metallic for POF only) - Low insertion loss - Polarized - Field terminable - Color coding on both sides (8 colors)
14
Jan. 2006 R&M range_connectors for field termination / Page 14 SC-RJ Adapter Characteristics - Fits in all R&M RJ45-cut outs - Precision PhBr sleeves for multimode - Precision ceramic sleeves for singlemode - SC-Simplex compatible
15
Jan. 2006 R&M range_connectors for field termination / Page 15 SC-RJ tests and performance - optical Multimode (OM2)Singlemode (OS1)SI-POF (980/1000)Standard Test Wavelength 1300 nm 30 nm1310 nm 30 nm660 nm 30 nm Type of cableI-V(ZN)H I-V 2YDIN/VDE Optical Attenuation EN 61300-3-34 Max.0,75 dB0,80 dB 95% 0,50 dB 0,60 dB n.a. Mean. 0,35 dB 0,30 dB 0,40 dB Return loss 20 dBClass R: 40 dB n.a.EN 61300-3-6
16
Jan. 2006 R&M range_connectors for field termination / Page 16 SC-RJ tests and performance - mechanical Multimode (OM2)Singlemode (OS1)SI-POF (980/1000)Standard Test Wavelength 1300 nm 30 nm1310 nm 30 nm660 nm 30 nm Mechanical Strength of coupling mechanism EN 61300-2-6 Load40 N Duration of the load1 min2 min1 min Mating durability EN 61300-2-2 Number of cycles500 Vibration (sinusoidal) EN 61300-2-1 Octave/min10 - 55 Hz 10 - 500 Hz Amplitude0,75 mm 0,35 mm Impact EN 61300-2-12 Number of drops555 Drop height1,5 m Cable retention connector EN 61300-2-4 Tensile force100 N 50 N Duration2 min
17
Jan. 2006 R&M range_connectors for field termination / Page 17 SC-RJ tests and performance - environmental Multimode (OM2)Singlemode (OS1)SI-POF (980/1000)Standard Test Wavelength 1300 nm 30 nm1310 nm 30 nm660 nm 30 nm Environmental Cold EN 61300-2-17 Temperature - 10 °C- 25 °C - 10 °C Duration96 h Dry heat EN 61300-2-18 Temperature+ 60 °C+ 70 °C+ 60 °C Duration96 h Damp heat (steady state) EN 61300-2-19 Temperature+ 40 °C Duration96 h relative humidity 93 % Change of temperature- 10 °C / + 60 °C- 25 °C / + 70 °C- 10 °C / + 60 °C EN 61300-2-22 Temperature- 10 °C / + 60 °C- 25 °C / + 70 °C- 10 °C / + 60 °C Duration at max. temperature1 h Attenuation change for all tests passed Attenuation 0,20 dB Wavelength 1300nm1550nm
18
Jan. 2006 R&M range_connectors for field termination / Page 18 Applications : patch cords R&M patch cords are delivered with color clips defining the type of fiber. Fiber definition 62.5/125 (OM1)→anthracite 50/125 (OM2)→ orange 50/125 (OM3)→ turquoise 9/125 (OS1)→ blue or green 980/1000 → yellow 200/230→ violet
19
Jan. 2006 R&M range_connectors for field termination / Page 19 With mounting plate for flexible mounting in one channel holders in - 19” patch panel - WM box - WM outlet - FM outlet - Consolidation point- One channel module holder Applications : terminal outlets and patch panels
20
Jan. 2006 R&M range_connectors for field termination / Page 20 Applications : 19” patch panels direct (one channel holder) and by fiberliner 1U Patch panel 3U patch panel 16 Port (32 fibers) 12 Port (24 fibers) 60 Port (120 fibers) - splice version - for preassembled cables - field termination
21
Jan. 2006 R&M range_connectors for field termination / Page 21 Applications : 24 port patch panel Snap-In Extra adapter frame for flexible mounting in any materials One frame for two mounting surface thicknesses Including color coding (8 colors)
22
Jan. 2006 R&M range_connectors for field termination / Page 22 SC-RJ Snap-In Easy, fast and reusable, flexible Flexible mounting in hole pattern 14.9 mm x 19.5 mm in materials with wall thickness 1.5 mm or 2.0 mm 1.52.0
23
Jan. 2006 R&M range_connectors for field termination / Page 23 Applications : for Snap-In 19" 1HE 24 Port Patch Panel for max. 24 adapters (48 fibers!) Snap-In SC-RJ SM, MM and POF Snap-In E-2000 Compact for SM and MM Or combined with RJ45 connection modules
24
Jan. 2006 R&M range_connectors for field termination / Page 24 Applications : P.C.B. mounted for Active Components
25
Jan. 2006 R&M range_connectors for field termination / Page 25 Security level 1 Visual color coding -On connector and coding frame -8 different colors blue, green, red, orange, anthracite, violet, yellow, turquoise Security level 3 Mechanical plug-IN protection – adapter guard protection against inadvertently connection -Key to unlock adapter guard Mechanical plug-OUT protection -fiber guard – protection against inadvertently disconnection -Key to unlock fiber guard Applications : Security options
26
Jan. 2006 R&M range_connectors for field termination / Page 26 Expanding connectors choice with pigtail assembly When connectors performance are extremely demanding, pigtails for mechanical or fusion splice offer the best value For single mode installation For APC finishing For termination of out of size cables For economic and quick installation